SMC Corporation of America
Elite Part Number Search
Search Results "RHCL63-500-M9B"

Weight (g) D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.

Basic weight 12.45 (kg) Additional weight 2.23 (kg/100 mm) Cylinder stroke 500 (mm) 12.45 + 2.23 x 500/100 = 23.60 (kg) 3/4 28 to 30 160 3.

Auto switch model Auto switch 40 50 9 4 7 11 63 40 50 63 -X D-A93 D-M9B D-M9BW D-B54 8 3.5 5.5 10 8 4 6.5 10 D-A93 D-M9B D-M9BW D-B54 Note) qBMA2-040 wBJ3-1 Note) qBMA2-050 wBJ3-1 Note) qBMA2-063 wBJ3-1 Individual -X BA-04 BA-05 BA-06 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)

Operating the cylinder by connecting the piping directly to the cylinder can cause the piston speed to exceed the maximum operating speed of 500 mm/s. Therefore, to operate the cylinder, make sure to use an SMC speed controller and adjust the piston speed to 500 mm/s or less. d L (mm) 25 20 32 40 Size 30 29 L 33 36 8 5 d 5 5 Retaining Ring Installation/Removal Caution 2.

Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21

Most sensitive position Most sensitive position 2.7 12.5 12.5 D1799 How to Mount and Move the Auto Switch Mounting Bracket Direct Mounting Style Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L Reed D-A90(V), D-A93(V), D-A96(V) Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V),

Calculation example: CS1L160-500 Basic mass27.57 (Foot style, 160) Additional mass2.39/100 stroke Cylinder stroke500 stroke 27.57 + 2.39 x 500/100 = 39.52 kg Mass/Steel Tube (kg) Bore size (mm) 125 140 180 160 200 300 250 Basic style 15.20 34.16 25.24 18.38 42.66 79.78 115.94 Foot style 16.83 38.36 28.04 20.90 47.54 89.28 133.22 17.88 43.99 31.63 23.38 54.57 146.14 101.62 Rod side flange

Heavy load Standard load Midium load Light load 1 10 50 100 1 0.25 0.49 0.98 1.96 2 20 75 200 2 0.49 0.74 1.47 2.94 3 30 100 300 3 0.74 0.98 1.96 3.92 4 40 125 400 4 0.98 1.23 2.45 4.90 5 50 150 500 5 1.23 1.47 2.94 5.88 6 75 200 600 6 1.47 1.96 3.92 7.84 7 100 250 700 7 1.72 2.45 4.90 9.80 8 300 300 800 8 1.96 2.94 5.88 11.76 9 500 500 900 9 2.21 3.92 7.84 15.68 10 1000 1000 1000 10 2.45

Insulation resistance 50 M or more at 500 VDC (between lead wire and case) 1500 VAC for 1 min. Note 1) (between lead wire and case) 1000 VAC for 1 min.

5000) 8 2 3.2 4.6 2.7 2.8 4 22 500(3000) 4 Most sensitive position 6 2.8 20 2.7 3.2 6 Most sensitive position 22 500(3000) 2.6 9.5 4 Specific Product Precautions Be sure to read before handling.

Operating the cylinder by connecting the piping directly to the cylinder can cause the piston speed to exceed the maximum operating speed of 500 mm/s.

Weight Unit: g D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Caution 0.5 8 8 7 Lead wire length (m) 3 41 41 38 Precautions 5 68 68 63 Fix the switch with the existing screw installed on the switch body. The switch may be damaged if a screw other than the one supplied is used.

Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load Applicable bore size Indicator light Type Special function Electrical entry Wiring (Output) DC AC 20 to 63 80, 100 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line In-line M9NV M9N IC circuit 3-wire (NPN) G59 5 V, 12 V 3-wire (PNP) M9PV M9P G5P Grommet 2-wire 12 V M9BV M9B K59 Connector H7C

500 110 Auto-drains listed on page 95 are attached.

Horizontal Operation (Wall mounting) CY1L40 Model 10 (2.48 1.3 x 103 x ST) = CY3B CY3R 50 Note) Calculate with = 1 for all applications up to 10 300 mmST, 15 500 mmST, 20 500 mmST, 25 500 mmST, 32 600 mmST and 40 600 mmST.

Horizontal Operation (Wall mounting) 12 CY1S40 Model 10 (2.48 1.3 x 103 x ST) = 50 Note) Calculate with = 1 for all applications up to 10 300 mmST, 15 500 mmST, 20 500 mmST, 25 500 mmST, 32 600 mmST and 40 600ST.

, 600, 700, 800 4000 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 40 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

, 600, 700, 800 4000 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 40 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

Bore size (mm) Maximum manufacturable Maximum stroke with switch Standard stroke (mm) stroke (mm) stroke (mm) Symbol Specifications 500 500 150, 200, 250, 300 10 XC57 With floating joint 150, 200, 250, 300, 350, 400 450, 500 15 750 1000 20 1000 1500 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 1500 2000 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 40 2000 1500 Note)