SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-08-DO-00N"

Do not disassemble the product or make any modifications, including additional machining. 6. Do not use tools such as pliers to rotate the knob. AS-T It can cause idle rotation of the knob or damage. It may cause human injury and/or an accident. ASP 7. Verify the air flow direction. 4. The flow rate characteristics for each product are representative values.

Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with

2Lead wire assembly ZK2 CHS 04 A Applicable stations 03 For 3-station manifold 08 For 8-station manifold 128 JSY3000 Series How to Increase Manifold Stations: Vacuum Ejector Manifold for JSY3000 Caution Connect the lead wire assembly to the positions shown in the diagram below. 1) After inserting each pin, confirm that the pin is locked by lightly pulling the lead wire. 2) Do not pull

DF 4-DT DH DS DA DL 4-DL B 90 DU DU DO DO DC Rotation DE Bore size (mm) A B A + B + 90 A 40 to 100 12 60 162 Note) This assembly drawing is provided as a reference.

D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A KPGR04-06 KPQR04-06 3 39.4 20.1 6 4 M A L 10.4 18 4 4 KPGR04-08 KPQR04-08 41.9 20.2 4 8 KPQR06-08 KPGR06-08 20.8 4 42.5 6 12.8 19.5 10 10 KPQR06-10 KPGR06-10 5 21.2 45 Applicable fitting size d 10 KPGR08-10 KPQR08-10 5 47 23.2 8 15.2

Do not operate in locations where vibration or shock will occur. 4. Do not operate in a location near a heat source or where radiated heat will be received. 16 Series AS-FG/ASD-FG Specific Product Precautions Be sure to read before handling. Refer to pages 15 and 16 for safety instructions and flow control equipment precautions.

Do not drop or bump the product. Dropping or bumping while handling may cause damage to the product. 5. Lead wire dimensions Pressure Supply Warning Covering: 3.4 Insulator: 1.1 Conductor: 0.64 1. Do not use the switch with corrosive gas or liquid. Do not use the switch with corrosive gas or liquid. Such gas or fluid may cause damage to the switch. Operating Environment Warning 2.

Do not bend or pull cables repeatedly, and do not place heavy objects on them or allow them to be pinched.

D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A 39.4 20.1 3 KPQR04-06 KPGR04-06 6 4 10.4 18 4 4 M A L 41.9 20.2 4 KPQR04-08 KPGR04-08 8 42.5 20.8 4 KPQR06-08 KPGR06-08 6 12.8 19.5 10 10 45 21.2 5 KPQR06-10 KPGR06-10 Applicable fitting size d 10 47 23.2 5 KPQR08-10 KPGR08-10 8 15.2

D Plug-in Reducer: KPQR, KPGR Applicable tubing D Effective area mm Note 1) D Model L TPH TPS Applicable fitting size d Applicable tubing O.D. mm Weight g M A 39.4 20.1 3 KPQR04-06 KPGR04-06 6 4 10.4 18 4 4 M A L 41.9 20.2 4 KPQR04-08 KPGR04-08 8 42.5 20.8 4 KPQR06-08 KPGR06-08 6 12.8 19.5 10 10 45 21.2 5 KPQR06-10 KPGR06-10 Applicable fitting size d 10 47 23.2 5 KPQR08-10 KPGR08-10 8 15.2

Do not use a shock absorber together with air cushion.

Dept. code 24 Manifold Specification Sheet Series VQC2000: Base-Mounted Type/Plug-in Unit q How to order manifolds VV5QC 2 1 08 FD1 B C8 F P T Kit / / 1 2 3 8 VV5QC 2 1 08 SDQ B C8 S Kit Fill out for I/O serial kit only.

Do not use the cylinder in the locked state to sustain a load that involves impact.

Do not disassemble the product or make any modifications, including additional machining. 6. Do not use tools such as pliers to rotate the knob. AS-T It can cause idle rotation of the knob or damage. It may cause human injury and/or an accident. ASP 7. Verify the air flow direction. 4. The flow rate characteristics for each product are representative values.

AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 Adjustment of Cushion Effect (Smooth Start-up, Soft Stop) Caution Since the external slider and piston slider are directional for size 10, refer to the drawings below when performing disassembly or maintenance.

Wiring Specs 08 08 Applicable up to 8 Solenoids 26 Pole (P) Connector Symbol Station Note 02 2 Single .. ..

76.5 77 78 8 6 KM14-06-08-01S-3 31 39 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 43 44 66 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 94 95 98.5 88 89 90.5 10 8 KM14-08-10-02S-3 47 19 70 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19 15.2 52.6 18.5 12.8 21 KM15 Precautions

AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4. Use caution to the direction of the external slider and the piston slider. Since the external slider and piston slider are directional for size 10, refer to the figures below when performing disassembly or maintenance.