 
Magnet: Built-in, Mounting: Rear Pivot, Bore Size: .875in, Stroke: 1", Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in Magnet, Mounting: Rear Pivot Mount, Bore: 7/8", Stroke: 1", Cushion: No Cushion, Rod Boot: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Mounting Options: Rear Pivot Mount w/o Clevis Pin
Magnet: Built-in, Mounting: Rear Pivot, Bore Size: .875in, Stroke: 1", Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: D (Built-in Magnet), Mounting: C (Rear Pivot Mount), Bore: 088 (7/8"), Stroke: 0100 (1"), Cushion: No Cushion, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch)
Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder
Magnet: D (Built-in), Mounting: C (Rear Pivot), Bore Size: 088 (.875in), Stroke: 0500 (5"), Cushion: C (Rubber Bumper), Rod Boot: Without Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: C (Rear Pivot), Bore Size: 088 (.875in), Stroke: 0400, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 7/8", Stroke(mm): 4", Auto Switches: M9P, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 7/8", Stroke(mm): 4", Auto Switches: M9P, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: N/A, Custom-made Specifications: None
Magnet: Built-in, Mounting: Rear Pivot, Bore Size: .875in, Stroke: 5", Cushion: Rubber Bumper, Rod Boot: Without Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rear Pivot, Bore Size: .875in, Stroke: 1", Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Universal, Applicable Tubing: 5/32", Suffix: Required Selection
Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0100 (1"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke: 0100 (1"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: C (Single Clevis), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0100 (1"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)