Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: R06 Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: For Vacuum (0~101kPa), Port Size: R06 Reducer Type, Option: -
Pressure: For Compound Pressure (-101~101kPa), Port Size: R06 Reducer Type, Option: -
Pressure: For Compound Pressure (-101~101kPa), Port Size: R06 Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: For Compound Pressure (-101~101kPa), Port Size: R06 Reducer Type, Option: Sensor Cable
Pressure: For Vacuum (0~101kPa), Port Size: R06 Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: For Vacuum (0~101kPa), Port Size: R06 Reducer Type, Option: Sensor Cable
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JD, PSE5*1 VAC SWITCH 1/8PORT NPT, .47300 lb
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, KD, PSE5*1 VAC SWITCH 1/4PORT NPT, .66138 lb
Compact pressure sensor for pneumatics, Proof pressure: 500kPa, Accuracy (ambient temp. of 25C): 2%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP40, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, 1X, PSE5*1 VAC SW OTHER SIZE(MISC), .15699 lb
. -109No.PS-OMW0012-C Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1
Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa
. -67No.PS-OMU0012-C Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564
ZB-OM00201-B Suction Filter Specifications Filtration rating 30m Filtration area 130 2 Pressure sensor specifications/ ZB1-PS-A Model ZB1-PS1-A ZB1-PS3-A (Sensing part: Standard (PSE543) PSE541 model) Rated pressure range 0 to -101kPa -100 to 100kPa Proof pressure 500kPa Output voltage 1 to 5V DC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, ripple (P-P) 10% at max.
Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563
ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.
ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (P-P) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.
ZB1-PS1-A (PSE541) Rated pressure range Proof pressure Output voltage Output impedance Power supply voltage Current consumption Accuracy Linearity Repeat accuracy Effect of power supply voltage Temperature characteristics 72.5 psi (500 kPa) 1 to 5 VDC Approx. 1 k 10 to 24 VDC10%, Ripple (p-p) 10% or less 15 mA or less 2% F.S.
Body Size: 20 (ΓΈ20mm), Body Material: S (Stainless Steel), Mounting Plate: None, Attachment: w/o Vibration Suppression Cover, Pressure Sensor: S (with Pressure Sensor; Part Number PSE541-M5-X2)
Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL AIR, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JD, PSE5*1 VAC SWITCH 1/8PORT NPT, .21991 lb