SMC Corporation of America
Elite Part Number Search
Search Results "NALT-9-IS-2"

To release, an external 2 port valve (vacuum valve) must be provided. Application: The supply pressure is controlled by the external 2 port valve (vacuum valve) and releasing is also effected by the extermal 2 port valve.

Side scraper 33 MYB25-15BA5900B MYB32-15BA5901B MYB40-15BA5902B Polyamide 2 37 !7 !8 !9 @0 #4 Cushion boss gasket MYB25-16GA5900 MYB32-16GA5901 MYB40-16GA5902 NBR 2 Scraper NBR 2 Piston seal NBR 2 MY1B25-PS MY1B32-PS MY1B40-PS MY1B25-PS MY1B32-PS MY1B40-PS Cushion seal NBR 2 Tube gasket NBR 2 O-ring NBR 2 Seal kit includes !7, !8, !9, @0 and #4.

Side scraper 33 MYB25-15BA5900B MYB32-15BA5901B MYB40-15BA5902B Polyamide 2 37 !7 !8 !9 @0 #4 Cushion boss gasket MYB25-16GA5900 MYB32-16GA5901 MYB40-16GA5902 NBR 2 Scraper NBR 2 Piston seal NBR 2 MY1B25-PS MY1B32-PS MY1B40-PS MY1B25-PS MY1B32-PS MY1B40-PS Cushion seal NBR 2 Tube gasket NBR 2 O-ring NBR 2 Seal kit includes !7, !8, !9, @0 and #4.

Model VBAT05A-SV-Q VBAT10A-SV-Q VBAT20A-RV-Q VBAT38A-RV-Q Accessory kit Safety valve Drain valve VBAT5A-Y-2 VBAT-S (Set pressure: 2 MPa) VBAT-V1 VBAT10A-Y-2 VBAT20A-Y-2 VBAT-R (Set pressure: 1 MPa) The Accessory Kit is a Set of Nos. q to t. VBAT20A-Y-2 VBAT10A-Y-2 Model Description No.

9 @0 21 @2 Rod seal NBR Set of left nos. !6, !7, !8, !9, @0, @2 Scraper NBR Piston seal NBR 21 is a non-replaceable part, so it is not included in the seal kit. Tube gasket NBR Seal kit consists of items !6 to @0 and @2 and can be ordered by using the seal kit number for each bore size. Cushion seal Back-up ring Resin Cushion valve seal A NBR 207

NPT1/4 (applicable to AW30 to 40) Note 2) Drain guide is G1/4 (applicable to AW30 to 40).

ON Switch output 1 & 2 OFF Time ( ) When the auto shift function is turned "off", the shift value will be zero. Switch output response time when auto shift is input.

MPa SET kPa Displays alternately OUT1 OUT2 CH 1 2 3 4 On Off CH3 PRESSURE SET SET MPa kPa Displays alternately OUT1 OUT2 CH 1 2 3 4 On Off CH4 PRESSURE SET SET Setting is complete.

Note 2) In the case of a sintered metal element or paper element. 262 Industrial Filter P.466 Series FGG 2 Replacement Procedure is Replacement Parts and Seal List Actuators Modular F.R.L.

Note 2) In the case of a sintered metal element or paper element. 262 Industrial Filter P.466 Series FGG 2 Replacement Procedure is Replacement Parts and Seal List Actuators Modular F.R.L.

Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Load impedance is 3 k. Leakage current from auto switch is 1 mA.

Supply valve (2 port valve) + Suction filter Ex. 1 Ex. 4 Supply valve (2 port valve) + Release valve (2 port valve) + Variable throttle + Silencer + Suction filter + Pressure gauge 2 port valve 2 port valve Ejector Silencer Exhaust port 2 port valve Suction filter Pressure gauge Suction filter Variable throttle 2 port valve is used to generate and stop the vacuum.

Therefore, the flow passage from the valve e to port 2 (A) is still closed. Furthermore, the piston r is pushed down due to the pilot air, and the flow passage from the needle t to port 2 (A) opens.

ON Switch output 1 & 2 OFF Time ( ) When the auto shift function is turned "off", the shift value will be zero. Switch output response time when auto shift is input.

Note 2) 4 to 20mA is not possible with the 2 wire type. Power supply voltage (24V DC or 12 to 15V DC) is required. Note 3) Either analog output or switch output must be selected. Furthermore, when switch output is selected, either NPN output or PNP output must also be selected. Please note that the preset input type is not equipped with an output signal function.

Note 2) Auto shift function is not available when analog output option is selected. Also, analog output option is not available when auto shift function is selected.

Air Slide Table Series MXP 6 Replacement Procedure is P.326 Construction MXP6 !4 !3 !2 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MXP. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) A set of two of !2, !3 and !4 each !2 !3 !

Total Land Area: 55,647m 2 Floor Space: 23,022m 2 Total Land Area: 124,227m 2 Floor Space: 17,204m 2 Tohno Factory (Iwate Prf.) Total Land Area: 60,638m 2 Floor Space: 10,622m 2 Tsukuba Factory (Ibaragi Prf.)

Since Q0 = 15/45 = 0.33 [ /min], according to the Graph (2), if reading P when Q0 is 0.33, it will be 0.031 [MPa]. Example 2) Obtain the flow rate of saturated aqueous vapor when P1 = 0.8 [MPa], P = 0.008 [MPa] with a solenoid valve with an Av =1.5 x 106 [m2]. According to the Graph (2), if reading Q0 when P1 is 0.8 and P is 0.008, it is 0.7 [kg/h].

Host STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 () () Thermo-con ACK CR Host SOH UT STX 31H Setting data ETX Check sum CR 101 100 10-1 10-2 () () Thermo-con ACK UT CR 4-2 Reading setting temperature As 0.1 deg.C is the minimum unit, the number in the hundredths place (10-2) is always 0 (=30H).