The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD, BLOCK TIE ROD, VALVE, SS5V1 MANIFOLD SV1000, 11, SS5V1 OTHER SIZE RATING, .06090 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), CLAMP ASSY, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .05720 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), BLANK STATION PLATE, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .03344 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), INTERFACE REG, W/ METRIC GAUGE, VALVE, SS5V1 MANIFOLD SV1000, 22, SS5V1 NO SIZE RATING, .14698

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), MFLD, BLOCK CASSETTE, VALVE, SS5V1 MANIFOLD SV1000, 11, SS5V1 OTHER SIZE RATING, .06600 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY INT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .22440 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), 2-STAION SV1000 TIE ROD, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .01034 lb

, SS5V1 BUILT IN FITTING 1/4), 1.36684 lb, Model1, 5, 3(P,EA,EB)4, 2(A,B)bCvbCvSS5V1-10C8C60.980.260.241.10.350.28

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY EXT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .26400 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY INT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .39160 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), INTERFACE REG, W/ PSI GAUGE, VALVE, SS5V1 MANIFOLD SV1000, 22, SS5V1 NO SIZE RATING, .09680 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY INT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .22000 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), D-SIDE ENDPLATE, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .38280 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY INT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .16500 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), INTERFACE REG, W/ METRIC GAUGE, VALVE, SS5V1 MANIFOLD SV1000, 22, SS5V1 NO SIZE RATING, .10120

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), D-SIDE ENDPLATE, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .33048 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), END PLATE, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .24948 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), TIE ROD, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .04114 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH BLOCK ASSY INT, VALVE, SS5V1 MANIFOLD SV1000, 21, SS5V1 NO SIZE RATING, .24200 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH END BLOCK ASSY, VALVE, SS5V1 MANIFOLD SV1000, W1, SS5V1 BUILT IN FITTING (>1/4), .47300