(Stations 4 to 7) * SS0700-10A-1 1 set Blanking plate part number (Station 8) * EX600-DXPD 1 set I/O Unit part number (Station 1) * EX600-DYPB 1 set I/O Unit part number (Station 2) Enter in order starting from the first station on the D side.
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 10mm 15mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 15mm 10mm 20mm 20mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt
D-J79C D-F7W/J79W D-F7WV D-F7BAL D-F7F D-F7NTL Manufacture of Intermediate Strokes D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W Method Part number Spacers installed in standard stroke body Refer to standard part number and ordering on page 1.
Auto switch model Bore size (mm) 20 25 32 40 D-M9L D-M9LW D-A9L Note 1) BM2-020 BJ3-1 Note 1) BM2-025 BJ3-1 Note 1) BM2-032 BJ3-1 Note 1) BM2-040 BJ3-1 D-C73C/C80C D-H7BAL D-H7NF BM2-020 BM2-025 BM2-032 BM2-040 D-B54/B64 D-B59W D-G5NTL D-G5NBL BA2-020 BA2-025 BA2-032 BA2-040 D-A3LA/A44A D-G39A/K39A BM3-020 Note 2) BM3-025 BM3-032 BM3-040 Note 1) Two kinds of auto switch mounting brackets
Minimum Stroke For Auto Switch Mounting (mm) D-A7 D-A80 D-A73C D-A80C D-A9V D-A7H D-A80H D-F7 D-J79 D-F9W D-F7W D-J79W D-F7BAL D-F79F D-F9BAL D-F7WV D-F9WV D-F7BAVL D-F7V D-J79C D-M9V No. of auto switches mounted D-A9 D-M9 D-A79W 1 pc. 2 pcs. 5 5 5 10 10 15 15 15 15 20 20 20 10 10 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
Auto switch mounting Bore size (mm) 40 32 25 20 D-A9 D-M9 D-M9W Note 1) Note 1) Note 1) Note 1) 1 BM2-040 1 BM2-032 1 BM2-025 1 BM2-020 2 BJ3-1 2 BJ3-1 2 BJ3-1 2 BJ3-1 D-C7/C80 D-C73C/C80C D-H7 D-H7W D-H7NF BM2-040 BM2-032 BM2-025 BM2-020 D-B5/B64 D-B59W D-G5NTL D-G5NBL BA2-040 BA2-032 BA2-025 BA2-020 Note 1) Two kinds of auto switch mounting brackets are used as a set.
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting
Model Long stroke (mm) 1 Data 25, 50, 75, 100, 125, 150, 200 201 to 350 301 to 400 301 to 450 301 to 800 D-C7/C8 D-B5/B6 D-H7 D-G5NTL 1500 10 mm 15 mm 25, 50, 75, 100, 125, 150, 200, 250, 300 D-B59W 15 mm 20 mm Note 1) Intermediate strokes other than the above are produced upon receipt of order.
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch mounting
Bore size (mm) Stroke (mm) Bore size (mm) Manufacturable stroke range Applicable auto switch Note D25 50 100 75 125 150 175 200 250 300 400 500 12 25 to 150 D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-F7V D-F7/J79 D-J79C D-F7WV D-F7W/J79W D-F7BAL/F7BAVL D-F79F/F7NTL Switch mounting screw (M3 x 0.5 x 8l ) Square nut 12 20 -X BQ-1 20 25 to 300 32 2025 to 400 40 25 to 600 32 40 50 63 Switch
Minimum Stroke for Auto Switch Mounting (mm) D-M9 10 D-M9V 5 D-M9W 15 D-M9WV 10 D-A9 10 D-A9V 5 Bore size (mm) 321, 40 502, 63 No. of auto switch mounted With 1 pc. 10 5 15 15 10 10 With 2 pcs. 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke. 10 Prior to Use Auto Switches
Auto switch model Auto switch 40 50 9 4 7 11 63 40 50 63 -X D-A93 D-M9B D-M9BW D-B54 8 3.5 5.5 10 8 4 6.5 10 D-A93 D-M9B D-M9BW D-B54 Note) qBMA2-040 wBJ3-1 Note) qBMA2-050 wBJ3-1 Note) qBMA2-063 wBJ3-1 Individual -X BA-04 BA-05 BA-06 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)
30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the
D-F5 D-J5 D-F5BAL D-F59F D-Z7, Z80 D-Y59, Y69 D-Y7P, Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5
Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) Note 1) BMA3-020 Note 1) BMA3-025 Note 1) BMA3-032 Note 1) BMA3-040 Note 1) BMA3-050 Note 1) BMA3-063 CJ1 Note 2) BMA3-020S Note 2) BMA3-025S Note 2) BMA3-032S Note 2) BMA3-040S Note 2) BMA3-050S Note 2) BMA3-063S D-M9A(V) CJP D-C7/C80 D-C73C/C80C D-H7 D-H7W D-H7NF D-H7BA D-B5/B64 D-B59W D-G5/K59 D-G5W/
Minimum Auto Switch Mounting Stroke (mm) D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W D-F7V/J79C D-F7WV/F7BAVL D-F7/J79 D-F7W/J79W D-F7BAL/F7NTL D-F79F D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL DNumber of auto switches -X Individual -X 1 pc. 20 20 20 20 2 pcs. 859 Series RLQ Operationg Range (mm) (mm) Auto switch type Bore size Auto switch type Bore size 32 40 50 63 32 40 50 63 D-A9/A9V
Auto Switch Mounting Stroke for 8 Stroke (mm) Note Applicable auto switch Mounting condition Piping direction 2 pcs. on same side D-A9 Standard piping type (1) (2) D-M9, D-M9W (2) D-A9V D-A9 1 pc. each on 2 sides (2) D-M9, D-M9W (2) 2 x port size D-A9V D-A9 Axial piping type (2) 2 pcs. on same side D-M9, D-M9W (2) D-A9V D-M9V, D-M9WV D-F8 D-A9 (2) 1 pc. each on 2 sides D-M9, D-M9W (2) D-A9V
Note 1) Lead wire length Z: Auto switches applicable for 5m Reed switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: All models are produced upon receipt of order (standard procedure). However, this does not include D-F9, F9V and F7WV.
3-4 . 3-2 3-5 . 3-2 3-6 . 3-2 4 4-1 . 4-1 4-2 . 4-1 4-2-1 . 4-1 4-2-2 . 4-1 4-2-3 . 4-1 5 5-1 . 5-1 6 6-1 . 6-1 6-2 GWP . 6-2 IDFA Series 1 6-3 . 6-3 6-4 . 6-4 6-5 . 6-5 7 A 7-1 . 7-1 7-2 . 7-1 7-3 . 7-1 7-4 . 7-1 8 C 8-1 . 8-1 8-2 . 8-1 8-3 . 8-1 9 K 9-1 . 9-1 9-2 . 9-1 10 L 10-1 . 10-1 10-2 . 10-1 10-3 (ADH4000-04) . 10-2 10-4 . 10-2 10-5 . 10-2 11 11-1
I C o n s t a n t Function Sets integral time used for PID control/ M O D E < 1 5 0 s e c 5.5 How to operate 5-10 A_HEC-OM-K001-1.7 Chapter 5 Operation <6> D constant setting: Mode indication D Constant Default value: 0 sec. Setting range 0.0 to 99.9 sec. Indicated contents D constant (Derivative time) D Constant indicates that it is D constant setting mode.