SMC Corporation of America
Elite Part Number Search
Search Results "AC40A-F03C-23-D"

U, D)-SSL1 Y VQ2000/4000/5000 EX123 (U, D)-SSL2 Y IP53 or NEMA12 comes as optional.

4.5 4.5 22 18 18 8 13 14 4.5 4.5 3.5 3.5 29 29 18 18 9 8 13 Reed auto switch D-A9V Solid state auto switch D-M9V D-M9WV D-F8 D A Figures in the table above are used as a reference when mounting the auto switches for stroke end detection.

MY CY Proper Auto Switch Mounting Position MG A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 24.5 93.5 -X CYP32 33 122 20Data Mounting of Auto Switch When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.

MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data

IODD file 1 D-MP025A/B/C SMC-D-MP025-ymmdd-IODD1.1 2 D-MP050A/B/C SMC-D-MP050-ymmdd-IODD1.1 3 D-MP100A/B/C SMC-D-MP100-ymmdd-IODD1.1 4 D-MP200A/B/C SMC-D-MP200-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.

GB MM CB CA D 0 0.3 0 0.3 BA BB NA A + 0.2 + 0.1 CX 0 0.3 U BA H S + Stroke Z + Stroke ZZ + Stroke R 0 0.3 BB (mm) CD (Cd) A BA BB CA CB CX D GA GB H MM NA NB R S U Z ZZ Bore size (mm) 10 15 17 14 3.3 3.2 4 8 18 28 M4 x 0.7 5 46 8 82 87 15 12 12.5 22.5 16 15 20 20 5 6.5 5 8 23 28 M5 x 0.8 8 47 10 85 93 18.3 18.3 12.5 27.5 Clevis pin and retaining ring are shipped together. 838 Stainless

Note 2) The figure shows an extended piston rod. 10-9-10 10 Heavy Duty Stopper Cylinder Series RSH/RS1H Proper Auto Switch Mounting Position Auto switch B A RE A B REC CX CY Proper Auto Switch Mounting Position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models MQQ M D-Y69 D-Y7PV D-Y7WV D-Y7BAL RHC Bore size (mm) A B A B A B MK(2) 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 RS

mounting style Rail mounting style 15 stroke 80 121 D-H7/H7W 15 60 10 30 stroke 88 140 Basic weight D-H7NF 45 stroke 98 164 D-C73C/C80C Note) 15 65 10 60 stroke 110 189 D-H7C Axial foot style 7 19 Mounting bracket weight D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F 10 Rod side flange style 5 13 5 Mounting nut and rod end nut are included in the basic

Note 2) The figure shows an extended piston rod. 10-9-10 10 Heavy Duty Stopper Cylinder Series RSH/RS1H Proper Auto Switch Mounting Position Auto switch B A RE A B REC CX CY Proper Auto Switch Mounting Position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models MQQ M D-Y69 D-Y7PV D-Y7WV D-Y7BAL Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office:

32 15 32 I 10 15 J 6 7 X 244 to 254 262 to 279 Y Note 2) I 10 15 J 6 7 X 233 to 244 224 to 241 Y Note 2) J 6 7 X 240 to 251 236 to 253 Y Note 2) H 298 339 H 323 352 I 10 15 15 32 15 32 15 32 589 to 614 633 to 673 564 to 589 542 to 581 579 to 605 571 to 610 MF -90 15 32 A G D Note 1) F D Note 1) D Note 1) F F Y C C C Y Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B

(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.

Piping port M5 x 0.8 GB BA CB D LH LB LY With head cover port in axial position (R) LT BB NB A NA X Y LX LZ S + Stroke Z + Stroke H 2-LC Mounting hole (mm) Bore size (mm) A BA BB CA CB D F GA GB H LB LC LH LT LX LY LZ MM NN NA NB S X Y Z 10 15 15 12 17 14 4 8 8 5 28 21.5 5.5 14 2.5 33 25 42 M4 x 0.7 M10 x 1.0 12.5 9.5 46 6 9 74 16 15 18 18 20 20 5 8 8 5 28 23 5.5 14 2.5 33 25 42 M5 x 0.8

Make sure to download the parameters by following the procedure "d) Parameter writing to the controller" shown below to write the parameters to the controller. d) Writing Parameters to the controller To write the parameters to the controller, select the Download button in the Parameter window.

Current limit is exceeded (1-148) Input RESETSV ON D Remove the obstructions while the actuator moves.

to 105 CKZ80-42 3680N-R D E F 30 to 105 For mounting bolt, a hexagon socket head cap screw and a spring washer No. 2 are recommended.

P.336 P.1785 (/) (/) 19 18-2. 12 16 20 25 32 40 50 63 80 100 1 2 1 2 1 15 2 15 1 15 2 15 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 10 15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.

Printed in Japan. 1st printing May, 2000 D-SMC.L.A. P-80 (D)

1 1 DO DlN terminal, without connector 1 4 11 4 70 G Grommet, 300mm lead wire 1 H 50 Grommet, 600mm lead wire 11 4 2 90 70 E Grommet terminal 2 T Conduit terminal 90 D DlN connector Body ported VEX3 12 0 01 5 D B Base mounted VEX3 22 0 01 5 D B B Bracket (Except VEX332) Option 0 Air operated Operation F Foot (Only VEX312, VEX332) 1 External pilot solenoid N Silencer for pilot exhaust (P2)

SFOD-OMT0009) d) e) 33 No.SFOD-OMT0011CN-A (1-2) a) View(V) 4.1 (1-1-2) View (V) b) Step No Edit OK c) d) OK (No. SFOD-OMT0009) 4.5 (0,0) (No.