500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100
It is set to these values when delivered. 2.1 Communication Procedure This product receives a request message from the master computer and sends back a corresponding response message. It does not send a message firstly.
-A-20 CH1) 8.5.2 HRL200-A-20 CH1 0.6 60 Circulating fluid outlet 0.5 50 Lifting head [m] 0.4 40 Pressure [MPa] 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Circulating fluid flow[L/min] Fig. 8-10 Pump capacity(HRL200-A-20 CH1) HRL Series Documents 8-9 HRX-OM-Y098 Chapter 8 Documents 8.5.3 HRL300A20 CH1 0.7 70 Circulating
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
) IN OUT 01 ARJ 3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Body size Option specifications 0.7MPa setting (standard) 0.2MPa setting With thread sealant Nil 1 S Model Relieving type 10 When set at 0.2MPa, a pressure gauge is not included.
Area: (800) 258-9200-www.stevenengineering.com HS A B 32/40/50 (mm) D-M9 V, D-F9 WV D-A9 V Auto switch model Symbol A B Hs A B Hs 12 16 20 25 32 40 50 17 19 22.5 24.5 27 30.5 36.5 0 0 3.5 5.5 5 7.5 10.5 1.5 2 6 7 8 12 10 19 21 24 26 29 32.5 42 4.5 4 7.5 9.5 9 11.5 14.5 5.5 6 10 11 12 16 14 Bore size (mm) HS A B Reed switch D-A7 D-A80 D-A73C D-A80C D-A79W Solid state switch D-F7V D-J79C D-F7WV
59 67 81 84 L 52.5 59 67 81 84 LD LU 13 14 17 23 23 ZZ 116 127 138 171 175 LA 35 41 46 62 62 ZZ Model MUl25 MUl32 MUl40 MUl50 MUl63 lLC 18 22 26 32 32 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 CD-MU02 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 Dimensions L, Z, and ZZ are reference dimensions for installing a single knuckle joint, which may be used as a guide.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Refer to page 7-2-5. 2-M3 x 0.5 (Port size) M3 x 0.5 (Relief port: 10See above) (Vacuum port: 11See above) 3.5 20Data C + Stroke 3 B + Stroke A + Stroke Without auto switch With auto switch A B C A B C Bore size (mm) 24 18 29 23 11.5 16.5 6, 8, 10 7-2-7 7 Series CUJ Construction Double acting !3 w e q !1 r y o e t !
Bore size Stroke range head cap screw for Model Bracket CW CT CL CX CD M CZ R mounting pivot bracket (Accessory) Without auto switch With auto switch 15.5 20 25.5 28 15.5 20 25.5 28 4.5 4.5 6.6 6.6 4.5 4.5 6.6 6.6 M4 x 10 L M4 x 10 L M6 x 12 L M4 x 10 L M4 x 10 L M4 x 10 L M6 x 12 L M 6 x 12 L 5 6.5 8 10 5 6.5 8 10 5 to 30 5 to 30 5 to 50 5 to 50 5 to 30 5 to 30 5 to 50 5 to 50 14 15 18 20
5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/M9mW(V)/M9mA(V) 3 3 4.5 4.5 Values which include hysteresis
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
Note 2) The dimensions (A + stroke) and (B + stroke) for 10 mm stroke will be the same as those for 15 mm stroke.
Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.
Nil S n L Auto switch type Nil Without auto switch Cylinder bore size (stroke mm) Refer to the table below for auto switch part numbers. 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil F R Note 2) Standard With buffer With
4-7-17 2 Series VT325 Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) Weight Valve model Grommet Port size C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.
model that can provide a gripping force of 10 to 20 times the workpiece mass, or more.
97 67 1.5 65 1.5 123 105.5 25 3 (R) 3 (R) 1 (P) 1 (P) 25 17 2 4-1/4,3/8,1/2NPT 4-3/4NPT VH43 -N02/N03/N04 (Bottom porting) VH43 -N06 (Bottom porting) 2 (A) 2 (A) 46 54 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-3/4NPT 4-1/4,3/8,1/2NPT 9
Please change the parameter in the initial setting. *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 10 - LECSC LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter Para. No.