Output 3 goes ON if "C" is turned ON, only when output 1 and output 2 are in an ON state. If either "A" or "B" is OFF, output 3 does not go ON even if "C" is turned ON.
Output 3 goes ON if "C" is turned ON, only when output 1 and output 2 are in an ON state. If either "A" or "B" is OFF , output 3 does not go ON even if "C" is turned ON.
L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27
1 P, S, T PC23 *COP2 Function selection C-2 S PC24 *COP3 Function selection C-3 S PC25 *COP4 Function selection C-4 P, S PC26 ALDT Detailed setting of overload tough drive P PC27 OSCL Detailed setting of vibration tough drive P, S PC28 CVAT Detailed setting of instantaneous P, S power failure tough drive PC29 *COP5 Function selection C-5 P, S, T PC30 *COP6 Function selection C-6 S PC31 SC4
Type 32P How to Order 10--SS5YJ3--32P-07 -C4 Applicable connector assembly Refer to page 505.
Vacuum switch unit Filter unit Release flow rate adjusting needle Manual operation Vacuum switch Electrical entry Ejector exhaust Electrical entry PV/V port size Pilot valve Components Vacuum switch unit Valve unit N.C. type Ejector unit ZX1 1 10 5 L Z E C K1 L Vacuum switch unit Ejector unit 1 10 L Z E C K3 5 ZX1 Valve unit N.O. type Vacuum switch unit ZX1 1 10 E C Ejector unit CE compliant
Note 2) The withstand voltage specifications for the wiring unit section is JIS C 0704, Grade 1 or its equivalent. Note 3) CE-compliant: For DC only.
For ejector system Nil L Grommet (0.6 m) S 0.3 to 0.7 B 0.5 to 1.2 Combination of supply valve and release valve Grommet (3 m) C Connector (0.6 m) CL Connector (3 m) CN Without connector Unit for replacement Pilot valve Voltage Manual operation Light/Surge voltage suppressor Electrical entry (2) Manifold base (5) Vacuum switch unit 15 C 0X ZSE2 D 05 ZZX1 R A C Piping specifications Stations
Note 2) The withstand voltage specification for the wiring unit section is JIS C 0704, Grade 1 or its equivalent.
Wear ring number Wear ring number 40 C1A040-07-305B 50 C1A050-07-306B 63 C1A063-07-307B 80 C1A080-07-308B 100 C1A100-07-309B C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2. Storage of seals C a u t i o n Store seals in sealed packaging such as polyethylene bag and place it in a box.
) ST(I) (07 ) ST(O) ON/OFF (07 ) ST(I) ON/OFF (07 ) ST(O) (07 ) (SI ) -52No.EX-OMN0035CN-A OFF (LED 0707) ON (LED 07) ()07 ON (LED 07) ()07 (SI ) -53No.EX-OMN0035CN-A EX600-DMPE EX600-DMNE EX600-DMPF EX600-DMNF PNP NPN PNP NPN D-sub(25 ) No.4-40 UNC (32 ) 8 () DC24 V Class22 A 2 A/ 0.5 A/ 2 A/ 4.7 k 5 mA ON /ON 17 V /3 mA (NPN 24 V ) (PNP 0 V ) OFF /OFF 5 V /1 mA (NPN
Grease pack part number: GR-D-005 (5g), GR-D-010 (10g), G-D-100 (100g) Table 13 Wear ring Wear ring number 40 C2A40-07-305B 50 C2A50-07-305B 63 C2A63-07-305B 80 C2A80-07-305B 100 C2AA0-07-305B C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2.
Grease pack part number: GR-S-010(10g) , GR-S-020 (20g) B Wear ring number 40 C1A040-07-305B 50 C1A050-07-306B 63 C1A063-07-307B 80 C1A080-07-308B 100 C1A100-07-309B C a u t i o n The seal is not delivered in sealed packaging for storage independently, so it must be used within 1 year. 3-3-2.
Norte Parque Industrial Valle Grande, Lampa Santiago, Chile TEL: 02-270-8600 FAX: 02-270-8601 SWEDEN SMC Pneumatics Sweden AB Ekhagsvgen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 ARGENTINA SMC Argentina S.A.
2 U seal Retaining ring for hole type C HNBR Tool steel y !
Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23
ON, even though C turns ON, the output 3 will not be turned ON. 1.
D J K P L W (without supply/release valve, without switch, pressure sensor) KJR KJRN L to L3 C to L3 06 P 560 56 P to J N 00 i Optional Specifications/Functions/Applications Note 19) Q 08 Type Function/Application L to N Symbol Nil A 07 ZK2 07 Without option B 10 09 Bracket P to N C to N Use when a single unit is mounted to the floor in an upright position is requested.
Fluid Air/Inert gas Operating pressure 100 kPa to 1.0 MPa 5 to 60C (No freezing) Ambient and fluid temperature Flow characteristics 2 (NO) 3 (OUT) 1 (NC) 2 (OUT) 1.4 1.4 0.15 0.2 0.29 0.29 C [dm3/(sbar)] b Cv Lubrication Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)