Normal Bottom Peak BATTERY 1.5V x 2 LR6 G kV MADE IN JAPAN IZD IZE POWER LIGHT 110 Do not apply a strong impact on the sensing part.
Do not use the product outdoors. 2. Do not place heavy objects on top of this product, or step on it. The external panel can be deformed and danger can result. Caution 1. Install on a rigid floor which can withstand this products weight. 2. When you remove casters to install the product, lift the product at least 10 mm by using adjuster-foot etc.
Do not use the back pressure regulator as shutoff valve or safety valve. 2.
Connect End Plate and tighten removed screws by specified tightening torque. (0.6 Nm) SW1 SW2 SW3 SW4 SW5 SW6 Node ID Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Socket connector pin layout 5 Green / Yellow: Not connected Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Yellow flashing Bus IN side: Link, Activity(10 Mbps) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
ON ON Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 1 2 3 4 5 6 7 8 Settings2 1 2 3 4 5 6 7 8 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
ON BUS OUT side: Link, No Activity 1 2 3 4 5 6 7 8 (Green) Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. OFF. Parameter Setting Hardware Configuration I/O Map Diagnostic Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Refer to the valve catalogue for valve manifold dimensions. 1 ASInterface line (+) AS-i + 2 4 (0 V) RESERVE 2 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Pin Allocation 4 Over current protection Yes 1 UT1 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. SF and BF Indicators Yes Over current detection 2 DI (Input signal "n+4") FS LED 3 1 BF SF Description 3 0V (US1) Fieldbus Do not operate the product outside of the specifications.
Input (Only connector "0") 2 1 2 Input No.1 1 3 Power supply (0 V) 1: Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly inputted the input connector "0". 2: N.C.: Not connected 5 3 4 Input 4 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. EX9-PE1 power input connector No.1 M12 5-pin plug B-code Element No.
Do the same for release (push and rotate for 90 degrees). Tighten the piping using the correct torque shown below.
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
Do not scratch or gouge the escapement by dropping or bumping it when mounting. Even a slight deformation can cause inaccuracy or malfunction. 2. Please observe the specified torque limits when tightening screws to mount the attachment.
M5 x 0.8 (Finger opening port) D3 O 20S 13 3 23 7 M5 x 0.8 (Finger closing port) 4 2 MHY2-10D2 Opening/Closing direction through-hole type 4-3.4 (Hole for mounting attachment) 6 0.005 0.025 3 6 12 (Limted area for mounting attachment) Do not extend the attachment from limited area for mounting to avoid interference with the attachment or main body. 12-10-11 11 Series MHY2 Dimensions MHY2
If the tubing is inserted without holding the elbow, excessive force can be applied to the valve and fitting assembly, causing air leakage or damage, etc. 1) Nylon tubing within 0.1 mm 2) Soft nylon tubing within 0.1 mm 3) Polyurethane tubing within +0.15 mm, within 0.2 mm Do not use tubes which do not meet these outside diameter tolerances.
;(E a Slip exceeding retaining force may damage brake shoe, which could lead to reduced relaining force, resulting in its shorter lile a Cylinder loading should be within 35'/" of holding force when the brake is used for droo oroteclion, a Do not apply any impact when you load the cylinder in the locked position.