SMC Corporation of America
Elite Part Number Search
Search Results "NCDJPF10-050D-93A"

Applicable models: D-A73, A73H, A73C, R73, D-97, 93A, A93, A93V, D-A53, A54. MHZ2 rMount a switch at the center of the operating range. MHZJ2 Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON.)

Temp 5 ~ 60OC / 40 ~ 140OF Lubrication Not Required (Pre-Lubricated at Factory) Rod End Thread Male Thread/Without Thread Type Of Mounting Nose, Flange, Foot, Clevis, Trunnion H O W T O O R D E R NCJP P I N C Y L I N D E R-D O U B L E A C T I N G D Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service AUTO SWITCH SPECIFICATIONS L D-90 D-97 D-90A D-93A

D-97.D-93A (|& @D D-93A il ! @ D-90 : lnch D-97 Caution. 1) The abovo dimensions may vary in areas whre magnetic Inlerlerence is present. 2) Fo. 14 stroke cylinder, only one aulo switch may be mounted eithgr on the rod end or the cap end. 3) There are two ways to mounl lhe auto swilches as shown in the above ligure.

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, DC73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

0.99 MPa / 150 PSI Ambient & Fluid Temp 5 ~ 60OC / 40 ~ 140OF Lubrication Not Required (Pre-Lubricated at Factory) Rod End Thread Male Thread/Without Thread Type Of Mounting Nose, Flange, Foot, Clevis, Trunnion H O W T O O R D E R NCJP P I N C Y L I N D E R-D O U B L E A C T I N G D Note: Pre-wired Switches with 3/4 Pin Connectors available AUTO SWITCH SPECIFICATIONS L D-90 D-97 D-90A D-93A

Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, D C 7 3 ( C ) / C 8 0 C , D A 7 3 ( C ) ( H ) / A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.

Applicable model: D-A73, A73H, A73C, A93, A93V, A53, A54, B53, B54, C73, C73C, E73A, Z73, D-R73, R73C, 97, 93A, A33, A34, A33A, A34A, A44, A44A 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed. 1. Keep wiring as short as possible.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PIN, ACTUATOR, NCJP ROUND BODY CYLINDER, EE, 10MM NCJP DBL-ACT AUTO-SW, .16500 lb

Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 15 mm, Rotating Angle: 90 (90°), Vane Type: D (Double Vane), Connecting Port Location: Side Ported, Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Shaft Type: W (Double Shaft with Single Flat), Size: 10 mm, Rotating Angle: 90 (90°), Vane Type: S (Single Vane), Connecting Port Location: Side Ported, Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Size: 10, Rotating Angle: 100 (100°), Vane Type: D (Double Vane), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M

Magnet: D (Built-in Magnet), Size: 15, Rotating Angle: 100 (100°), Vane Type: D (Double Vane), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Electrical Entry/Lead Wire Length: L (3m)

Part No. of Lead Wires with Connectors (Applicable only for connector type) Note 1) Lead wire length Z: 5 m Applicable auto switches Reed auto switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state auto switch: Manufactured upon receipt of order as standard.

Note 1) Lead wire length Z: Auto switches applicable for 5m Reed switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: All models are produced upon receipt of order (standard procedure). However, this does not include D-F9, F9V and F7WV.

Electrical entry Indicator Lead wire Applicable load 3 (L) 5 (Z) AC DC Parallel code 97 12V Yes 24V 93A Cab tire 12V 100V Relay PLC Grommet 2 wire Parallel code 5V 12V 5V 12V 24 V or less 100 V or less 90 IC circuit No 24V 90A Cab tire * Impossible to mount the auto switch on the clevis and trunnion styles. 1.2-1 Pin Cylinder/Single Acting Spring Return Series CJP 6, 10, 15 How to Order A

Applicable models: D-A73, A73H, A73C, C73, C73C, D-97, 93A, A93, A93V, D-A33A, A34A, A44A, D-B53, B54 2) However, in the case of a 2 color indicator type auto switch (D-A79W, B59W), note that the switch will be in a normally ON condition if connections are reversed. Never carry a cylinder by its lead wires.

Magnet: D (Built-in Magnet), Mounting: F (Flange), Size: 10, Rotating Angle: 180 (Single Vane), Vane: S (Single), Auto Switch: 93A--Reed, DC Volt, AC Volt, LED, Horizontal

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.

Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.