Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.
40 85 20 20KJlD 25 17 45 70 Single knuckle joint Accessory Data GKM20 10 50 100 Double knuckle joint JA-Floating joint 20 10 50 70 Rubber cushion Air cushion ( ): In the case of air cushion Calculation: (Example) C85N10-50, C85F10 Basic weight 49 (10)g Additional weight 3.2/10 mm of stroke Cylinder stroke 50 mm Mounting bracket 12g 49 + 3.2 x 50/10 = 65g 65 +12 = 77g Non-rotating rod: Double
N.O. 13.5 SYA 12 NC 26.2 65.2 58.2 3R 58.2 27 50 50.1 65.2 SYJA 1P 26.2 NO 12 VZA 1/4 1(P), 3(R) port 1/8 (Pitch) P = 27.5 12(PA) port 28 M5 x 0.8 (Breathing hole) VFA 7.5 L2 L1 VFRA (Station n) (Station 1) 1/8 12(PA) port VPA4 12 SYJA 73.5 54 VZA 37.5 11 2A 2A VTA 1/4 2(A) port (Pitch) P = 27.5 28 VGA 2 stations 83.5 68.5 111 96 138.5 123.5 166 151 193.5 178.5 221 206 248.5 233.5 276 261
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
block assembly (Standard): SX3000-51-2A The following columns shall be filled in by SMC.
(Valve) SYJ300-10-2A .1 pc.
60 50 100V AC Hz 110V AC Hz 200V AC Hz 220V AC Hz Closed center Exhaust center Pressure center 60 50 60 M5 X 0.8: 1.8(0.1) 50 60 (1) AC Push-turnlocking slotted style With light and surge voltage suppressor SYJ5000 Rc(PT)1/8: 4.5(0.25) SYJ7000 Rc(PT)1/8, 1/4: 12.6(0.7) Note 1) All AC voltage models have built-in surge voltage suppressor. 1.2-2 Series SYJ3000/5000/7000 Manifold Variations
/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC
/60 Hz L plug 25 2500 mm LN Without lead wire 2 200 VAC 50/60 Hz connector 30 3000 mm LO Without connector 110 VAC 50/60 Hz 50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.
B (+) () 1B 1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM SOL. A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B COM 10A 9A 8A 7A 6A 5A 4A 3A 2A 1A (+) () 2A 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 2 SOL. B (+) () 2B SOL. A (+) () 3A Station 3 SOL. B (+) 3B () SOL. A (+) 4A () Station 4 SOL. B 4B (+) () SOL. A (+) () 5A Station 5 SOL. B (+) 5B () SOL. A (+) () 6A Station 6 SOL. B 6B (+) () SOL.
1.19 7/16-20 7/16-20 73.7 mm 53.0 mm 19.0 mm 30.2 mm UNF-2A UNF-2A B Hex 2 Hex 1 PS610503-6-6 3.11 2.18 .88 1.31 9/16-18 9/16-18 78.9 mm 55.2 mm 22.2 mm 33.3 mm UNF-2A UNF-2A Port 2 PS810503-8-8 3.34 2.38 1.12 1.50 3/4-16 3/4-16 84.9 mm 60.3 mm 28.6 mm 36.5 mm UNF-2A UNF-2A Port 1 PS810503-10-10 3.50 2.48 1.12 1.50 7/8-14 7/8-14 88.9 mm 62.9 mm 28.6 mm 36.5 mm UNF-2A UNF-2A PS1210503-12-
Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.
GA pin CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com KK UNF 2A KK UNF 2A FF UNF 2A D across flats NN mounting nut (included) D across flats LB + ZC per 1" of stroke MB LB + ZC per 1" of stroke NN mounting nut (included) NN UNF 2A (in) MB1 Bore size (in) MM KK
Series: 3 (VQZ300), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: Y (DIN Terminal), Manual Override: B (Locking Slotted Style), IP65 Compliant: W (IP65 Compliant), 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 2 (Metal Seal N.O.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 3 (Rubber Seal N.C.), Function: R (External Pilot), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 1 (Metal Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: YZ (DIN Terminal w/Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)
Series: 3 (VQZ300), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 3 (110VAC 50/60HZ), Lead Wire: LO (L Plug w/o Connector), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: 03T (Base Mounted w/Sub-plate NPTF3/8)