Terminal conduit 12 V Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 24 V Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) Latch type with diagnostic output (2-color indication) 5 V, 12 V IC circuit 4-wire (NPN) P5DW Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 2", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 14", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 4", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 5", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 8", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 12", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 10", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 30", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Rod Trunnion, Bore Size: 3 1/4", Stroke: 1", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Air Cushion: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Air Cushion: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Air Cushion: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, RE, 3.25 INCH NCA1 DBL-ACT AUTO-SW, .00000 lb
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
(Or None in the Case of No Switch), X Option: XC22 (Viton Seals)
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Magnet: Built-in, Mounting: MT1, Rod Trunnion, Bore Size: 3 1/4", Stroke: 12", Air Cushion: Both Ends (Air Cushion), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Viton Seals
Magnet: D (Built-in), Mounting: U (MT1, Rod Trunnion), Bore Size: 325 (3 1/4"), Stroke: 0500 (5"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: B (0 to 2"), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC8 ( Adjustable Stroke, Extension Type)
Magnet: D (Built-in), Mounting: U (MT1, Rod Trunnion), Bore Size: 325 (3 1/4"), Stroke: 0300 (3"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: A (0 to 1"), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC8 ( Adjustable Stroke, Extension Type)