Combination Symbol: K2 Combination Symbol: C2 Feature: Single solenoid valve is provided for supply valve. Feature: Adsorption of workpieces and release of vacuum are switched by external pilot valve.
Cylinder port size Symbol Port size C2 With 2 One-touch fitting Note 1) When multiple symbols are specified, indicate them alphabetically. Example) -BKN Note 2) When a back pressure check valve is used only for specified station, specify the back pressure check valve part number, and specify the station number to which the valve is mounted, on the manifold specification sheet.
Weight [g] JXC-C2-1 160 JXC-C2-3 300 JXC-C2-5 480 DIN rail L For 3 Axes For 4 Axes 5.25 12.5 (Pitch) JXC92 JXC73/83/93 7.5 AXT100 DR * For , enter a number from the No. line in the table below.
Correction Factor C2 for Ambient Air Relative Humidity Vc: Actuator volume (mm3) D : Bore size (mm) s : Stroke (mm) Temperature Relative humidity Correction factor C2 Vc = D2s 4 25C 40C 10C 0.2 0.4 0.6 20% Fig. 2 Piping Volume Chart 0.5 1.0 1.3 40% 140 1.0 1.7 2.8 60% 2.1 4.0 5.9 75% 120 6 tube Correction Factor C3 for Supply Pressure Supply pressure (MPa) Correction factor C3 10 Tube volume
(VJ3133) Air operated VJA3130 0.245 0.213 0.194 0.187 0.174 0.184 0.214 K2 K3 C1 C2 C3 C4 Weight includes Bracket B. (Solenoid valve: 24 VDC, M plug connector type) Air operated VJA3130 N.C. (VJ3133) N.C. (VJ3133) Double SOL. (VJ3233-X18) How to Order Refer to page 13-3-34 for further part no. information.
(VJ3133) Air operated VJA3130 0.245 0.213 0.194 0.187 0.174 0.184 0.214 K2 K3 C1 C2 C3 C4 Weight includes Bracket B. (Solenoid valve: 24 VDC, M plug connector type) Air operated VJA3130 N.C. (VJ3133) N.C. (VJ3133) Double SOL. (VJ3233-X18) How to Order Refer to page 13-3-34 for further part no. information.
(Double) Port size C2, C4 (2, 4 one-touch fitting) Mass (g) 31 40 V110-C2/C4 Flow Characteristics Flow characteristics Port size 2a, 2b 1(P)2a/2b C [dm3/(sbar)] C [dm3/(sbar)] 2a/2b3(E) 1(P) b b C2 C4 0.03 0.03 0.22 0.19 0.05 0.05 0.31 0.29 C6 The effective area S (mm2) is approximately 5 times as large as the sonic conductance (S C x 5). 2 3 Port Solenoid Valve Series VV100 Construction
With external pilot specifications (Pitch) P = 10.5 13.5 46.9 18.3 11.8 14.1 8.4 8.6 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 10 19.7 24.6 23 5 3 E 5 3 E 3 5 E 3 5 E 43.2 43 56.5 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 C2 C2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" PE PE X X C1 C1 2 x M12 One-touch fitting [PE: Pilot EXH port] Applicable tubing
Symbol 04 08 Stations 4 stations F: With bracket 8 stations 1/2/3 port size Symbol Port size Barb fitting (Applicable tubing 4/2.5) 40 Connector cable Nil: Without connector cable 2 one-touch fitting C2 C1: With connector cable (Length 300 mm) C2: With connector cable (Length 600 mm) C3: With connector cable (Length 1000 mm) Note) The applicable tube of the barb fitting shows the tube outside
/N.O.) u Coil type C2 C3 C4 C6 C8 Standard With power saving circuit (Continuous duty type) Nil T P P P Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected.
Applicable shaft types: J, K, T C1 = C (mm) D1 L1 max X (mm) D1 = Shaft type Y L2 max D2 Size J K T J K T J K T Size C1 Y = C2 L2 = 50 50 3 to 11.9 X 3 4 to 39.5 4 to 39.5 Y 3 3 to 11.9 63 63 3 to 14.9 X 3 4 to 45 4 to 45 Y 3 3 to 14.9 L1 = D2 = C2 = C X = 80 80 3 to 16.9 X 3 4 to 53.5 4 to 53.5 Y 3 3 to 16.9 100 100 3 to 24.9 X 4 5 to 65 5 to 65 Y 4 3 to 24.9 134 Series CRB1 Rotary Actuator
D-M9AL Bore size (mm) D A B C 6 10 15 20 25 32 19.5 0.5 7.5 11.5 A C 29.5 3 17.5 9 35.5 10 23.5 2 Electrical entry direction: Inward Electrical entry direction: Outward 43 13 31 5 44 15 32 7 53 15.5 41 7.5 Auto switch mounting dimensions (mm) CXSJ6,10 C3 10 Bore size B1 Symbol Auto switch model C2 D2 6 1 1 2 5.5 4 8 6 D1 D-A9 D-M9, D-M9W D-M9AL A1 B1 B1 C1, D1 C2, C3, D2 C1, D1 C2, C3, D2
/N.O.) u Coil type C2 C3 C4 C6 C8 Standard With power saving circuit (Continuous duty type) Nil T P P P Be sure to select the power saving circuit type when a valve is continuously energized for long periods of time. Note the specified energizing time when power saving circuit is selected.
Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Width across flats B3 e ZZ + Stroke 9 Cushion valve Width across flats 1.5 l 9 f h ZZ + Stroke With air cushion One-touch fitting port size P Built-in One-touch fittings H1 H G FZ FY FX FT AL FD ZZ A B1 E F Z B2 C2 H2 I B D K MM N NA NN P S Bore size
Circulating fluid returnT1 8 9 White Blue (CN1) 2 2 (CN2) (CN6) 1/2 Brown Black (CN6) 3/3 1 3 Brown 37 Refrigerator suctionT2 2 4 Black Blue PCB1 Blue 38 Circulating fluid outlet Blue 39 Brown 1 9 Brown (CN1) 2/2 (CN5) 40 Blue 2 13 (CN4) (CN3) 1 2 1 3 11 12 1 3 PCB2 Blue 3 15 PS1 Brown 27 Black Black 20 Blue IFAN Refrigerant high pressure C1 Blue 10 Brown 1 32 Yellow/Green White Black 2 C2
Slim line coupler not shown 5/8 27/32 1 1 C6 C2-SL C2 C4 C8 C6 C3 C1 C5 C2 1/2 C7 C3 1/2 Reducing Couplings not shown Note not shown not shown 1 1/8 7/16 Dia. 3/8 Dia. Typ. 3/8 Dia. 5/16 Dia. Typ. 1/4 Dia.
Please delete the unnecessary part. 1.4-12 Series CM2 Rear Flange (G) CM2G Bore size Stroke (mm) Bore Stroke range A B2 C2 D H2 I AL E F B FD B1 FT FX FY FZ G H H1 0 0.033 0 0.033 0 0.033 0 0.039 1 to 300 13 26 30 5 8 18 8 28 15.5 13 34 7 4 60 20 75 8 41 20 1 to 300 17 32 37 6 8 22 10 33.5 19.5 13 40 7 4 60 25 75 8 45 26 1 to 300 17 32 37 6 8 22 12 37.5 19.5 13 40 7 4 60 32 75 8 45 26
D-F9BAL Bore size (mm) D 18.5 16 -9 -6 -4 -3.5 B 2 9 12 14 14.5 C 0.5 10.5 16.5 24 25 34 A 18.5 28.5 34.5 42 43 52 6 10 15 20 25 32 A C Electrical entry direction: Inward Electrical entry direction: Outward Auto Switch Mounting Dimensions (mm) CXSJ6, 10 C3 Bore size 6, 10 0.4 0.4 7.2 4.8 7.2 4.8 B1 Symbol Auto switch model C2 D2 D1 A1 B1 C1 C2, C3 D1 D2 D-A9 D-F9, D-F9 W,D-M9 C1 A1 D-A9V
Bore size Stroke Head Flange (G): ClM3G R0.5 Effective thread length 2 x FL 4 x FD Mounting hole H2 2 x P 2 x NN G G Width across flats B2 2 x FD Mounting hole Width across flats KA C2 D H1 Corner of the cover I Eh8 FY B MM AL A H Z + Stroke S + Stroke F 1.5 Width across flats B1 Width across flats lNA 20 to 32 FX FZ FT 40 ZZ + Stroke Head Flange (G) (mm) AL 14.5 A 12 B 34 B1 13 B2 26 C2