S07B5 4(A) 2(B) 5(R1) 3(R2) 1(P) 5 (R1) 4 (A) 1 (P) 2 (B) 3 (R2) y t N.O. + N.O. Component Parts S07C5 2(B) No.
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
M6 thread depth 11 2-M6 thread depth 11 15 15 35 18 15 2-M6 thread depth 11 2-M6 thread depth 11 20 20 A 17 17 40 A 20 20 15 45 60 25 45 60 A Applicable clamp cylinder A Applicable clamp cylinder Part no.
x M6 thread depth 11 (for IA type) 2 x M6 thread depth 11 (for YA type) 15 15 35 18 15 2 x M6 thread depth 11 (for YA type) 2 x M6 thread depth 11 (for IA type) 20 20 17 17 40 A 20 20 19.5 0.2 0.5 15 45 60 25 45 60 A Part no.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
When the product is mounted so that the exhaust port side will be against a wall, use a spacer to secure a clearance of at least 0.039 inch (1 mm). (Fig. 1) For the single unit, PV port and PD port are oriented downward. When it is installed on a working table, use a bracket for single unit (Fig. 2) or secure a space for piping underneath the ports.
Use 2 port valve VNH33. 4.2-33 VNH Dimensions Dimensions (mm) Model Main port 2 port 3 port Pilot port H I A C B D E F G 3 8 3 8 Rc(PT) 1 8 2-Rc(PT) 2-Rc 3-Rc(PT) 3-Rc 50 60 79 90 77 95.5 111 119 60 80 100 115 235.5 265 300 319.5 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A A B A B A B A B 1 2 3-Rc 3 4 3-Rc1 Rc1 4 Rc1 4 Rc1 8 1
ISA-2-1 ISA-2-2 ISA-2-3 ISA-2-4 ISA-2-5 ISA-2-6 ISA-2-7 ISAl-1 ISAl-2/ISAl-1 ISAl-3/ISAl-2 ISAl-4/ISAl-3 ISAl-5/ISAl-4 ISAl-6/ISAl-5 ISAl-6 No.
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
VC 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 24 V 12 V 100 V 200 V 110 V A VDW A VQ B DIN Terminal Circuit with Indicator Light VX2 A AC circuit DC circuit Mounting procedure 1) Hook the mounting hook on the side of the manifold base to the DIN rail. 2) Lift the side of the manifold off the DIN rail and slide it in the
Aluminum alloy 1728 3 Port 3 Position Valve VEX3 Series Working Principle Fig. (1) A R Fig. (2) Closed center Fig. (3) P A 3(R) 3(R) 3(R) 2(A) 2(A) 2(A) 1(P) 1(P) 1(P) This is a 3-port switch valve in which the shaft 7 extending from the driving piston 3 opens/closes a pair of poppet valves 6.
for centralized lead wire ISA-20 Stations Model 2 ISA-21-2 3 ISA-21-3 4 ISA-21-4 5 ISA-21-5 6 ISA-21-6 Regulator AR20-02-1-B -12No.PS-OMW0009-C 2 About this product 2 port solenoid valve VX210X276 Bracket (when control unit fitted) (Nominal size:3 x 8, 2 screws) ISA-17 Spacer with bracket Y200T-A Modular adapter E210-U01 Spacer ISA-18 With O-ring : When a 2 port solenoid valve is connected
0.94 1.02 0.93 1.38 A 1.12 0.96 1.18 1.41 1.31 1.75 A 1.12 0.96 1.18 1.41 1.31 1.75 B 0.37 0.25 0.46 0.46 0.50 0.77 B 0.80 0.53 0.70 0.79 0.70 1.14 A 0.88 0.72 0.94 1.17 1.07 1.52 A 0.88 0.72 0.94 1.17 1.07 1.52 Bore Bore 075 (3/4") 088 (7/8") 106 (1 1/16") 125 (1 1/4") 150 (1 1/2") 200 (2") 075 (3/4") 088 (7/8") 106 (1 1/16") 125 (1 1/4") 150 (1 1/2") 200 (2") Auto Switch Mounting Position
Lead wire with M12 connector (ZS-49-A) M12 female Pin number Description M12 male Pin number 1 L+ 1 2 N.C. or Other 2 3 L3 4 C/Q 4 -97No.PF-OMX0002-B Revision history A: Contents revised in several places. [August 2022] B: Contents revised in several places.
VQ 2 VKF Port size M5 M5 x 0.8 VQZ Regarding VZ120, R port is a supply port.
Analog Output 1 to 5 VDC 4 to 20 mADC 5 20 Analog output [mA] Analog output [V] 1 4 0.6 0 0.2 2 0 2 Differential pressure [kPa] Differential pressure [kPa] Dimensions 2 x 3.5 through Indicator light 24.3 37 27 4.4 4.8 10.7 7.3 25 37 9 3000 15 11.7 10.4 2 x M3 x 0.5 depth 4 With bracket A 37 27 25 38.5 40.9 4.2 11.6 69.5 68 7 20 1.6 A View Bracket 836 Pressure Sensor For General Fluids Series
AS600 (258) AS420 (102) AS600 (258) AS600 (258) AS600 (258) AS800 (586) AS500 (123) 1-A 2-B 1-C 2-A 2-B 1-A 2-B 2-A 2-B 2-B 2-B 2-B 2-B 1-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-A 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 2-B 20 8, 10 1/4 500 9.5 0 1,000 2,000 3,000 Maximum speed Vmax (mm/s) 50 12, 16 1/4, 3/8 1000 19 63 Composed effective area So (mm2) Composed effective area So (mm2)
D-A9 30 Note 1) 15 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 35 + 35 (n 2) 20 + 35 D-M9V 35 20 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 25 + 35 (n 2) 15 + 35 D-A9V 25 15 5 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 D-M9WV D-M9AV 35 + 35 (n 2) 20 + 35 35 20 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 D-C7 D-C80 60 + 45 (n 2) 20 + 45 60 20 5 (n = 2, 3, 4, 5
Series VZ3000/Body Ported Manifold Specifications Manifold Standard Manifold Specifications Type 20 Single base/B mount Common SUP/Common EXH 2 to 20 stations Valve Rc 1 8 Model Manifold type P(SUP)/R(EXH) Valve stations 4(A), 2(B) port location Port size 1(P), 3/5(R) port 4(A), 2(B) port M5 x 0.8, C4, C6 Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size
set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) CKQ D-M9ANote 2) BMA3-040S (A set of a, b, c, e) BMA3-050S (A set of a, b, c, e) BMA3-063S (A set of a, b, c, e) Auto switch Switch bracket (Resin) Transparent (Nylon)Note 1) d e White (PBT) c Switch holder b Auto switch mounting screw a * Band (a) is mounted so that the projected part is on the internal side