Vacuum (V) and exhaust (E) port should not be sealed simultaneously.
Also, the surge pressure must be under the maximum operating pressure.
The trunnion bracket must be ordered separately.
It will be locked set in a (Passage: PA) state. Turn the manual override counterclockwise by 180 to set the mark to B and press it in the direction indicated by the arrow. It will be reset in a (Passage: PB) state. (It is reset when shipped.)
Note 2) Pressure switch cannot be mounted later on non plug-in type. 4 V or less 0.2 to 0.9 MPa Non plug-in type Caution Air filter with auto-drain or manual drain must be mounted with the air filter at the bottom. 3-5-24 25 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2000 How to Order VV5FR2 10 1 08 AP 01 Air release valve coil rating Series VFR2000 Manifold
/G59F/G5NTL Double clevis CA1-D04 CA1-D05 CA1-D06 CA1-D08 CA1-D10 BA-04 BA-05 BA-06 BA-08 BA-10 When ordering foot brackets, 2pcs. should be ordered for each cylinder.
The OUT direction can be mounted up to 90 to the left or right.
Style Inch Millimeter Elbow Universal 2 3 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 23 04 06 08 10 12 03 05 07 09 11 13 4 6 8 10 12 Control Meter out Meter in 0 1 1/8" tube should be used.
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
Note1) Metric size Inch size Note 3) 23 3.2 Note 2) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" Stainless steel type (Stainless steel 303) 04 4 06 6 08 8 10 10 12 12 16 16 Note 1) The material can be visually identified by color of the release button. Stainless steel type: White Note 2) White is also used for inch size.
Ordering: Add the word Bolt in front of the bolts to be used.
06 FH440-08 FH440-10 FH440-12 FH640-03 FH640-04 FH640-06 FH640-08 FH640-10 FH640-12 3/8 3/8 10 10 FH441-04 FH441-06 FH441-08 FH441-10 FH441-12 FH441-16 FH441-20 FH441-24 FH641-04 FH641-06 FH641-08 FH641-10 FH641-12 FH641-16 15 (1/2B) 15 (1/2B) 1/2 1/2 20 20 20 (3/4B) 20 (3/4B) 3/4 3/4 50 50 Max. 21 MPa 25 (1B) 25 (1B) 1 1 80 80 Max. 7 MPa 32 (1 1/4B) 32 (1 1/4B) 1 1/4 1 1/4 120 120 40
Ordering: Add the word Bolt in front of the bolts to be used.
How to order: Add "Bolt" in front of the bolts to be used. Example) Bolt M5 x 50l 4 pcs.
Flow rate can be controlled numerically with the indicator window.
T unit Can be connected with PLC I/O card for serial transmission.