SMC Corporation of America
Elite Part Number Search
Search Results "RDQA50-50M-M9BWVL"

forced lock-release terminal Note3) Cable length Actuator cable: 20m maximum Cooling method Natural air cooling Operating temperature range 0 to 40oC (No freezing) Operating humidity range 90% RH or less (No condensation Storage temperature range -10 to 60oC (No freezing) Storage humidity range 90% RH or less (No condensation Insulation resistance Between the external terminals and case 50M

Enclosure IP40 Operating humidity Operation, Storage: 35 to 85% RH (No condensation) Environmental Withstand voltage 1000 VAC for 1 minute between terminals and housing resistance Insulation 50M or more between terminals and housing resistance (with 500 VDC megger) Temperature characteristics +/2%F.S.

terminal Note3) I/O cable: 5 m maximum Cable length Actuator cable: 20 m maximum Cooling method Natural air cooling Operating 0 to 40oC (No freezing) temperature range Operating humidity 90% RH or less (No condensation) range Storage -10 to 60oC (No freezing) temperature range Storage humidity 90% RH or less (No condensation) range Insulation Between the external terminals and case resistance 50M

Carbon Polyethylene, Polyurethane Piping port size Circulating fluid IN/OUT : Rc1/4 Circulating fluid drain : Rc1/4 Circulating fluid IN/OUT : Rc3/8 Circulating fluid drain : Rc1/4 Power supply voltage Single phase AC100-240V, 50/60Hz Current consumption 8A(100V) to 3A(240V) 10A(100V) to 4A(240V) Inrush current 50A or less Over current protection 15A circuit protector Insulation resistance 50M

Cable length I/O cable: 5m or less Actuator cable: 20m or less Cooling system Natural air cooling Operating temperature range 0 to 40oC (No freezing) Operating humidity range 90%RH or less (No condensation) Storage temperature -10 to 60oC (No freezing) range Storage humidity range 90%RH or less (No condensation) Insulation resistance Between external terminals and case 50M (500VDC) Mass 130

Incremental type) Magnetic field resistance 14.5mT Power supply DC12V10% (Power supply ripple : Less than 1%) Current consumption 40mA Resolution 0.1mm / pulse Accuracy 0.2mm (20) Note1) Output method Open collector (DC35V, 80mA) Output signal Phase A/B phase difference output Max. response speed 500mm/s Withstand voltage AC500V, For one minute (Between case and 12E) Insulation resistance DC500V, 50M

Confirm locations of alert warning and caution labels. 500 500 Voltage interruptions 20ms or less Facility water temp. 10deg.C Insulation resistance 50M or more (DC500V) 0 0 Do not service machinery/equipment or attempt to remove Over voltage category Category II 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 Pollution degree Pollution degree II Circulating fluid temp. deg.C Circulating fluid

I/O cable: 5m or less Cable length Actuator cable: 20m or less Cooling system Natural air cooling Operating temperature range 0 to 55oC *3) (No freezing) Operating humidity range 90%RH or less (No condensation) Storage temperature range -10 to 60oC (No freezing) Storage humidity range 90%RH or less (No condensation) Between external terminals and case Insulation resistance 50M (500VDC) 150g

Read all warning and caution labels carefully and keep them in mind. circuit protector circuit protector Voltage interruptions 20ms or less Insulation resistance 50M or more (DC500V) Do not peel off or rub alert warning and caution labels. Confirm locations of alert warning and caution labels.

Load Load Internal Current Applicable voltage consumption voltage current voltage drop leakage load DC28V 40mA 1.5V D-F8N NPN Type or less or less or less DC24V 100A or DC512 10mA Relay less at 24V or less PLC DC24V (4.5to 28V) IC circuit type 80mA 0.8V D-F8P PNP or less or less DC24V 0.8mA or DC24V 2.5 to 4V D-F8B (DC10 less at Relay 40mA or less to 28V) DC24V PLC Isolation resistance 50M

Solid State Switch Type 1ms or less Operating time 1000m/s Impact resistance Insulation resistance 50M or more at 500VDC (between lead wire and case) D-H7BAL(Example) 61 1000VAC for 1 min.

B B For D-F8 Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch Lm 6 Series CRJ Auto Switch Common Specifications Auto Switch Common Specifications Solid state switch Type 1ms or less Operating time 1000m/s Impact resistance 50M or more at 500VDC (between lead wire and case) Insulation resistance 1000VAC for 1min.

Mounting clearance (mm) Bore size (mm) 40 20 46 25 56 32 Clearance 6 Series CU Auto Switch Specifications Auto Switch Common Specifications Type Reed switch Solid state switch Leakage current None 3-wire: 100A or less; 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s 50M or more at 500VDC (between lead wire and case) 1000m/s Insulation resistance 1500VAC for

With shielding plate 6 8 10 Bore L d 16 3 13.5 0.5 14 0.5 10 Series CUJ Auto Switch Common Specifications Auto Switch Common Specifications Type Solid state switch Operating time 1ms or less Impact resistance 1000m/s Insulation resistance 50M or more at 500VDC (between lead wire and case) 1000VAC for 1min.

Dual-Double Rod Type CXSW 39 Series CXS Auto Switch Common Specifications Auto Switch Common Specifications Type Solid state switch Reed switch Leakage current 3-wire: 100A or less; 2-wire: 0.8mA or less None Operating time 1ms or less 1.2ms Impact resistance 1000m/s2 300m/s2 Insulation resistance 50M or more at 500VDC (between lead wire and case) Withstand voltage 1500VAC for 1 min.

Common Specifications Reed switch Solid state switch Style None 3 wire style: 100 mA or less 2 wire style: 1mA or less Current leakage 1 ms or less (2) 1.2ms Operating time 300m/s2 1000m/s2 Shock resistance 50M or more at 500V DC (Electrical wire, Between bowls) Insulation resistance 1 minute at 1500V AC(1) (Electrical wire, Between bowls) 1 minute at 1000V AC (Electrical wire, Between bowls

Reed switch Type Solid state switch Leakage current 3 wire: 10A or less 2 wire: 1mA or less None 1ms or less Note2) Actuation time 1.2ms Impact resistance 1000m/s{102G} 300m/s{30.6G} Switch operating position (ON) 50M or more with a 500VDC megohmmeter (between lead wire & case) Insulation resistance 1500VAC for 1 minute Note 1) (between lead wire & case) 1000VAC for 1 minute (between lead

Mounting patterne Mounting patternw Auto switch Watchmakers screw driver Mounting screw 5 to 6 (included with the auto switch) 14 Series CY1F Auto Switch Specifications Auto Switch Common Specifications Type Leakage current Reed switch Solid state switch None 3wire: 100A or less, 2-wire: 0.8mA or less Operating time 1.2ms 1ms or less Impact resistance 300m/s2 1000m/s2 Insulation resistance 50M

Internal voltage drop DC () Blue [Black] Leakage current 80mA or less 100A or less at 24VDC 100A or less at 24VDC Red LED lights up when OFF D-F9P, D-F9H Indicator light Red LED lights up when ON Lead wire Oil resistant heavy duty vinyl cord, 2.7, 0.15mm x 3 wire (Brown, Black, Blue [Red, White, Black]), 0.18mm x 2 wire (Brown, Blue [Red, Black]) DC (+) Brown [Red] Insulation resistance 50M

Type Reed switch Solid state switch 3-wire: 100A or less 2-wire: 0.8mA or less Leakage current None Operating time 1ms or less2) 1.2ms Impact resistance 1000m/s 300m/s Auto switch Insulation resistance 50M or more at 500VDC (between lead wire and case) 1500VAC for 1min.1) (between lead wire and case) 1000VAC for 1min.