Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -
Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Small Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -
Magnet: Built-in, Bore Size: 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 6 Inch, Adjuster: Adjuster Bolt, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -
30 s Switching the signal type of the contact input 1 OFF/RN.ST/ RUN/SW/ RN.ST Switching the signal form of the contact input 1 ALT/MT ALT Contact type switching of contact input 1 A/B A Alarm switching for contact input 1 OFF/WRN/FLT OFF Communication Delay time setting for contact input 1 0600 0 s Setting Menu Chapter 5.8 OFF detection time setting for contact input 1 010 0 s Switching
(6") 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 200 (2") 0050 (1/2"), 0100 (1"), 0150 (1-1/2"), 0200 (2"), 0250 (2-1/2"), 0300 (3"), 0400 (4"), 0600 (6") Double acting Double rod 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 0050 (1/2"), 0100 (1"), 0200 (2"), 0300 (3"), 0400 (4"), 0500 (5") 0600 (6") Single acting Single rod Now available in 8 different
Step Request data Response data Operation details 01 10 0600 000A Alarm history command to clear alarm 14 0 0 0 0 1 01 10 0600 000A history sent. (0 to 10 entries) 0 0 0 0 0 0 01 10 060A 000A Alarm history command to clear alarm 14 0 0 0 2 01 10 060A 000A history sent. (11 to 20 entries) 0 0 0 0 0 0 0 67 - Caution Ensure the alarm history is cleared only after taking corrective action in
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 150 (1 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 150 (1 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl.
Magnet: None, Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: None, Mounting: X (Double Head Side Clevis), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl.
Magnet: D (Built-in), Mounting: X (Double Head Side Clevis), Bore Size: 400 (4"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Above auto switch: D-A73/A80 Refer to p.2.3-116 for auto switch mounting position and mounting height.
Auto switch shown above is D-A73 type and D-A80 type. For the auto switch mounting position and its mounting height, refer to page 7-6-83.
Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.
Auto switch shown above is D-A73 type and D-A80 type. For the auto switch mounting position and its mounting height, refer to page 7-6-83.
across flat B1 H1 NCQ2 Rod End Male Thread C1 X L1 Bore size (mm) X H1 L1 inch 32 40 50 12.7 5/16-24UNF 19.7 Built-in one-touch fittings: 32 to 50 2 x P1 (Piping tube O.D.) 16 3/8-24UNF 23 V 1/2-20UNF 19.5 27.5 C1 dim. not applicable Built-in One-touch Fittings (CQ2 only) Z1 Bore size (mm) Z1 P1 V W1 32 40 50 13 6 36.5 59 13 6 40.5 66 W1 50 16 8 82 Basic Style Auto switch shown above is D-A73
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.
Solid state auto switch: D-H7, D-H7C, D-H7W, D-H7NF, D-H7BA Reed auto switch: D-C7, D-C80, D-C73C, D-C80C, D-A80, D-A9, D-A9V, D-A79W, D-A73 Note 2) The maximum manufacturable stroke of this cylinder is 150 mm for both A and B. 1) Initial state (0 stroke position) Stroke B Stroke A 2) Operation When the air pressure is supplied from the A C B Stroke A port, the rod operates the stroke A.
Applicable Cylinder Series: CDQP2lll-lS/-lT (Axial piping, Single acting) (mm) D-M9l D-M9lV D-M9lW D-M9lWV D-M9lAL D-M9lAVL D-A72/A7lH/A80H D-A73C/A80C/F7l D-F79F/J79/F7lV D-J79C/F7lW D-J79W/F7lWV D-F7BAVL/F7BAL Auto switch model D-A73 D-A80 D-A79W D-A9l D-A9lV D-F7NTL Bore size A B A B A B A B A B 2 A B 7 (11) 6 11 (15.5) 10 3 (7.5) 2 6 (10.5) 5 5.5 (10) 4.5 3 (7) 12 6.5 (8.5) 9 (7) 10.5