Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.
Standard Strokes Bore size [mm] Standard stroke [mm] Note 1) Long stroke [mm] Note 2) 40 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500 800 Refer to pages 18 to 23 for cylinders with auto switches. 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250 300, 350, 400, 450, 500, 600 1200 Minimum stroke for auto switch mounting Auto switch proper mounting position (detection at
Models Standard strokes (mm) 32 40 50 63 MGP 25, 50, 75, 100, 125, 150, 175 200, 250, 300, 350, 400 M L Intermediate strokes (in 5mm increments) are produced by installing spacers of 5, 10, 15 and 20mm widths. When a special intermediate stroke body is needed, contact SMC.
Size M Size N Unit number Pilot unit part number Part number Orifice size Stroke 10 to 85mm (Accessory Nil) Actuator Capacity 90cm3 P368010-20 125 150 P565010-18 P36801080 0.7 35 to 100mm (Accessory E) 180cm3 P368010-21 110 195 P565010-19 P36801081 1 50 to 140mm (Accessory F) P368010-22 110 275 Fork lever joints (IP8100 type) Two types of the fork lever joints are available dependent upon
110 44 to 600 104 145 LJ1H101NB 4 46 to 600 LJ1H202SC 124 112 16 58 to 500 LJ1S303SC 146 132 120 92 98 to 300 to 300 to 300 LJ1H202PA 8 50 to 500 124 112 106 LJ1H202NA 12 54 to 500 LJ1H303SE 126 114 22 64 to 500 to 500 to 500 LJ1H202PC 10 52 to 1000 to 740 to 930 to 600 to 500 145 124 112 106 LJ1H202NC 14 56 to 740 to 930 to 600 to 500 to 1000 LJ1H303PD to 1000 to 1000 to 700 to 500 18
Note 2) Measurement values based on a charged plate (dimensions: 150 x 150 mm, electrostatic capacity: 20pF) defined by ANSI standard (ANSI/ESD STM3.1-2006). Distance between charged plate and ionizer: 100 mm, Air purge: 0.3 MPa (energy saving nozzle) / 0.1 MPa (high flow rate nozzle). Note 3) Charge elimination is not possible without air purge.
H4 Initial power / 100 VAC 200/40 200/50 400/100 600/150 Power Symbol 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
Peltier-type Chiller Thermo-con/ Compact Type Air-cooled Compact 130 mm x 210 mm x 150 mm Height Width Depth Low-noise design (at low load): 37 dB 130 mm 150 mm Display/Operation panel 210 mm Circulating fluid level gauge Dustproof filter Replaceable Cooling capacity: 220 W Superior temperature control Temperature stability: 0.1C Now only takes about 41 seconds to lower the temperature by
Specification Specification Applicable model AMH 150~AMH850 Applicable model AMH450 ~ AMH850 How to Order *Refer to" How to Order" for standard type. How to Order *Refer to" How to Order" for standard type.
200 50 100 150 200 Arm length [mm] Arm length [mm] The maximum clamping force when the arm length is 100 mm and the operating pressure is 44 psi [0.3 MPa]: With an arm length of 100 mm and an operating pressure of 44 psi [0.3 MPa], according to the graph, the maximum clamping force is 45 lbf [200 N].
Ambient and fluid temperature (C) Response time (ms) (1) (at the pressure of 0.5 MPa) 0 (No freezing) to 60 OFF AC 30 or less ON AC 30 or less DC 30 or less DC 40 or less Max. operating frequency (Hz) 3 Lubrication (2) Required (Equivalent to turbine oil Class1 ISO VG32) Manual override Yes (Non-locking) Mounting orientation Unrestricted 150/50 Impact/Vibration resistance (m/s2) (3) Note
Caution Be sure to read before handling.Refer to pages 14-21-3 to 4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, pages 14-14-6 to 8 for Precautions on every series, and pages 14-20-62 to 64 for more detailed precautions on every series. 14-20-22 2 Micro Mist Separator Series AMD How to Order AMD150 to AMD850 AMD 250 03 J B Body size Option 1 4 150
N2CO2Ar () -4No.PF-OMJ0005CN-I () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL , (100 20 ) JIS B 8392-1 1.1.21.6.2 -5No.PF-OMJ0005CN-I * 14 FG (49 N () IN () -6No.PF-OMJ0005CN-I * () 6 33 () () 30 m DC(-)() -7No.PF-OMJ0005CN-I * () () CE 0~50 -8No.PF-OMJ0005CN-I * 3 (20 ) LED * OUT * 23% -9No.PF-OMJ0005CN-I 7 PFM (12) 2 (11) 10 0.210(5)L/min 1 25 0.525(12.5)L/min (11) 50 150
In general, 80 to 100 mesh (150 to 180 m) filters are recommended. When transferring a coagulable liquid, take measures to prevent it from coagulating in the pump. Precautions to observe when transferring slurry Basically, it is not recommended to transfer slurry because this will result in seating failure and wearing of the check valve and accumulation of particles.
No.CE*-OMI0063-C / / CE1* Series 1. 16 2. 7 2-1. 7 2-2. 78 2-2-1. 7 2-2-2. 8 2-2-3. 8 2-3. 9 3. 3-1. 10 3-2. 10 3-3. 11 3-3-1. 11 3-3-2. 11 3-3-3. 11 4. 4-1. 12 4-2. 12 4-3. 12 5. 5-1. 13 5-2. 14 5-3. 14 6. 6-1. 1516 6-2. 16 CE1B12 17 CE1B20 18 CE1B32 19 CE1B40 20 CE1B50 21 CE1B63 22 CE1 Series/ 1. 1) (ISO/IEC)(JIS) 2) *1) ISO
The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (50 kPa) when the product is set to turn ON at 150 kPa supply pressure. Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa).
Round cutting pliers Nominal: 125 or 150 Tightening torque: 1.4 0.1 Nm 10) Mount the bowl assembly. Hold the bowl assembly by hand and rotate clockwise. Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Actuators Modular F.R.L.
removal rate blowing compressor is 30mg/m3(ANR) (ANR) Accessories (Options) Applicable models AM150 AM250 AM350 AM450 AM550 AM650 AM850 Bracket assembly With cap bolt, BM51 BM52 BM53 BM54 BM55 BM56 BM57 spring washer Symbol AM Order Made P.4.6-6 How to Order AM 250 03 J B Options Body size Accessories (Options) Drain guide 1/4B female thread INOUT reversal Element service indicator None 150
assembly With cap bolt With spring washer BM51 BM52 BM53 BM54 BM55 BM56 BM57 Condition of inlet air Pressure: 0.7MPa Temperature: 25C Relative humidity: 100% How to Order AMG 250 03 J B Liquid water content (Water droplet content): 1.5g/m3 (ANR) Options Body size Compressed air flow: Rated flow of each model J Drain guide 1/4B female thread R IN-OUT reverse direction 1/8 1/4 3/8 1/2 3/4 1 150
Due to this movement, the fluid 18 Series PB1000 Piping and Operation/Built-in Solenoid Valve Type/Air Operated Type Piping Bottom view Discharge port OUT Solenoid valve lead wires Air exhaust portEXH Suction port IN Air supply port SUP Foot (optional) Manual override pin Top view The PB1013 air operated type has a plug in the air exhaust port EXH.