SMC Corporation of America
Elite Part Number Search
Search Results "NCDJ2B10-200-C80"

Both directions Lock direction MXW MXP Stroke Bearing Standard stroke (mm) Long stroke (mm) Bore size (mm) MG Model MGP 20 75, 100, 125, 150, 200 250, 300, 350, 400 MLGCM Slide bearing 25 350, 400, 450, 500 MGQ 75, 100, 125, 150, 32 350, 400, 450, 500, 600 MLGCL Ball bushing bearing 200, 250, 300 40 350, 400, 450, 500, 600, 700, 800 MGG * Middle strokes and short strokes other than shown

Bore (mm) Standard stroke (mm) Nylon tarpaulin 60C 110C Neo plain cloth 25, 50, 75, 100, 125, 150, 175, 200, 250, MG 40 Maximum ambient temperature for the rod boot itself. 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, MGP 50, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, MGQ 80, 100 300, 350, 400, 450, 500, 600, 700 MGG Minimum stroke of

Supply voltage Internal voltage drop of switch Minimum operating voltage of load _ > 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (Model D-A6l, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).

The maximum detectable piston speed is: Auto switch operating range (mm) Time load applied (ms) x 1000 V (mm/s) = In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT, M5NT, M5PT) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time.

Stroke Table Long strokes (mm) Max. manufacturable stroke (mm) Bore size (mm) Standard strokes (mm) Note 1) Lock Unlock 20 25, 50, 75, 100, 125, 150, 200 201 to 350 25 301 to 400 32 301 to 450 25, 50, 75, 100, 125, 150, 200, 250, 300 40 1500 301 to 800 50, 63 301 to 1200 80 301 to 1400 Locked condition Unlocked condition 100 301 to 1500 Note 1) Intermediate strokes other than the above are

(When the allowable interval is specified for each cylinder series, use the indicated value.) 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, A80, A80H, A90, A90V, C80, R80, 90, E80A, Z80).

Low Friction: Double Acting Single Rod Series CJ2Q 10, 16 How to Order Bore size 10 16 10mm 16mm Mounting Basic Axial foot Front flange Double clevis Standard stroke (mm) B L F D 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 CJ2Q L 16 60 Standard L 16 60 C73 CDJ2Q With auto switch Number of switches With auto switch (Built-in magnet) 2 1 n S n Auto switch

How to Order Bore size 10 16 10mm 16mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 100 (1"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Cylinder (Tube) Inner Diameter(φ): 3/8", Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): -, Support bracket: Basic, Auto Switches: C80, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1/2", Port Location: In-line, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1", Port Location: In-line, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic, Bore Size: Ø10 (3/8"), Stroke: 1 1/2", Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M, Number: -

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 050 (1/2"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 100 (1"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 150 (1 1/2"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 150 (1 1/2"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 200 (2"), Port Location: R (In-line), Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 (3/8"), Stroke: 300 (3"), Port Location: Perpendicular, Auto Switch: C80--Reed, DC Volt >5 <24, AC Volt <100, Lead Wire, 0.5M