SMC Corporation of America
Elite Part Number Search
Search Results "CHD2HFY100C-25-D"

Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5

Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5

(Detection at Stroke End) and Its Mounting Height Auto switch D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 12 to 100 B A D-P3DW 80, 100 25 to 63 B Ht A Hs Hs Auto Switch Proper Mounting Position Applicable Cylinder Series: MGP (mm) Auto Switch Mounting Height (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV

at stroke end) and Its Mounting Height 20/25 D-A9V D-M9V D-F9WV D-A9 D-M9 D-F9W D-F9BAL Approx.

Max. 24 stations Side C10 C4, C6, C8 D-sub Connector (25 Pins) Cable Assembly AXT100-DS25015 030 050 Wire color by terminal no. of D-sub connector cable assembly The D-sub connector cable assembly can be ordered individually or included in a specific manifold model no. Refer to How to Order Manifold. Terminal no.

(Same surface) 60 65 D-Y59/Y69 D-Y7P/Y7PV 2 pcs. (Different surfaces) 20 20 1 pc. 20 20 2 pcs. (Same surface) 70 65 D-Y7W D-Y7WV 2 pcs. (Different surfaces) 25 20 1 pc. 25 20 2 pcs. (Same surface) 70 75 D-Y7BAL 2 pcs.

B L Y Model C D E K A B K L Y Model C F G G D E E ZPY20B ZPY25B ZPY06B ZPY08B 20 25 22 27 23.5 24 33.5 34 51.5 52 79.5 80 85 69.5 70 12.4 15.6 25 28 18.9 37 6 8 7 9 3.3 4.7 9.1 10.1 2.5 20 45 25 50.5 4 10.5 ZQ 25 15 32 34 29 39 57 ZPY32B 75 14 Applicable Tubing Applicable Tubing ZF P Q R Applicable tubing Q R Applicable tubing P N4 (Nylon tube, 4/2.5) N6 (Nylon tube, 6/4) U4 (Urethane tube

Number of fingers 2 2 fingers Bore size 10 16 20 25 Number of auto switches 10 mm 16 mm 20 mm 25 mm Action D S C Nil S n 2 pcs. 1 pc. n pc. For the applicable auto switch model, refer to the table below.

(mm) Bore size D-A9, D-A9V D-F9, D-F9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum stroke for auto switch mounting (2pcs.) (mm) D-A90V D-A96V D-A93V 22 Bore size D-F9V D-F9WV D-F9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 Mounting patternq, w 32 35 Mounting patterne 20 12 Auto Switch Mounting As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.

56.1 69.1 49.6 62.6 46.6 33.6 141.8[146.2] 122.2[126.6] 35 35 35 35 161.8 160 140 21 21 (For mounting) 25 21 25 21 2-3.2 (For mounting) 2-3.2 2-3.2 2-3.2 (For mounting) 25 25 (For mounting) 28 28 28 Pg7 28 Applicable cable O.D. 3.5 to 7 Refer to page 563 for dimensions with connector cable. 543 5 port solenoid valve Series 10-SYJ7000 2 position single [ ]: AC G H 01 02 Grommet (G), (H)

M5 type U10/32 type Applicable tubing O.D. d (Hexagon width across flats) Metric Size Inch Size Model d T Mass (g) H D1 D2 L1 L2 L3 L4 (1) A Model d T Mass (g) H D1 D2 L1 L2 L3 L4 (1) A Max.

The angle is 60 when any of the following are used: D-90/90A/97/93A The angle is 69 when any of the following are used: D-S99(V)/T99(V)/S9P(V) 4 R22.5 20.5 D(26.5: Connector type) [mm] Size A B C D E (g7) F (h9) G H K L M N P Q R T U W W X Y1 Y2 Z Q2 Q3 Q4 10 29 22 45.5 14 4 0.004 0.016 9 0 0.036 1 7 9 0.5 16.5 9.5 18.5 M3 x 0.5 3.5 3.5 M3 x 0.5 10.6 3 19.8 35 31 25 17 41 15 34 25 47 18

Auto Switch Mounting Height (mm) Auto switch model D-M9 D-M9W D-A9 Hs Bore size 20 25 32 40 22.5 25 28.5 32.5 717 Cylinder with End Lock CBM2 2122CBM2/ 101110112122Basic (B): CBM2B, CBM2B Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.

Hs A Auto switch mounting height (mm) Proper auto switch mounting positions (mm) D-F9 D-F9V D-F9W D-F9WV D-A9V D-F9BAL D-F9V D-F9WV D-A9 D-A9V Bore size (mm) D-F9BAL Bore size (mm) Hs Hs Hs 20 22 22.5 25 B A B A A B 20 25 36 6.5 37 7.5 33 3.5 24.5 27 24 25 32 41 8.5 9.5 38 5.5 42 27 29 26.5 32 40 8 9 43 5 44 40 32.5 30 30.5 40 50 10.5 49 7.5 50 11.5 46 36 36.5 38.5 50 63 48 13.5 49 14.5 45

140 160 45 50 55 60 65 70 75 80 85 90 55 60 65 70 75 80 85 90 95 100 110 130 150 C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B80-10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 C(D)55B40-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40

D-H7 D-H7W D-H7NF D-H7BAL D-A3 D-G39 D-K39 D-C73C D-C80C D-A44 D-G5W/K59W D-G5NTL D-G5BAL D-H7C Bore size (mm) Bore size (mm) HS B A B A B A B A B A B A HS HS HS HS RE A B 20 20 27 27.5 24.5 72 62 15 17.5 12 16 10.5 19.5 14 14.5 9 8.5 20.5 14 25 25 29.5 30 27 74.5 64.5 15 17.5 12 16 10.5 19.5 14 14.5 9 8.5 20.5 14 REC 32 32 33 33.5 30.5 78 68 15 19.5 12 18 10.5 21.5 14 16.5 9 8.5 22.5 16

Model Port size A B C D M N P R B B E F G H J K L AL 58 90 117 117 154 164 195 200 205 M5 X 0.8 11 17 25 35 37.5 40.5 48 48 48 70 103.5 140 150 184.5 189.5 268 282 282 26 56.8 60.8 60.8 65.5 69.5 75.5 75.5 78 25 40 53 53 70 70 90 95 95 29 45 58.5 58.5 77 82 97.5 102.5 102.5 25 30 41 41 50 50 70 70 70 4.5 5.5 7 7 9 9 12 12 12 20 24 35 35 40 40 50 50 50 17.5 22 34.2 34.2 42.2 46.2 55.2 55.2

Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)