Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø6mm, Straight Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø4mm, Straight Type, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø1/4", Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø6mm, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø4mm, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø6mm, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø6mm, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket B, Horizontal Mounting, Option 3: w/o Operation Manual, w/o Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: w/o Lead Wire, Option 2: None, Option 3: w/o Operation Manual, w/o Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø6mm, Straight Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: None, Option 3: w/o Operation Manual, Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: One-touch Fitting ø4mm, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N, "PRESSURE SWITCH

Common setting Output mode Hysteresis mode Switch operation Normal output Set value (P) 25 Hysteresis (H) 10 Initial setting Zero cut-off setting CUt: 1.0 (displays 0 for a value below 10 L/min) Switch ON point 25 L/min or more Switch OFF point Below 15 L/min Change the zero cut-off setting The set value (P) and hysteresis (H) cannot be changed.

Common setting Output mode Hysteresis mode Switch operation Normal output Set value (P) 80 Hysteresis (H) 30 Initial setting Zero cut-off setting CUt: 1.0 (displays 0 for a value below 30 L/min) Switch ON point 80 L/min or more Switch OFF point Below 50 L/min Change the zero cut-off setting. The set value (P) and hysteresis (H) cannot be changed.

A B c D E F H K lil N P O (Ihpth) Tol{ances Tolerances NCDBBlBWlO 1 . 1 4 0.750.98 !.

Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 2 x Piping port Z U T S 4 x WX G 2 4 (35.5) 42 H For PF3W721 OUT IN AA G 4 x P K L 2 x Piping port G N DD PF3W504/520/540/511/521 Remote sensor unit Y A E J F 30 W B V 2 x Piping port Z S T U 4 x WX G H 42 (35.5) For PF3W521 IN OUT AA G 4 x P K L 2 x Piping port G N (mm) Bracket dimensions Model Port size A AA B D DD E F G H J K L N P (Rc, NPT,

The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -74- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.

The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -79- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.

Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 25 mA or less Protection Polarity protection Switch output Select from NPN or PNP open collector output Max. load current 10 mA Max. applied voltage 30.0 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided 2-screen (3-screen display available: sub display, 4 digits x 2) Main display