SMC Corporation of America
Elite Part Number Search
Search Results "SV4000-67-1A"

Unless otherwise indicated, dimensions are the same as Grommet (G). 35 Series VF1000/3000/5000 Pilot Operated 5 Port Solenoid Valve Body Ported/Manifold Dimensions: Series VF3000 (mm) Type 30/VV5F3-30-;;1-;: When the individual EXH spacer (VF3000-75-1A) is mounted.

Applicable manifold base model VP300-25-1A VV3PA3 Blanking plate assembly (With a gasket and two mounting bolts) VP700-25-1A VV3PA7 VP500-25-1A VV3PA5 1569 VPA300/500/700 Series How to Order Valve (With a gasket and two mounting bolts) VPA 3 4 4 1 A Type of actuation A B N.C. (Normally closed) N.O.

A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.

A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.

Note) Electric current should be 1A or less (including the mounted valves).

A 1A () (+) SOL. B 1B () (+) Station 1 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A SOL. A 2A () (+) SOL. B 2B () (+) Station 2 SOL. A 3A () (+) 1.

Switch characteristics Contact point configuration Maximum contact point capacity Operating voltage: AC, DC 1a AC2VA, DC2W 100V or less 12 to 24VAC or VDC: 50mA 48VAC or VDC: 40mA 100VAC or VDC: 20mA Maximum operating current How to Order 30 IS1000M Option X201 X202 Lead wire length: 3m Pressure switch Regulating pressure range: 0.1 to 0.6MPa Lead wire length: 3m; Regulating pressure range

Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

Name Detail Method (Note3, display Detail name 4) 17.1 Board error 1 DB Alarm 17.3 Board error 2 DB 17 Board error 17.4 Board error 3 DB 17.5 Board error 4 DB 17.6 Board error 5 DB 17.8 Board error 6 (Note 5) EDB 19.1 Flash-ROM error 1 DB 19 Memory error 3 (FLASH-ROM) 19.2 Flash-ROM error 2 DB 1A.1 Servo motor combination error DB 1A Servo motor combination error 1A.2 Servo motor control

Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

(If NULL and GAIN are in the shapping condition, 0 to 1A can be viewed by substituting them with command signals 0 to 5V.)

Return to origin . 67 12.1 Return to origin . 67 12.2 Positioning operation . 67 12.3 Pushing operation . 68 (1) Pushing operation is successfully performed . 68 (2) Pushing operation is failed (pushing the air) . 68 (3) Movement of the work piece after the completion of the pushing process . 68 12.4 Controller input signal response time . 69 12.5 Methods of interrupting operation . 69 13

(With spring washer) ( ) 1/8, 1/4 Port 2 (A) VEX1-18-1A Bracket (Option) Port 1 (P), 3 (R) 1/8, 1/4 Mounting hole 2 x 4.5 Hexagon socket head cap screw M3 L = 8 (2 pcs.)

Alarm No.: A.1A Name: Motor combination error Description Incorrect combination of driver and servo motor. Detailed Detailed Name Cause Checking method Result Action display 1A.1 Motor combination error 1) Incorrect combination of Check the model of the servo motor and the combination with the driver. Incorrect combination. Use correct combination. driver and servo motor is connected.

(Example) 2000mm lead wire length Coil 6 10 15 20 25 30 50 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Black(--) Non polarity type ( U) <12V,24VDC only> For DC SYJ3120-5LO-M3 SY100-30-4A-20 For AC SYJ3120-1LO-M3 SY100-30-1A-20 (+)(--) Coil (+)(--) Correctly connect the lead wires to + (positive) and (negative) indications on the connector.

A A Z XB 1A 3 5 Example) VXS2 Z Electrical option Special electrical entry direction With bracket Other option 221 VXS Series Installation options (Mounting option/Special electrical entry direction) The following shows combinations that can be selected using installation options.

RY (Relay): Rated contact load 24V DC, 1A or more, A contact When the AC power supply (100V AC or single phase 200V AC) is shut off, use a relay to shut off 24V DC. Note) In case of the standard Series LTF product. Caution Danger 1. A regenerative absorption unit is required depending on actuator operating conditions.

RY (Relay): Rated contact load 24VDC, 1A or more, "A" contact VAR (Varistor): Equivalent to NEC NV082D07 Note) For standard type electric actuators Caution Danger 1. A regenerative absorption unit is required depending on actuator operating conditions. Read the instruction manual for the regenerative absorption unit when one is connected. 1.