Element Material: S (Stainless Steel 316), Element Size: 100 (ø65 x â„“250), Nominal Filtration Accuracy: 100 μm, Element Seal Material: V (FKM)
Element Material: B (Bronze), Element Size: 100 (ø65 x â„“250), Nominal Filtration Accuracy: 100 μm, Element Seal Material: N (NBR)
Element Material: S (Stainless Steel 316), Element Size: 100 (ø65 x â„“250), Nominal Filtration Accuracy: 100 μm, Element Seal Material: T (Fluororesin)
Element Material: B (Bronze), Element Size: 100 (ø65 x â„“250), Nominal Filtration Accuracy: 100 μm, Element Seal Material: T (Fluororesin)
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
Please keep this manual handy for future reference. 010 1 [m] SAPA Socket side: Angled Plug side: Angled Communication cable 030 3 [m] 050 5 [m] 100 10 [m] LED PWR COM ERR L LED To obtain the operation manual about this product and control unit, please refer to the SMC website (URL http://www.smcworld.com) or contact SMC directly.
39 87 114 95 70 76.5 36 9 P.C.D 92.1 8x8.4 XMC-80 90 250 117 45.5 114 110 83 105 44 9 9 XM-OMP0002-A 4-3.
How to order 002 FGH 100 03 T Element seal aterial PTFE Nominal filtration accuracy Nominal filtration Applicable Applicable Symbol accuracy Element model Element length 002 2m Filtration Element Applicable 004 4m HEPO FGH100 Symbol efficiency length Element 300 006 6m 99% 100 L117 EJ701S 013 13m 200 L246 EJ801S,ED801S X20 0.2m Filtration FGH200 300 L496 EJ901S,ED901S efficiency Membrane
Table 6-9 Rating Soldering terminal Rated voltage Resistance load 250 VAC 5A (3) Other performance Table 6-10 Other specifications Item Specifications Insulation resistance 100 M or more (Measured by 500 VDC, insulation resistance tester. ) Contact resistance 30m or less Between terminals with the same pole AC1000V 50/60Hz 1min Between charged metal part and ground AC1500V 50/60Hz 1min Withstand
Use an air compressor of 100 l/min or greater air delivery. Since the auto drain is designed in such a way that the valve remains open unless the air pressure rises to 0.15MPa or higher, air will blow out from the drain discharge port when the air compressor starts up until the pressure increases.
Maximum Load Weight (g) Weight (g) Cylinder stroke (mm) 5 Maximum load weight Model Model 10 15 20 25 30 MXU6 MXU10 MXU16 MXU6 MXU10 MXU16 100 66 72 81 88 97 103 200 115 124 138 147 166 174 400 216 215 251 250 285 300 8-3-3 4 Series MXU Allowable Moment Precautions Allowable moment (Nm) Correction value of moment center position distance (mm) Model Stroke Be sure to read before handling.
Auto switches are mountable/removable even when the plate is retracted.Guide rod type compact cylinder , Bore sizes *: 12, 16, 20, 25, 32, 40, 50, 63, 80, and 100, Standard strokes *: 5 to 100 , 4 times the lateral load resistance of the CQ2K , Non-rotating accuracy 0.2 or less COMPACT CYLINDER W/GUIDE. Compact Guide Rod Cylinder, CQM. 250 lb.
width: 50 msecOutput voltage: 1 to 5 V; Load impedance: 100 k or moreOutput current: 4 to 20 mA; Load impedance: 250 or less1 sec. or lessHysteresis mode: Variable (can be set from 0); Window comparator mode: (can be set from 0 to 3% F.S.)24 VDC (ripple ?
width: 50 msecOutput voltage: 1 to 5 V; Load impedance: 100 k or moreOutput current: 4 to 20 mA; Load impedance: 250 or less1 sec. or lessHysteresis mode: Variable (can be set from 0); Window comparator mode: (can be set from 0 to 3% F.S.)24 VDC (ripple ?
width: 50 msecOutput voltage: 1 to 5 V; Load impedance: 100 k or moreOutput current: 4 to 20 mA; Load impedance: 250 or less1 sec. or lessHysteresis mode: Variable (can be set from 0); Window comparator mode: (can be set from 0 to 3% F.S.)24 VDC (ripple ?
width: 50 msecOutput voltage: 1 to 5 V; Load impedance: 100 k or moreOutput current: 4 to 20 mA; Load impedance: 250 or less1 sec. or lessHysteresis mode: Variable (can be set from 0); Window comparator mode: (can be set from 0 to 3% F.S.)24 VDC (ripple ?
width: 50 msecOutput voltage: 1 to 5 V; Load impedance: 100 k or moreOutput current: 4 to 20 mA; Load impedance: 250 or less1 sec. or lessHysteresis mode: Variable (can be set from 0); Window comparator mode: (can be set from 0 to 3% F.S.)24 VDC (ripple ?