), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector)
), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector)
/Lead Wire 300mm), Light/Surge Voltage Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: B (PNP Open Collector), Unit: w/Unit Switching Function, Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: E (Push-turn Locking Lever Type), Vacuum Pressure Sensor: E (Vacuum Pressure Switch, Vacuum 2 Outputs), Output: A (NPN Open Collector), Unit: P (w/Unit Switching Function, Initial Value psi), Lead Wire: G (Lead Wire w/Connector; Length: 2 m; Included)
ID Series ID 2-2 Installation 2 3 IDX-OM-X004 Heatless Air Dryer 2 Transportation / Installation There are two methods depends on model (specified power) ID200 to 600 / 201 to 601 (100/110V specified) Insert the power plug into an outlet of 100/110V AC Do not extend the power cable using power strip and so on. That causes decrease of the voltage and the product cannot be operated.
drain Max. air flow capacity Note 1) 600 L/min(ANR) 120 L/min(ANR) 240 L/min(ANR) Filtration rating 0.01 m (99.9% filtered particle size) Outlet side oil mist concentration Max. 0.1 mg/m3(ANR) [before the saturation of oil: 0.01 mg/m3(ANR) or less0.008 ppm] Compressed air quality class Note 2) ISO8573-1:2010 [1:7:2] 45 cm3 Drain capacity 8 cm3 25 cm3 Bowl material Polycarbonate Bowl guard
0 e 1 New PFA Body 2 New PFA Sensor 3 Super PFA Tube 4 PPS Housing A 5 PPS Housing B 6 PPS Housing C 7 POM Bushing 8 PPS Cap 9 FKM Gasket 10 FKM O-ring 11 SUS304 Thread 12 PVC Lead wire !1 q t i PF2D540 o !0 u !0 !2ywr e !
Calculation example Message for BCC [STX] 01RPV1 [ETX] Calculation ASCII HEX [STX] 02 0 30 1 31 R 52 P 50 V 56 1 31 [ETX] 03 e 65 Code for EXOR from STX to ETX is BCC. Sending message [STX] 01RPV1 [ETX] e 5.7 Command Table 5.7-1 shows the commands which are supported by the product. No response is returned for a request message of a command which is not in Table 5.7-1.
Calculation example Message for BCC [STX] 01RPV1 [ETX] Calculation ASCII HEX [STX] 02 0 30 1 31 R 52 P 50 V 56 1 31 [ETX] 03 e 65 Code for EXOR from STX to ETX is BCC. Sending message [STX] 01RPV1 [ETX] e 5.7 Command Table 5.7-1 shows the commands which are supported by the product. No response is returned for a request message of a command which is not in Table 5.7-1.
Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type PT type 40 VBA VE SMC DIGITAL PRESSURE SENSOR ALM. SET 20 VY1 + G P.SET PPA AL 14-11-19
Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type PT type 40 VBA VE SMC DIGITAL PRESSURE SENSOR ALM. SET 20 VY1 + G P.SET PPA AL 14-11-19
The LEKFS*G slider is the high performance version of the standard LEKFS*E. This motor upgrade improves the maximum work load, maximum acceleration, and maximum velocity compared to the standard motor. Lower cycle times can be realized with the higher performance. All other features of the LEKFS*E are included.
The LEKFS*G slider is the high performance version of the standard LEKFS*E. This motor upgrade improves the maximum work load, maximum acceleration, and maximum velocity compared to the standard motor. Lower cycle times can be realized with the higher performance. All other features of the LEKFS*E are included.
The LEKFS*G slider is the high performance version of the standard LEKFS*E. This motor upgrade improves the maximum work load, maximum acceleration, and maximum velocity compared to the standard motor. Lower cycle times can be realized with the higher performance. All other features of the LEKFS*E are included.
The CLA2 cylinder acts as an air-operated brake with spring-backup. When external position feedback sends a signal to an air valve, the brake is actuated and fast-acting shoes grab the actuator shaft. When pressure is removed, the spring automatically locks the brake onto the shaft. Three locking mechanisms are available: spring lock, air pressure lock and air/spring pressure lock. The CLA2
The CLA2 cylinder acts as an air-operated brake with spring-backup. When external position feedback sends a signal to an air valve, the brake is actuated and fast-acting shoes grab the actuator shaft. When pressure is removed, the spring automatically locks the brake onto the shaft. Three locking mechanisms are available: spring lock, air pressure lock and air/spring pressure lock. The CLA2
PF2A750 PF2A711 PF2A721 PF2A751 IP65 050 -2585 () 3585R.H.() 3F.S.(1535 )5F.S.(050 ) AC1000 V1 50 M(DC500 V ) CERoHS (RcNPTG) 1/81/4 3/8 1/2 ADCNBRSUSPBTPtlrFeNiOFC 250 g 290 g 100 g 1 0.927= 20L/min 3 420 (1 atm)65R.H. 0 (1 atm) 4 mm PVC 1.14 mm AWG23 0.72 mm -36No.PF-OMO0007CN () a(L/min) b(L/min) PF2A710 A 1 10 PF2A750 B 5 50 PF2A711 C 10 100 PF2A721 D 20 200 PF2A751 E
OUT() DC(-) DC(+) PSE57--28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -13No.PS-OMS0004CN-D (A/D ) () 20 2030 -14No.PS-OMS0004CN-D PSE570 PSE573 PSE574 01MPa -100100 kPa 0500 kPa 3.0MPa 600 kPa 1.5MPa oC) oC) (25 ) 2F.S.(050 3F.S.(050 oC) oC) 3F.S.(-1060 4F.S.(-1060 PSE57PSE57--28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 oC) 1.0F.S. 0.5F.S. oC)
SGC200/300/400: Special request X1(SF4-X240) SGC500/600/700: Installed pilot valve VO307 Caution 7 SGC200-OMM0002-F SGC / SGH Series Coolant Valve / Precautions 5 Be sure to read this before handling.
E) Exhaust the air while in the clamped state, and confirm that the clamp arm does not open. 7 - Relation between shim thickness and clamping force 3 Use this figure as a guide as there is a tolerance of about 10% in the clamp cylinder body. When a shim exceeding the peak clamping force position on the graph is inserted, the lock will not be activated when clamped.