D-A5/A6/A59W/F5/J5 D-F5W/J59W/F5NTL/F59F D-A3/A44/G39/K39 D-B5/B64/B59W/G5/K59 D-G5W/K59W/G59F/G5NTL CC BT-04 BT-04 BT-06 BT-08 BT-08 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M RB BA-04 BA-05 BA-06 BA-08 BA-10 D-A3C/A44C/G39C/K39C BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 J D-Z7/Z80/Y59/Y69/Y7P D-Y7PV/Y7W/Y7WV BA4-040 BA4-040 BA4-063 BA4-080 BA4-080 DMounting bracket belongs to D-A3C/A44C/G39C
Symbol Mounting Nil Direct mounting Dm DIN rail mounting 18 18 stations 08 8 stations *1 Double wiring: 2-position single, double, 3-position, and 4-position valves can be used on all manifold stations. The use of a 2-position single solenoid will result in an unused control signal.
KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 20.5 22 16 18 20.5 22 32 35 39 43 32 35 39 43 6 8 10 12 6 8.5 10 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.
x n + 70 3 199 211 L L1 L2 L3 (MP) L3 (AP) 242 254 428.5 470 285 297 471.5 513 328 340 514.5 556 371 383 557.5 599 414 426 600.5 642 457 469 643.5 685 500 512 686.5 728 L3 = 43 x n + 256.5 L3 = 43 x n + 298 L2 = 43 x n + 82 385.5 427 (External pilot port) 2-Rc 1 8 6-Rc 1 2 3-8-82 83 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Series VFS4000 Plug-in type, Non plug-in
ZP32B B32 32 34 4 15 24.5 29 18.9 37 14 ZP40B B40 40 43 7 18 29.2 34 24.4 48 16 D I M E N S I O N S ZP VA C U U M PA D S ZP50B B50 50 53 7 18 33.2 38 32.4 57 19 H O W T O O R D E R ZP V A C U U M P A D S ZP F L AT T Y P E PA D W I T H R I B P A D D I A M E T E R P A D M AT E R I A L Part No Type A C B D E F Y 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 N Nitrile Rubber
The following shows an example of internal connection diagram of the point table method. 16 43 16. POSITIONING MODE Servo amplifier driver (Note 4) CN1 24 V DC Approx. 46 DOCOM CN1 6.2 k SON 15 16 47 DOCOM MD0 22 CPO RA ST1 17 ST2 18 23 ZP (Note 3) DI0 19 24 INP (Note 3) DI1 41 EM2 42 25 MEND LSP 43 Approx.
Blanking plug KQ2P04 06 08 It is inserted into an unused cylinder port and SUP/EXH ports. Purchasing order is available in units of 10 pieces. Dimensions A L D Model Applicable fittings size d KQ2P-04 KQ2P-06 KQ2P-08 4 6 8 32 35 39 6 8 10 16 18 20.5 DIN rail mounting bracket VVQ2000-57A-4 When ordering assemblies incorporated with a manifold, add suffix -D to the manifold no.
2004 3507 4010 10 to 16 (Thin section series) 15 (11) except 2, 4 15 (11) except 2, 4 15 (11) 15 33 (26) 31 (27) ZPY10 33 (25) 32 (25) 33 (25) 32 (25) 33 (25) 33 () (25) ZPY13 38 (27) 32 (27) ZPY16 ZPY20 38 (30) (30) 38 (29) 38 (30) (30) 38 (29) 38 (30) (30) 38 (28) 38 (30) (30) 38 (29) ZPY25 ZPY32 47 (34) 43 (36) 44 (38) 46 (33) 42 (35) 48 (35) 44 (37) 47 (34) 43 (36) ZPY40
36.5 42 36.5 43.5 78 88 CH2F 41.5 36.5 41.5 36.5 41.5 76 86 50 CH2H 42 36 42 36 42.5 77 87 CH2E 48.5 43 47 43 50.5 85 95 CH2F 46.5 43 46.5 43 48.5 83 93 63 CH2H 48.5 43 47 43 50.5 85 95 CH2E 58.5 55.5 57 55.5 59 93.5 103.5 CH2F 56.5 55.5 56.5 55.5 57.5 92 102 80 CH2H 59 55.5 57.5 55.5 59.5 94 104 CH2E 66.5 67 66.5 67 69.5 104 114 CH2F 65.5 67 65.5 67 68 102.5 112.5 100 CH2H 67.5 67 67.5
Double wiring Note 1) 08 01 8 stations 1 station Specified layout Note 2) (Available up to 16 solenoids) Note 1) Indicate the sizes on the manifold specification sheet in the case of CM.
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
P.43 KQ2T Use to branch tubing at both 90 angles. 31 A Inch Size One-touch Fittings KQ2 Series Applicable Tubing: Inch Size, Connection Thread: UNF, NPT Oval Type Oval Type Plug-in reducer Different diameter tee Plug Use to connect tubing of reduced size for branching at both 90 angles. KQ2R KQ2T KQ2P P.45 P.43 P.46 Use to change size of One-touch fittings.
40 38 37 36 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 17.6 16.5 15.6 14.8 14.1 13.4 12.8 12.2 11.7 11.3 10.8 10.4 10.0 2250 1125 750 562 450 375 321 281 250 225 204 187 173 160 150 140 132 125 118 112 107 102 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F -8.5 -7.2 -6.0 -5.0 -4.1 -3.3 -2.5 -1.8 -1.2
of 01 to 08 when the suffix 0 is removed, are the same as the solenoid valve model codes.
Refer to pages 2-5-40 to 2-5-43 for control unit.
Also, when exceeding the air cushion stroke ranges on page 8-11-43, the piston speed should be 100 to 200 mm per second. Note 2) The piston speed is 100 to 1000 mm/s for centralized piping. Note 3) Use at a speed within the absorption capacity range. Refer to page 8-11-43.
40 48.5 43 50 43 85 95 80 50 50 55.5 50 56 51 57 51 59 93.5 104 100 59 59 63 59 63.5 58.5 65 58.5 70 104 114 The auto switches listed below cannot be mounted on 63.
AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable related components For details regarding different
(15A) 10 2.4 43 1 2 420 Note) Refer to p.4.0-14 the glossary for detail of max. operating pressure differential and max. system pressure.
L (10) 8 Dimensions (24) (35) Applicable fittings size d 4 Model A L D 10-KQ2P-04 16 32 6 6 10-KQ2P-06 18 35 8 8 10-KQ2P-08 20.5 39 10 10 10-KQ2P-10 22 43 12 12 10-KQ2P-12 24 44.5 14 10-KQ2P-01 16 31.5 5 10-KQ2P-03 16 32 6 10-KQ2P-07 18 35 8.5 10-KQ2P-09 20.5 39 10 10-KQ2P-11 22 43 11.5 5.5 Rail mounting pitch 12.5 0 1 2 3 4 5 6 7 8 9 No.