Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve: ZS-33
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: T (Panel Mount Adapter for w/o Flow Adjustment Valve)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Panel Mount Adapter for w/o Flow Adjustment Valve
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø6 One-touch Fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: ø8 (5/16") one-touch fitting, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication
also on the sensor., Fast response: either 50 ms, 0.5s, 1, or 2s can be chosen., Easy connection and removal of wiring., 2-Color Digital Flow Switch for Air, DIGITAL FLOW SWITCH, 95 lb