SMC Corporation of America
Elite Part Number Search
Search Results "ZH13DSA-08-F02-10"

Piping/weight specifications Product No. 02(L) N02(L) F02(L) C01(L) A2(L) B2(L) Port size R1/4 NPT1/4 G1/4 Rc1/8 URJ1/4 TSJ1/4 fluid contact Materials in part Pressure-sensing part Pressure sensor: SUS630, Fitting: SUS304 Body (Rear piping) 51 g 51 g 48 g 47 g 54 g 46 g Weight Body (Bottom piping) 77 g 78 g 74 g 65 g 81 g 72 g Lead wire with connector +39 g Leakage 1 x 10-5Pa m3/s 1 x 10

Display/set pressure range -0.105 to 1.050 MPa -0.105 to 1.680 MPa Display/min. set unit 0.001 MPa Proof pressure 1.5 MPa 2.4 MPa Power supply Used as switch output device 12 to 24 VDC 10% with 10% voltage ripple or less (p-p) voltage Electric spec.

If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute. The voltage drop across the product (and therefore not applied to the load), when the switch output is ON. The voltage drop will vary with load current, and ideally should be 0 V.

For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. Unit s selection function is not available for fixed to SI units type.

Description IR1000 IR3000 IR3020/3120 IR2020/2120 IR3010 IR1020 IR2000 IR2010 IR1010 Bracket Pressure gauge P36203018 P36202028 P36201023 G43-2-01 G43-4-01 G43-10-01 G43-4-01 G43-10-01 G33-4-01 G33-10-01 G43-2-01 G33-2-01 Accuracy 3% (Full span) 14-5-7 7 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 q i o !4 q o i !

ISE70 (Air) ISE75 (Fluid) ISE75H (Fluid) Rated pressure range 0 to 1 MPa 0 to 10 MPa 0 to 15 MPa Set pressure range -0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa Withstand pressure 1.5 MPa 30 MPa 45 MPa Set pressure resolution 0.01 MPa 0.1 MPa Fluid Air, inert gas and incombustible gas Fluid which has no corrosive effect on SUS304, SUS430, SUS630 Power supply voltage 12 to 24 VDC 10%, ripple

For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. Unit s selection function is not available for fixed to SI units type.

Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: 08 (One-touch Fitting ø8), VAC: 02 (Screw-in Rc 1/4), EXH: 10 (One-touch Fitting ø10), Accessories: NS (w/o Standard Bracket, w/Silencer)

Nozzle Diameter: 13 (ø1.3mm), Vacuum Pressure: S (-90 kPa), SUP: 08 (One-touch Fitting ø8), VAC: 02 (Screw-in Rc 1/4), EXH: 10 (One-touch Fitting ø10), Accessories: S (w/Standard Bracket, w/Silencer)

Nozzle Diameter: ø1.3mm, Vacuum Pressure: -90 kPa, SUP: One-touch Fitting ø8, VAC: Screw-in Rc 1/4, EXH: One-touch Fitting ø10, Accessories: w/Standard Bracket, w/Silencer

Main Body Shape: Pipe Type, Additional Function: Silencers, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 84, Vacuum Port Connecting Port Shape: Rc1/4, Vacuum Port One-Touch Fitting Size: -, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø8, Application: Manifolds, Operating Pressure Range(MPa): 0.1~0.6, Operating Temperature

Nozzle Diameter: ø1.3mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: One-touch Fitting ø8, VAC: Screw-in G1/4, EXH: One-touch Fitting ø10, Accessories: -

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

MU-D02 MU-D03 MU-D04 MU-D05 CJ 7 10 10 14 CI 17 22 27 32 CH 11 13 13 17 CF 4 7 10 12 CE 3.5 3.5 3.5 5.5 CB 23 27 31 37 CA 53 67 85 103 DJ 7 10 10 14 DI 17 22 27 32 DH 11 13 13 17 DF 4 7 10 12 DE 3.5 3.5 3.5 5.5 DB 23 27 31 37 DA 53 67 85 103 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no.

(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.

Display/set pressure range -2.5 to 52.5 MPa Display/min. set unit 0.1 MPa Proof pressure 75 MPa Power supply Used as switch output device 12 to 24 VDC 10% with 10% voltage ripple or less voltage Electric spec.

F_1 and F_2 have setting ranges of 0-90%F.S. and 10-120%F.S., respectively. However, the set pressure exceeds rated output; 100F.S. is out of warranty. (refer to Fig.2,3) The values are necessary to satisfy F_1 + 10%F.S. < F2. If not, the previous values are reflected in this function. Default of Zero adjusting: 0x0 Bit Bit 13 (It is Bit 12 up to 100%.)

Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)