. \ I I Regulators r' SUP. I Electro-pneumatic , / , ' ' Control signal t , / ' a Mist separator Controller Analog control tleHro-Pltsulnalic Regulalnn rTUz000/3 $rucilicflior$ Standard s . : j 1w301 Minimum supply pressure Set pressure + 0.1MPa Maximum supply pressure 0.2MPa 1.0MPa Regulating pressure rang 0 005 to 0.1 MPa 0.005 to 0.5MPa | 0.005 to 0.9MPa Voltage 24YDC !
For positive pressure 80 ISE 02 N M For vacuum/ compound pressure M 80 ZSE 02 N Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø6, Lock Nut: J (Round)
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø8
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø6
Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø8, Lock Nut: J (Round)
Blue DC(-) DIN rail mounting (using ZS-33-R ) Mount the DIN rail mounting parts using DIN rail mounting screws and joint screws supplied. The required tightening torque of the DIN rail mounting screws and joint screws is 0.40.05 Nm. Connector for electrical connections.
To "F02" by usi ng t he and keys. ( di spl ayed al t ernat el y) Press Skey. Set t he SEN SI TI VI TY by usi ng t he and keys. ( bl i nk and change t he m ost ri ght di gi t ) Press Skey.
Number of Ports: 3 Port, Body Option: Side Mounting, Port Size: F02 (G 1/4), Actuator Type: 32 (Push Button, Extended), Suffix: R (Red)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: F02 (G1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M)
This is a legacy product, and replaced byAR20-F02-R-B, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, DA, AR MASS PRO 1/4 MODULAR (PT), .59524 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR201/8, 1/4BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital pressure switch(except
This is a legacy product, and replaced byAC20-F02-B, F/R/L COMBO MODULAR, AIRLINE EQUIPMENT, AC MASS PRO, DA, AC MASS PRO 1/4 MODULAR (PT), 1.65346 lb
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)