Rc Special voltage With light Without DIN connector (With surge voltage suppressor) G 24 VAC 12 VDC 48 VAC NPT 1K 1L Rc 220 VAC 240 VAC Applicable to air and water (VXN<2) Conduit terminal 1M 1W (With surge voltage suppressor) 24 VAC 12 VDC 48 VAC 1N 1P 1Q 1R 1Y 1S 1T 2A 2B 2C 2D 2E 2F Enter symbols in the order below when ordering a combination of electrical option, other option. 220 VAC
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, F19, PF3W, "DIGITAL FLOW SWITCH
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: Flow Adjustment Valve, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
PF3W5 -1T (Analogue 1 to 5 V type: With temperature sensor) Tighten to the specified torque for piping. The tightening torque for connection threads is shown in the table below. 1 DC(+) Safety Instructions Nominal thread size Tightening torque 1 3 2 NC/Analogue output (temperature) The POWER indicator (Green) turns on, and the FLOW indicator flashes according to the flow rate.
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
MSU OTHER SIZE RATING. .41424 lb. 1T.
MSU OTHER SIZE RATING. .42990 lb. 1T.
MSU OTHER SIZE RATING. .55115 lb. 1T.
MSU OTHER SIZE RATING. .55115 lb. 1T.
MSU OTHER SIZE RATING. .51826 lb. 1T.
MSU OTHER SIZE RATING. 1.60736 lb. 1T.
MSU OTHER SIZE RATING. 1.43300 lb. 1T.
MSU OTHER SIZE RATING. .53973 lb. 1T.