0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B
0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 6 VN-OMP0001 VNC VNC VNC VNC VNH VNH VNH VNH / / / / 1 DC AC VT307 12(P1) 12(P1) 12(P1) 12(P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) Air operated Solenoid Port VNC02 12 (P1) External pilot Bleed port External pilot 10 (P2) Bleed port External pilot Pilot exhaust Ass Ass Ass Ass y y y y VNH VNH VNH VNH () 3 3 3 3
Direct installation For direct mounting, use M3 screws (2 pcs.) or equivalent. The recommended tightening torque of the screw is 0.5 to 0.7 Nm. Mount the product on a flat and even surface. Mounting on an uneven surface can damage the case. Screws and washers should be supplied by the user.
Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 21 - How to Mount Air Gripper (1)Mounting orientation: On robot arm(s) (2)Mounting to the cover Take care not to get the switch cable caught when mounting the cover.
Reference data Units: mm IDH6 Jumper cord 7 6 5 4 3 1 PE Remote start/stop Fault-signal (N.O: Close at "Fault") Fault-signal (N.C: Open at "Fault") 1042 31 N 2 L Operation-signal (N.O) Ground Terminal screw: M3 Suitable wire: 1.25mm or more 2 244 Power supply Connector width: 6.5mm or less Detail of wiring 35 184 172 392 (Note) 15 80 223 321 3001 485 The type without built-in filter does
Piping to products When piping to a product, avoid mistakes regarding the supply port, etc. 1) When using SMCs M3 or M5 fittings, follow the procedures below to tighten them. Mounting Connection thread: M3 1. Operation manual Warning First, tighten by hand, then use a suitable wrench to tighten the hexagonal portion of the body an additional 1/4 turn.
Replacement procedure of shock absorber Loosen the hexagon socket head set screw (M3) at the piston rod by approximately one turn, and push down the lever. (See Fig. 11) Tool Hexagon wrench: Width across flats 1.5mm While pushing down the lever, remove the shock absorber and replace it with a new shock absorber. Tighten the hexagon socket head set screw (M3 x 0.5) of the piston rod.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4x20) with washer, 1 pc.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED and switch LED display to indicate the status of the SI unit 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.
Round head screw (M3 x 8) 4 pcs. EX600-ZMV2 (Specialized for the SY series) Enclosed parts: Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 2 pcs. -103No.EX-OMU0028-D 3.
(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.
Match polarity between solenoid valve and SI unit output. -30No.EX-OMW0016-A Maintenance Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the solenoid valve manifold. Replace the SI unit.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 2 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tithe screw (4x14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18 20 PSE54(A)-IM5 PSE54(A)-IM5H -14No.PS-OMG0004-D Revision history A: For B: Complete revision C: Limited warranty and Disclaimer and measurement laws are added.
Round head screw (M3 x 8) 4 pcs. EX600-ZMV2 (Specialized for the SY series) Enclosed parts: Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 2 pcs. -114No.EX-OMW0006-D 3.
Panel mount adapter ZS-26-B With set screw M3 x 8L (2 pcs.) and waterproof seal Panel mount adapter + Front protective cover ZS-26-C With set screw M3 x 8L (2 pcs.) and waterproof seal Front protective cover ZS-26-01 48 conversion adapter ZS-26-D It is an adapter for attaching PSE200A series in the panel cut size of PSE100 series. -8No.PS-OMW0005-C Summary of Product parts Names of individual