Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Tightening torque When installing fittings, etc., follow the procedures below. M5 M5 M5 M5 1)When using SMCs fitting, etc. After tightening by hand, give it additional 1/6 turn with a wrench. (1/4 turn for miniature fittings.)
Cover Cover Turn counterclockwise Turn counterclockwise Pull Pull F.R.L. (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate. (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator.
Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2.
For details about auto switches with pre-wire connector, refer to page 7-9-36. 7-6-2 3 Series CQ2 Compact Cylinder: Standard Type Double Acting, Single Rod Type 12 40 20 50 16 25 63 32 80 100 Bore size (mm) Through-hole (Standard) Mounting Both ends tapped style Built-in magnet Pneumatic Air-hydro (1) M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 3/8 Rc 3/8 M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Screw-in
LVP6 Pilot port thread (fitting) type Material Symbol Nil 1 2 N Thread (fitting) type 6 mm one-touch fitting Rc1/8 M5 x 0.8 NPT1/8 Symbol FKM EPDM O-ring material Nil N Flow sensor Option Drain valve Applicable valve type Symbol Symbol Option N.C. N.O. Double acting Process pump PA PB PA Nil None With flow rate adjustment 1 B A B A B A Air Operated Valve LVP PB N.C. N.O.
2030 10 1% * -7No.PS-OMG0005CN-E 0 01 28 C2 PSE56 0 (01MPa) (1) C2 1 (0-101kPa) 3 (-100100kPa) *PSE200 4 (0500KPa) (15V) 01 R1/8(M5) 28 (420mA) 02 R1/4(M5) C01 Rc1/8 N01 NPT1/8(M5) N02 NPT1/4(M5) A2 URJ1/4 B2 TSJ1/4 ZS-28-C 1 Rc1/4 ZS-31-X175 1 NPT1/4 ZS-31-X186 1 Rc1/8 ZS-31-X188 1 NPT1/8 ZS-31-X189 1 15[V]F.S.=514[V] (1F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1K 1M A/D 5V A/D
(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.
Construction/Parts/Dimensions AN05/10/20 AN15/30/40 No hexagonal part in AN05 and AN10 B Dimensions (mm) B Port size R, NPT A B D Model Sound absorbing material (Resin sintered body) AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 6.5 15 M5 x 0.8 Body (Resin) A 23 1/8 11 A 32 1/4 14 16 Hexagonal flats D 14 45 1/4 16.5 17 58.5 3/8 20 Port size 21 68 24 1/2 2
Caution 2. Through holes 2. Top mount type Guide l Model Bolt Max. tightening torque Nm Body thickness (l mm) Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXS M5 x 0.8 4.4 28 LXS M5 x 0.8 4.4 10 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body. Caution 3.
M5, R(PT) 1/8, R(PT) 1/4 Mounting bracket .M5 style only 3.6-1 Digital Pressure Sensor GS40 How to Order GS40 X202 Digital Pressure Sensor PSE ZSE4 ISE4 Port size Optional M5 (Female) R(PT)1/8 R(PT)1/4 5m-long lead wire X202 M5 01 02 ZSE5 ISE5 ZSE6 ISE6 Accessories B None Bracket (M5 style only) ZSE3 ISE3 GS PS Specifications ISA Model GS40-M5 GS40-01 GS40-02 ZSE1 ISE1 Air or inert gas Fluid
AS120-M5 M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 646 B
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8
M3 ,M5 ,U10/32 R NPT Nil ASN N AQ Model 4 6 8 10 12 5/32"1/4" 5/16"3/8" 1/2" Applicable tubing O.D. (mm) Effective area (mm 2) IN OUT OUT EXH.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
Note 2) For a hydraulic cylinder at 3.5MPa, operate within the maximum tension and compression.
n X 12 12 2 B 4 A 8 2 B 4 A A A B A B A B A B A B A 7 SMC SMC SMC SMC SMC SMC SMC A A A A A A A B B B 2 B 4 A Indicator light 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 P = 25 50.5 P = 25 2 B 4 A 1 44 X Stations 38 26.5 R4.5 12 Connector location on D side (FD) 91 16.5 140 (Single) D side 43.5 50.5 149 (Double) 163 (3 position) 59 96.5 2-5-12 13 Base Mounted Series VQ4000 Plug-in
The bodies are constructed of brass (2-way normally closed, brass or stainless steel is standard). 2-WAY CONDUIT 2-WAY GROMMET 3-WAY GROMMET 3-WAY CONDUIT SERIES 20 A complete line of twoway and three-way valves with a great selection of options. Exceptional proven p e r f o r m a n c e .
O 5/32 P 3/16 U 7/32 R 1/4 A 9/32 S 5/16 T 3/8 V 5/64 B 1/2 C 5/8 D 1 E 1 1/2 Y 3/4 F 2 W 3 D No Option Ports T Metering (1/32 1/8 orif.)
body1 M D P M4 M5 M5 M5 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/2 Size 1 2 6 8 8 8 12.8 19 19 23 P 1 Resin body is not available. 2 Other Options, which can be combined, are A, B, D, E, Z. 3 Electrical entry direction 3 2 x M thread Depth D 90 Standard Note) Resin body is not available.
With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .