SMC Corporation of America
Elite Part Number Search
Search Results "V114-4L"

Switch mounting screw Slotted head set screw (M2.5 x 4l) 27.6 1.5 2.5 5.7 3.4 l Operating range (see table below) 12.5 Most sensitive position Note) This is a standard including hysteresis, and is not guaranteed. There may be large variations depending on the surrounding environment (variations as much as 30%).

Straight bladed watchmaker's screwdriver 5 to 6 Switch mounting screw M2.5 X 4l Hysteresis Auto switch Switch contact point (ON) Switch resistor point (OFF) Max. hysteresis mm Auto switch D-F9BAL Note) Use a screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw. The tightening torque should be about 0.6 to 1.2 inlb.

MXH16 MXH20 Steel ball A High carbon chrome bearing steel 10 Includes 1 each of and 2 each of Rod seal 21 Steel ball B 11 High carbon chrome bearing steel 22 Piston seal 21 23 MXH6-PS MXH10-PS MXH16-PS MXH20-PS NBR Piston gasket 23 Gasket 24 24 32 Compact Slide MXH Series Dimensions 6 LT (mm) 15 9 J-M3 x 0.5 Depth 6.5 LA 8 LB Plug for port (hexagon socket head set screw) 4-M5 x 0.8 x 4l

For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire

1 Steel ball B Gasket NBR 8-2-14 13 Compact Slide Series MXH Dimensions: MXH6 LT 15 9 MX J-M3 x 0.5 Depth 6.5 LA LB 8 MTS MY Guide rail width 5 3-M4 x 0.7 through Bottom hole dia 3.3 6-6 counterbore depth 3.3 4-M3 x 0.5 Depth 5.5 Plug for port (Hexagon socket head set screw) 4-M5 x 0.8 x 4l CY 2-M5 x 0.8 6.5 5 4-M3 x 0.5 Depth 4.8 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

flow rate L/min 4 15 30 40 (1.1 [gal]/min) (4.0 [gal]/min) (7.9 [gal]/min) (10.6 [gal]/min) Facility water minimum necessary flow rate L/min 10 15 25 40 (2.6 [gal]/min) (4.0 [gal]/min) (6.6 [gal]/min) (10.6 [gal]/min) Operating temperature range C 20 to 90 Temperature stability *1 C 0.3 Circulating fluid *2 Ethylene glycol solution60% 0.35 / 0.55 0.45 / 0.65 0.40 / 0.60 0.35 / 0.55 (At 4L

Switch mounting screw Slotted set screw (M2.5 x 4l) 27.6 1.5 2.5 Use a contact protection box in any of the above situations, as the life of the contacts may otherwise be reduced.

Switch mounting screw 27.6 1.5 Slotted set screw (M2.5 x 4l) 2.5 Use a contact protection box in any of the above situations, as the life of the contacts may otherwise be reduced.

Switch mounting screw 27.6 1.5 Slotted set screw (M2.5 x 4l) 2.5 Use a contact protection box in any of the above situations, as the life of the contacts may otherwise be reduced.

Hexagon socket head bolt (M3 x 4L) Auto switch Auto switch mounting bracket Auto switch mounting nut Note 1) The torque for tightening the hexagon socket head bolt (M2.5 x 9L) is 0.2 to 0.3 Nm. Note 2) The torque for tightening the hexagon socket head bolt (M3 x 4L) is 0.5 to 0.7 Nm. Auto Switch Mounting Bracket Part No.

(656) (151) 0.5 0.4 0.45 (654) (143) 0.4 0.3 0.35 0.3 (650) (133) 0.2 0.25 0.2 (646) (120) 0.15 0.1 0.1 0.05 VXK211l 2 5 10 15 VXK2l2l 3 5 10 15 20 25 30 VXK2l3l 4.5 10 15 20 30 40 50 60 3 2 VXK 4l 6 30 60 3 2 VXK 50 8 25 30 Flow rate Q kg/h ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) How to read the graph The sonic range pressure to generate a flow rate of

+ 4l/-\lF 4t/-t-\lF .-tff ",Jri -T1 'Ti 2 Position 2 Position Single Solenoid Doubl Solenoic ,\ rrn+r\-Tl^ ,.ltzriinll* 4rlJaa+rnr-6 @l/Jril+lru rt l 't1 Base Mounted Type(s Port) i i P a 3 Position 3 Position Closed center Exhaust cnter ^,rrncinw "erqlir'x* 1 l 3 Position Pressure Certer i Porl _-!

+ 4l/-\lF 4t/-t-\lF .-tff ",Jri -T1 'Ti 2 Position 2 Position Single Solenoid Doubl Solenoic ,\ rrn+r\-Tl^ ,.ltzriinll* 4rlJaa+rnr-6 @l/Jril+lru rt l 't1 Base Mounted Type(s Port) i i P a 3 Position 3 Position Closed center Exhaust cnter ^,rrncinw "erqlir'x* 1 l 3 Position Pressure Certer i Porl _-!

Rated flow range of sensor Set flow rate range of sensor Sensor 4L/min 20L/min 40L/min 1.8L/min 0.4L/min Flow rate range 10L/min 0.4L/min 4L/min PF2D504 0.25L/min 4.5L/min 1.8L/min 20L/min PF2D520 1.3L/min 21L/min 4L/min 40L/min PF2D540 2.5L/min 45L/min Flow Rate Characteristics (Pressure Characteristics) PF2D504 PF2D520 PF2D540 0.040 0.035 0.030 0.035 0.030 0.025 Pressure loss [MPa] Pressure

+ 4l/-\lF 4t/-t-\lF .-tff ",Jri -T1 'Ti 2 Position 2 Position Single Solenoid Doubl Solenoic ,\ rrn+r\-Tl^ ,.ltzriinll* 4rlJaa+rnr-6 @l/Jril+lru rt l 't1 Base Mounted Type(s Port) i i P a 3 Position 3 Position Closed center Exhaust cnter ^,rrncinw "erqlir'x* 1 l 3 Position Pressure Certer i Porl _-!

Digital Flow Switch for Deionized Water and Chemicals Digital Flow Switch for Deionized Water and Chemicals Body and sensor Body and sensor New PFA New PFA Tube Tube Super PFA Super PFA Three types of flow range 0.4 to 4l/min (PF2D504) 1.8 to 20l/min (PF2D520) 4.0 to 40l/min (PF2D540) Swept flow characteristics Tapered side seal minimizes dead volume to reduce accumulation of liquid pool

Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.

Cooling capacity (Set temperature 25C and ambient temperature 25C) Approx. 200W Approx. 400W Approx. 510W Approx. 800W Approx. 1000W (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 3L/min) (Flow rate 4L/min) (Flow rate 4L/min) Circulating fluid Water, Ethylene glycol solution up to 20% The compatibility of equipment is the responsibility of the person Tank capacity Approx.1.3L who designs

Hysteresis (Max. value) (mm) Model MDHR2-10 0.3 MDHR2-15 0.2 MDHR2-20 0.6 MDHR2-30 0.3 Auto switch MDHR2 Flat head watchmakers screwdriver Auto switch mounting screw (M2.5 x 4L) 5 to 6 Hysteresis Auto switch operating position (ON) Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw.

Flat head watchmakers screwdriver L MHZ 5 to 6 MHF When auto switch D-M9 is used Switch mounting screw M2.5 x 4l MHL Auto switch MHR MHK L Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6 mm to tighten the auto switch mounting screw. The tightening torque should be about 0.05 to 0.1 Nm.