SMC Corporation of America
Elite Part Number Search
Search Results "ZCDUKC10-15D-A93L"

ZSE2-0R-15 Air 0 to 101 kPa 3% or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) Open collector 30 V, 80 mA Lights up when ON 17 mA or less (when 24 VDC is ON) 0.2 MPa Fluid Setting pressure range Hysteresis Compact size: 39H x 20W x 15D (except the connecting portion) ZX Temperature characteristics Improved wiring: Connector style Operating voltage

Do not expose it to direct sunlight. 13-2-12 12 Vacuum Module: Ejector System Series ZX Vacuum Pressure Switch Unit/Vacuum Pressure Switch: ZSE2-0X Vacuum Pressure Switch Quick response: 10 ms Compact size: 39H x 20W x 15D (except the connecting portion) Improved wiring: connector type Uses a carrier diffusion semiconductor pressure sensor ZSE2-0X Air 0 to 101 kPa 3% Full span or less 3%

This is a legacy product, and replaced byCDJP2F6-15D-B-A93S

This is a legacy product, and replaced byCDJP2B10-15D

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 25mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 10mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 20mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 30mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.13 to 0.7, Specification: Built-in magnet, Port thread

Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Cap Piping/Male Thread, Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 25mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Cap Piping/Male Thread, Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 10mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Cap Piping/Male Thread, Bore Size: 10mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 20mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -

This is a legacy product, and replaced byNCDRA1BS50-90CZ-A93L NCRA ROTARY ACTUATOR. NCRA 50 SGL/DBL ROD W/AUTO-SW. ACTUATOR. 50MM NCRA DBL-ACT AUTO-SW. 3.30000 lb. NE.

This is a legacy product, and replaced byMGPM20-125Z-A93L MGP COMPACT GUIDE CYLINDER. CYL, COMPACT GUIDE, SLIDE *LQA. ACTUATOR. 20MM MGP SLIDE BEARING. 3.57060 lb. HM.

F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A93 (Example) A93L

Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil (Example) A93 3 mL A93L

switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols: 0.5 mNil (Example) A93 3 m L (Example) A93L

Load voltage Auto switch model Electrical entry direction Indicator light Electrical entry Special function Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12V In-line Yes Grommet 24V 100V 12V Reed switch 2-wire Relay, PLC A93 3-wire (NPN) M9N Yes Grommet 24V Solid state switch Relay, PLC 2-wire 12V M9B Lead wire length symbols: 0.5mNil (Example) A93 3 m L (Example) A93L

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.