. -61: Oil Resistant, Flexible Cable Specifications .
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.
Without light SY100-61-1 With light Rated voltage Rating symbol 24V 12V 100V 200V 110V 220V Part No. SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution 24VDC 12VDC 100VAC 200VAC 110VAC 220VAC How to Use the DIN Terminal Connector (SY5000/7000 only) Connection 1.
20.9 55 22 57.4 5/16 3/8 KQU09-U02 17.46 15.2 51.5 15.2 45.5 18.5 6 12 38 KQU12-U03 22 20.9 61 20.9 55 22 57.4 3/8 1/4 KQU11-U02 19.05 17.9 56.5 17.9 50.5 21 7 12 12 KQU12-U04 22 20.9 62.5 20.9 54.5 22 57.4 3/8 3/8 KQU11-U03 19.05 17.9 56.5 17.9 50.5 21 7 3/8 1/2 KQU11-U04 22.23 17.9 59 17.9 51 21 7 1/2 1/4 KQU13-U02 22.23 21.7 61 21.7 55 22 9.6 1/2 3/8 KQU13-U03 22.23 21.7 61 21.7 55 22
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 (14.5) L
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Rating symbol 24V 12V 100V 200V 110V 220V Rated voltage 24VDC 12VDC 100VAC 200VAC 110VAC 220VAC SY3120-5LOZ-M5 SY100-68-A-20
. -61: Oil Resistant, Flexible Cable Specifications . Technical Data. Plug-in Connector Assembly/ How to Use DIN Terminal.
Without light SY100-61-1 With light Model no. SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Voltage symbol 24 V 12 V 100 V 200 V 110 V 220 V Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC How to Use DIN Terminal Caution Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block. 2.
) 60.5 (70.5) 40.5 (40.5) 50 (50) 50.5 (50.5) 52 (52) 61 (61) 70.5 (70.5) 32.2 (39.4) 33 (43) 35 (47) 39 (49) 44.5 (54.5) 54 (64) 56.5 (66.5) 58 (68) 71 (81) 84.5 (94.5) 6 to 29 6 to 29 6 to 49 6 to 49 6 to 99 6 to 99 11 to 99 11 to 99 (mm) ( ): Denotes the dimensions of auto switch type.
149 61 149 61 149 4.0 5.0 3.0 94.2 235.8 94.2 235.8 94.2 235.8 Mounting of Auto Switch When mounting an auto switch, insert it into the cylinders switch groove from the direction shown in the drawing to the right.
Warranty and Operating Instructions Intermediate stroke Spacer-installed type Dimensions: Series CQ2 (mm) Double acting, Single rod Symbol B A Mounting and Auto Switches Made to Order Stroke 51 to 54 56 to 59 61 to 64 66 to 69 76 to 79 81 to 84 86 to 89 91 to 94 51 to 54 56 to 59 61 to 64 66 to 69 76 to 79 81 to 84 86 to 89 91 to 94 Bore size 32 40 50 63 80 100 95 101.5 103.5 109 118.5 130
Standard (mm) Bore size (mm) Stroke range (mm) Without auto switch With auto switch A B A B 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 58 68 71 81 84.5 94.5 42 52 51 61 60.5 70.5 68 52 63 80 81 61 100 94.5 70.5 (mm) C D E H J K L M N O P Q W Z Bore size (mm) 63 80 100 20 77 M10 x 1.5 7 17 8 9 14 depth 10.5 1/4 15.5 84 19 15 60 25 98 M16 x 2.0 6 22 10 11 17.5 depth 13.5 3/8 18 104
Dimensions [mm] Model F G GB H HB I J M N NN Z ZZ MXQ8C-10Z 25 15 9 25 37 10 26.5 68.5 4 2 51 61 MXQ8C-20Z 25 22 16 28 40 14 32.5 78.5 4 2 61 71 MXQ8C-30Z 26 26 40 14.5 42 88.5 6 3 71 81 MXQ8C-40Z 32 14 27 31 55 20 52.5 104.5 6 3 87 97 MXQ8C-50Z 46 16 54 29 55 37 62.5 131.5 6 4 114 124 MXQ8C-75Z 50 15 56 30 55 10 91.5 156.5 6 4 116 126 71 Air Slide Table/Single Side-ported Type MXQC Series
P. 64 15-2-61 3 Series H/DL/L/LL Male Connector: H H1 (width across flats) H2 (width across flats) Applicable tubing O.D.
Stroke 5 10 15 20 25 30 40 50 75 100 Y 12.5 12.5 15 15 20 20 15 17.5 25 30 Q 20 20 20 30 E 58.5 61 51 63.5 61 63.5 63.5 66 71 73.5 D I M E N S I O N S W I T H F L A N G E 32 M M (See table above) This drawing: 15 stroke, 90 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 !
AC55 AC60 KSV KTV KSTV ST SV STV TV L2 61 76 76 99 Attachment Model L1 41.5 55 55 72.5 L2 43 57 57 75 L3 57 74 74 95 L4 43 57 57 75 L1 41.5 55 55 72.5 L2 61 76 76 99 L3 43 57 57 75 L4 43 57 57 75 L1 41.5 55 55 72.5 L3 57 74 74 95 L4 43 57 57 75 L1 41.5 55 55 72.5 77.5 93 98 98 L2 61 76 76 99 104 124 124 129 L1 41.5 55 55 72.5 77.5 93 L2 43 57 57 75 80 96 L3 57 74 74
ZP3E-100UM ZP3E-80BM ZP3 61 50 ZP3E ZP3E Part no. ZP3EU-F5-TB12 [Weight: 189 g] Part no. ZP3EU-F6-TB12 [Weight: 236 g] ZP2 ZP2V 26 18 26 18 ZP Width across flats 22 M12 x 1.75 M12 x 1.75 Width across flats 22 ZPT ZPR 6 27 19 52 6 27 19 52 11 11 XT661 32 32 4 4 11.11) 11.11) 30 30 (Rotating angle) (Rotating angle) Applicable pad part no.
L2 3.5 Approx. 300 (Lead wire length) S070 L1 VQ (Station 1) (Station n) (Light/Surge voltage suppressor) VKF VQZ 41.5 [48.5] + + + + + VZ 26.1 VS 13 VFN L plug connector (L) M plug connector (M) M8 connector (WO) Approx. 300 (Lead wire length) 1.9 1.9 1.9 48.7 [50.9] 43.7 58.5 [60.7] 50.2 57.6 52.6 [59.6] Approx. 300 (Lead wire length) 28.5 M8 x 1 46 26.1 41.5 [48.5] Refer to page 4-4-61
Note 2) Add -61 at the end of the part number for the flexible lead wire.