ZSE20C: ZSE20C, Rated Vaccum Range: F (-100 to 100 kPa), Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
ZSE20C: ZSE20C, Rated Vaccum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead
ZSE20C(F) is UL/CSA, CE and RoHS compliant.
1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5 DIN F02(G1/4)DIN -12No.PF-OMJ0005CN-I LED UP) (DOWN) (OUT2) (OUT1) SET) (OUT ) (IN ) (OUT1
Accuracy may vary by 2 to 3% if the customer removes or replaces the piping port. -9No.PF-OMO0005-F Model Indication and How to Order -10No.PF-OMO0005-F Option1 NIL W N With lead wire with connector (2 m) With lead wire with connector (2 m) No lead wire + Connector cover (Silicone rubber) Option 2 NIL R S No bracket With bracket With bracket (Without flow adjustment valve) (With flow adjustment
7 A*8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J (
Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Do not use a cable longer than 30 m. Wire the DC (-) line (blue) as close as possible to the power supply.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
Secondary battery capability is achieved by providing removing the bracket munting inserts found on the standard ZSE20C. 25a-ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: Rc1/8, Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
ZSE20C(F) is UL/CSA, CE and RoHS compliant, with an IP65 rating.