cord O.D. 4 to 6.5 78.5 Max .10 71.5 71 Light (DZtype only) 67.5 59 32 17 2 2-4.5 (mounting holes) P 19 35 P Pg.7 2-Rc(PT) 1/8 (ports P) A A A 11 20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port R) 47.5 11 R R P = 19 19 L: Dimension table n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7
@-@n-m a 16 points preset type Note 1) E in parl number is lhe same modelno. for the standard products.
(P), 3 (R) port 4-Rc1/8 Indicator light 7 2-4.5 (Mounting hole) 57 5.3 5.3 50.5 52 0.6 4 4 4 4 4 P 1 R 3 R 3 P 1 30 17 6.5 15 2 2 2 2 2 8 0.5 0.5 P=11 10 M5: M5 thread 2n-M5 4(A), 2(B) port 35 4 L2 38 L1 42 M plug connector (M) Stations 1 2 3 4 5 n D side U side Direct manual override (Non-locking) 24 15 43 L plug connector (L) n: Stations Dimensions n L 11 12 13 14 15 16 17 18 19 20 28 20
PFM5-(N)01/(N)02/F01-1/2 -25No.PF-OMJ0016-J PFM5-(N)01L/(N)02L/F01L-1/2 -26No.PF-OMJ0016-J PFM5S-(N)01/(N)02/F01-1/2 -27No.PF-OMJ0016-J PFM5S-(N)01L/(N)02L/F01L-1/2 -28No.PF-OMJ0016-J PFM5-F02-1/2 -29No.PF-OMJ0016-J PFM5-F02L-1/2 -30No.PF-OMJ0016-J PFM5S-F02-1/2 -31No.PF-OMJ0016-J PFM5S-F02L-1/2 -32No.PF-OMJ0016-J PFM5-C/N-1/2 -33No.PF-OMJ0016-J PFM5-C/NL-1/2 -34No.PF-OMJ0016-J PFM5S-C/N
D-X 100 Lateral load F (N) 2080 10 Data 63 50 Operating pressure 0.5 MPa Operating pressure 0.4 MPa 40 32 25 Graph (1) 1000 20 1 10 100 300 Stroke + Eccentric distance (mm) Cushion Needle Adjustment 100 100 Load weight kg Caution 80 63 50 1.
TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 12-CY3B6 12-CY3B10 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 12-CY3B50 12-CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2
Work piece weight (kg) 10 10 5 5 1 1kg 1 0.25kg 0.1 10 20 40 0.1 5 10 20 30 Transfer speed (m/min) Transfer speed (m/min) 32.5m/min 12m/min Procedure3 Confirmation of allowable lateral load MIW12 MIS12 1. Calculation of applied lateral load F F = N m g (N) = 0.2 x 10 x 0.1 x 9.8 = 2.1 (N) 1.
End plate assembly 1 pc. 28 x 25 x 1.5 35 x 31 x 2 2500 3000 A B 756 Manifold Regulator ARM2500/3000 Series Dimensions Pressure gauge (Option) Pressure gauge (Option) (With pressure gauge) ARJ AR425 to 935 Panel mounting hole ARX ARM2500: 4 x 6 ARM3000: 4 x 7 AMR ARM ARM ARP IN (Common IN) IR-A ARM2500: 2 x 3/8 ARM3000: 2 x 1/2 IR IRV ARM2500: n x 1/4 ARM3000: n x 3/8 Gauge port n x 1/8 VEX
1/16"), 150 (1-1/2"), 200 (2"), 250 (2-1/2") N-through hole H-thread C-depth 4 places Z Q Q P-port 2 places J E M2 bolt circle W M1 D-rod dia.
type Max. number of stations Applicable solenoid valve B mount 20 stations (1) VO317(3) Port location (Direction)/Port size A Exhaust port Symbol Type R P Base (Side) Base (Side) Base (Side) ( ) 1 4 3 8 1 Common (2) ( ) 1 4 3 8 1 4 Base (Side) Base (Side) Base (Side) VV317-02-053-02 3 Individual 1 4 1 4 1 4 Individual exhaust Note 1) For more than 3 stations, supply air both sides of P port
HRX-OM-W032 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using the Product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety instructions for use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures.
M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS
Sizes 10, 15 Sizes 20, 30, 40 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Flat Key Port B Port B 0 0 0 0 0 19 1 1 0 to to to 19 0 Port A 0 0 8 8 Port A to e 17 at g 0 n fl ra e 17 of ng n o e at ra ti g ta n fl ra ro on of e n Angle adjustment 5 Angle adjustment 5 ov io ti at e o ta gr ot ng R ey ro K ra ve n oo io at
-N Dimensions: AS2000/3000 Dimensions: AS4000 AS-FG AS-FP 2 x 1/4 to 1/2 AS-FM 68.5 (Max.76.5) AS-D AS-T 2 x Port size ASP ASN AQ ASV 2 x D AK Dimensions Max.
/disconnection status 1 N 3.4.14 0x0058(88) 1...16 R Valve protection status 1 N 3.4.15 0x0059(89) 1...16 R Supply valve type status 1 N 3.4.16 0x005A(90) 1...16 R Pressure/Hysteresis parameter failure status 1 N 3.4.17 0x005B(91) 0 R Receive error count 4 N 3.4.18 0x0091(145) 0 W Zero clear 1 N 3.4.19 0x0092(146) 0 W Valve protection release 1 N 3.4.20 Note "Y" means included in DataStorage
2 pcs. 1 pc. n pcs.
None N None 3 3 5 5 J 3 E 0.5 10 10 K 5 Straight G 1 15 15 M 10 H 2 Straight N None S 3 J 3 T 5 Angle K 5 To use AC adapter, with transistor Input/Output specify "N", and select AC adapter with the option number.
(P.50) (1) M 41 No.JXC-OMU0004-A 2 * M (3) () M () ON M 42 No.JXC-OMU0004-A 8.4 1 1 1 1 1 1 1 10.
JIS cass 2 Standad @w $enhs C[028 Distance From Auto Switch Side Face e1 ili-l ffi 7T\ '1 (f|/ l r : 1 1 Distance From Auto Switch Top Face : t l . : : : : : : : . . 9 ^ ^ t2 ,r,rl fl^l rtu .9 o 1 0 : : : : : : : : : , : : azw, 7 Sg|'ies C[028P flislr ilrulrtric rierd Rt$i$h Through Hole Mount:CDQ2BPtrnDM-n I Note Eemale lhredd and rod drmensrons are the same as for clevis and head llange