Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 06 (6 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 10 (10 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Stations: 8 Stations, Port Size: 04 (1/2), Thread: N (NPT), SI Unit: SQA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit COM: N (-COM)
Size: 4 (40), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: B (24 VAC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 4 (40), Valve Type: 1 (Normally Closed), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor), Oil-free Option: None, Bracket: B (Bracket)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Size: 4 (40), Valve Type: 2 (Normally Open), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 4 (40), Valve Type: 2 (Normally Open), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: B (24 VAC), Electrical Entry: CS (Conduit, w/Surge Voltage Suppressor)
JIS Symbol 15-9-19 2 Series AS How to Order 2 2 1 U02 06 K AS 1F Nil Option Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard None Hexagonal lock nut Electroless nickel plated K N If more than one option is required, write option part numbers in the order of K, N. Applicable tubing O.D.
Valve size 1: VN1-A16 (with thread) Valve sizes 2 to 4: VN-16 Nil F N T A B C NBR seals FKM seals EPR seals Nil B Note) None With bracket Refer to Table (1) for availability. 2 0 1 A VNA Air operated 15A 2 to 4 External pilot solenoid 2 VNA 1 1 A 15A 1 T CE-compliant Nil Q CE-compliant Note) CE-compliant: For D or DZ only Manual override Rated voltage Valve size Valve type Port size 3 Note
Rp 3/4 socket 1B union 1 1/2B union Rc 3/8 (Rc 3/8) 24 Rc 1/2 (Rc 3/8) 55 36 18 Munsell N-8 (White), Munsell 2.5PB5/8.5 (Blue) 37 22 15 7.5 Thermometer for outlet air temp. (1 pc.) Drain valve (1 pc.) Union (2 pcs.)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: NZ (N + Z)
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: CG (C + G), Semi-Standard 1: 1N (1 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)