SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-42-10-01"

40 80 50 50 20 20 Load mass m (kg) Load mass m (kg) Load mass m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

CE2 ML2B ML2B ML2B/W1 ML2B/W2 ML2B/W3 ML2B/W4 50 10 10 20 4 5 3 4 5 10 Load weight (kg) Load weight (kg) Load weight (kg) Load weight (kg) 10 3 5 4 3 2 2 5 2 1 1 1 0.5 0.4 0.3 0.5 0.4 0.3 ML2B40 ML2B40 ML2B32 ML2B32 1 ML2B40 ML2B40 ML2B32 ML2B32 ML2B40 ML2B40 ML2B32 ML2B32 ML2B25 ML2B25 ML2B40 ML2B40 ML2B32 ML2B32 ML2B25 ML2B25 0.2 0.2 0.5 ML2B25 ML2B25 ML2B25 ML2B25 0.1 0.1 100 200 300 400

14 15 18 20 5 5 8 19 21 27 30 19 21 27 30 34.5 37 42 47.5 34.5 35.5 42 47.5 CQ-C012 CQ-C016 CQ-C020 CQ-C025 25 28 35 40 25 28 35 40 100 100 4 4 5 5 4 4 5 5 12 16 20 25 12 16 20 25 45.5 49 54 57.5 39.5 40.5 52 57.5 CQ2 80 90 10 5 5 8 CQ-C012 CQ-C016 CQ-C020 CQ-C025 100 100 CQS 80 90 10 The double clevis pin and retaining ring are not included.

50 292.5 (294.5) 308 (310) 332 (334) 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 Note) ( ): CE-compliant product (-Q) Flange Type/Port size: 65F, 80F Pg9 Applicable cable O.D. 6 to 8 Light/surge voltage suppressor (For DZ) Manual override (Non-locking push type) Pilot port 12(P1), 10(P2) 1/4 30 D 12 P1 P2 B (Air operated) H (External pilot solenoid

It is necessary to set it on the PLC side according to the kind of PLC. 6.2 The recommended value of the parameter [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Lead symbol H A B H A B T Series Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para.

The drain pipe must have a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto drain). 180C Inlet air temperature Correction factor Air flow (l/min (ANR)) Cooling water (l/min) Model 70C 41.5 43 45.5 37 43 49.5 37 43 45.5 37 42 43.5 50C 38.5 40 42 36 40 45.5 36 40 42.5 36 40 41 100C 37.5 47 51 38 44.5 48 35.5 36 36.5 33.5 36 38 33.5 36 36.5 33.5 35 36

series 02 03 04 06 10 12 14 20 Caution L (2) Note 1) AS800 is available as special.

If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute. K When an object is placed in a fluid stream, a vortex will be created in the fluid on the downstream side. This vortex is called a Karman vortex.

2-5.5 through Angle adjustment bolt 6 Adjustment: Max.10.2 2-M5 x 0.8 1.5 7 +0.030 0 3-4H9 long groove depth 3 ( A , B , C ) 4-M5 x 0.8 depth 10 B port A port 0.5 6g6 0.004 0.012 14h9 0 0.043 42 0 0.062 48h9 41 7 Rotary Table High Precision Type Series MSUA These drawings indicate the condition when the B port is pressurized.