Minimum bending radius: Power supply cable30 mm (Note: Shown above is wiring with the fixed minimum allowable bending radius and at a temperature of 20C. If used under this temperature, the connector can receive excessive stress even though the minimum bending radius is allowable.)
Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance.
Pressure spindle Stainless steel 303 POM, NBR, Stainless steel 303, Stainless steel 304 KN KN Sensing head (KNP) One-touch fittings Applicable tubing O.D. 4 Polyurethane Polyurethane tube (4, 1 m) Fluid Air KNP-2 Maximum operating pressure (at 20C) 0.8 MPa 5 to 60C (No freezing) Ambient and fluid temperature Pipe Stainless steel 304 POM, NBR, Stainless steel 304 One-touch fittings Polyurethane
Please contact SMC for further details. 2 Based on the JIS B 8419:2010 dynamic performance test (Coil temperature: 20C, pressure: 0.5 MPa, at the rated voltage) 3 Impact resistance: No malfunction occurred when it was tested in the axial direction and at a right angle to both the main valve and the armature in both an energized and de-energized state, once for each condition.
Port size Symbol Port size 10 R1 Specifications FND100V-10-M149X0 Model FND100N-10-M149X0 R1 Port size Bowl & Cover Stainless steel 304 O-ring Material NBR FKM Element Stainless steel 304 149 m Element nominal filtration rating Weight 7.5 kg Note) Produced upon receipt of order. 2 Series FN1/FN4 Flow Characteristics (Initial Value) P Test fluid: Potable water P Liquid temperature: 17 to 20C
4 15 1/4: 30 3/8: 40 Oil capacity [cm3] 7 25 55 135 Recommended lubricant Class 1 turbine oil (ISO VG32) Bowl material Polycarbonate Bowl guard Semi-standard (Steel) Standard (Polycarbonate) Weight [kg] 0.07 0.10 0.20 0.38 0.43 0.94 1.09 *1 The flow rate is 5 drops or greater/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C
Heat generation amount Q : Unknown : 1.0C (1.0 K) : 20C (293.15 K) : 21C (294.15 K) : 7 L/min :Water : Density : 1 x 103 kg/m3 Circulating fluid temperature difference T (= T2 T1) Circulating fluid outlet temperature T1 Circulating fluid inlet temperature T2 Circulating fluid flow rate L Circulating fluid : Specific heat C: 4.2 x 103 J/(kgK) T1: Outlet temperature Q = T x L x x C 60 x 1000
(Inlet air pressure: 0.7 MPa, Inlet air temperature: 20C) Accessory (Option)/Replacement Parts Applicable model ID20 ID30 ID40 ID60 6604113 6604113 660651 660651 ID-200S ID-300S ID-400S ID-600S ID-200Z ID-300Z ID-400Z ID-600Z ID-DPM8 Bracket Adsorbent set Note) Adsorbent set (for low dew point) Note) Indicator set Note) Adsorbent and adsorption tube filter for one air dryer (two adsorption
.: 1/2 inch [Thread symbol: N], 12 mm [Thread symbol: Nil]) Drain tube holder, Operation manual Compliant standards UL, CSA Refrigerated air dryer Auto drain 1 The operating range does not guarantee use with normal air flow capacity. 2 Air flow capacity under the standard condition (ANR) [atmospheric pressure 68F (20C), relative humidity 65%] 3 When the operating conditions are different
S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev) 25APower consumption [W] Note 7) Horizontal 45 65 210 Vertical 145 175 230 LEC Standby power consumption when operating [W] Note 8) Horizontal 2 2 2 Vertical 8 8 18 LEC S Max. instantaneous power consumption [W] Note 9) 445 725 1275 Type Note 10) Non-magnetizing lock Holding force [N] 131 255 197 385 330 660 Power consumption at 20C
Resolution: 131072 p/rev) Motor type S6, S7: Absolute 18-bit encoder (Resolution: 262144 p/rev) Power consumption [W] Note 7) Horizontal 65 80 Vertical 165 235 Standby power consumption when operating [W] Note 8) Horizontal 2 2 Vertical 10 12 Max. instantaneous power consumption [W] Note 9) 445 725 Type Note 10) Non-magnetizing lock Holding force [N] 101 203 330 660 Power consumption [W] at 20C
ON: 5 or less, OFF: 4 or less Response time (DC) ms Note 1) 20 Max. operating frequency (Hz) Manual override Non-locking push type, push-turn locking slotted type Not required Lubrication Unrestricted Mounting position 150/30 Impact / vibration resistance (m/s2) Note 2) Dust tight Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981 (Standard type :Coil temperature 20C, at
(Coil temperature: 20C, pressure: 0.5 MPa, at rated voltage, with light and surge suppressor, value at operation excluding restart period) The period immediately after a restart may be delayed for about 1 msec depending on operating conditions. Note 2) Use dry air to prevent condensation when operating at low temperatures.
size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled flow Free flow Critical pressure ratio 20 100 180 230 260 390 460 660 790 920 1580 1710 Flow rate L/min (ANR) Sonic conductance dm3/(sbar) 0.06 0.28 0.5 0.64 0.72 1.1 1.8 2.2 4.4 4.8 1.3 2.6 0.2 0.2 0.25 0.3 0.25 0.25 Controlled flow 0.4 0.4 0.2 0.3 0.2 0.3 Free flow Note 1) Flow rate values are measured at 0.5 MPa and 20C
" 1 2 Flow Direction Symbols on Body Flow rate (L/min (ANR)) 180 230 460 260 390 660 790 920 1580 1710 Controlled flow Free flow Meter-out type Meter-in type Sonic conductance dm3/(sbar) Indication symbol 0.5 0.64 1.3 0.72 4.4 4.8 1.1 1.8 2.2 2.6 Controlled flow 0.25 0.3 0.25 0.25 Critical pressure ratio Free flow 0.2 0.3 0.2 0.3 Symbol Note) Flow rate values are measured at 0.5 MPa and 20C
Capacity between levels 350) Turbine oil Class 1(With no additives), ISO VG32 5 to 60C (No freezing) Polycarbonate Bowl capacity (cm 3) Recommended lubricant Ambient and fluid temperature Bowl material 1.56 1.78 Weight (kg) Bowl guard Accessory (Standard) Note) Conditions: Inlet pressure = 0.5 MPa, Number of drop = 5 drops/min, Turbine oil Class 1 (with no additives) ISO VG32, Temperature = 20C
12.3 810 12.3 32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C
AS3001F AS2051F AS4001F AS2001F AS1001F Model Metric size 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 5/32" 3/16", 1/4" 3/16" 1/4", 5/16" 1/4" 5/16" 3/8" 3/8" 1/2" Inch size Controlled flow (Free flow) 100 130 230 290 460 420 660 920 1050 1390 Air flow /min (ANR) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Effective area (mm 2) Note) Flow rate values are measured at 0.5 MPa and 20C
AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 1.5 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 2 6 8 1/4" 5/16" 460 7 6 10 8 10, 12 6 JIS symbol Inch size Tube O.D. 5/16" 5/32" 1/4" 1/4" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 660 10 290 4.5 390 6 920 14 920 14 1390 21 20 0.3 130 2 230 3.5 Controlled flow (Free flow) Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C
operating pressure 5 to 60C (No freezing) 10 turns 10 turns 8 turns Ambient and fluid temperature Number of needle rotation Hexagonal lock nut With seal, Hexagonal lock nut, Nickel plated Option 181 106 64 29 10 6 3 Weight (g) 20 0.3 1700 26 920 14 460 7 230 3.5 105 1.6 Flow rate /min (ANR) Controlled flow (Free flow) Effective area (mm2) Note 1) Flow rate values are measured at 0.5 MPa and 20C