(The capacity of the container should be approx. 10L) Circulating fluid return port Tank lid Circulating fluid outlet Drain port Clip Drain plug Container Normal Liquid discharge Fig. 8-4 Drain the circulating fluid from the product 2. Remove the tank lid. 3. Remove the drain plug on the drain port on the piping to discharge the fluid. An O ring is used for the drain plug.

Purge flow rate should be 5 to 10L/min. The product cannot be sealed completely. Therefore all purge fluid may not come out from purge OUT port. Purge should be applied for prevention of condensation and internal build-up of corrosive gas.

with the M4 tap of Rod cover holding hexagon socket head cap screw Collar holding hexagon set screw Bore size (mm) Recommended tightening torque (Nm) 0.59 to 1.06 0.33 to 0.61 0.59 to 1.06 0.33 to 0.61 2.84 to 5.10 0.59 to 1.06 2.84 to 5.10 1.37 to 2.45 2.84 to 5.10 0.20 to 0.39 0.20 to 0.39 0.20 to 0.39 M3 x 0.5 x L M2.5 x 0.45 x 6L M3 x 0.5 x L M2.5 x 0.45 x 6L M5 x 0.8 x L M3 x 0.5 x 10L

t(s) Charging time for 10l t(s) Pressure increase ratio (P2/P1) Pressure increase ratio (P2/P1) These graphs illustrate the time required to inrease pressure in a closed tank e.g.

MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.6-2 Series MHC2 Double Acting 10, 16, 20, 25 MHC2-10l Note) When signal acting type is used, one side port is bleed port and adjusting needle for finger speed is not attached. When auto switch is used, through hole mounting type is not available.

Applicable auto switch Reed switch Solid state switch I Auto switch mounting screw (M3 X 0.5 X 8l) ISquare nut IAuto switch mounting screw (M3 X 0.5 X 10l) IAuto switch spacer IAuto switch mounting nut ISwitch mounting bracket IAuto switch mounting nut ICross-recessed panhead small screw (M3 X 0.5 X 16l) IHexagon socket head cap bolt (M3 X 0.5 X 14l) 20/25 D-A7, A8 D-A73C, A80C D-A7lH, A80H

t(s) Charging time for 10l t(s) Pressure increase ratio (P2/P1) Pressure increase ratio (P2/P1) These graphs illustrate the time required to inrease pressure in a closed tank e.g.

One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector Valve Unit Series ZYY/ZYX Ejector Valve Specifications Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted ZY3-07S ZY3-07L ZY3-10S ZY3-10L

One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector Valve Unit Series ZYY/ZYX Ejector Valve Specifications Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted ZY3-07S ZY3-07L ZY3-10S ZY3-10L

to 4200 5 R/W Window comparator hysteresis S16 400 Y Setting range 0 to 2200 Setting of OUT1 hysteresis (Window comparator mode) 6 R/W Delay time S16 0 Y Setting range 0 to 6000 Setting of OUT1 delay time OUT1 uses the unit for accumulated output set value (When unit: "L" is selected) 1 R/W Accumulated output set value L S16 0 Y Setting range 0 to 9 Setting range 1, 2L range: -2 to 3 5, 10L

Applicable series AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS-10D AS-20D AS-25D AS-30D AS-40D AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Prepare DIN rail by user. Bracket for AS1002F-02 is not available.

Note Applicable Auto Switches Bore sizes (mm) Reed Switches Solid State Switches Switch mounting screw (M3 x 0.5 x 8l) Square nut DA7, DA80 DA73C, DA80C DA7H, DA80H DA79W DF7, DJ79 DF7V, DJ79C DF7W, DJ79W DF7WV, DF7BA DF7F, DF7NTL 20 BQ 1 Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut 32, 40, 50 63, 80, 100 BQ 2 [Stainless Steel Mounting Screw Kit] The following

Note Applicable auto switches Reed switches Solid state switches Switch mounting screw (M3 x 0.5 x 8l) Square nut Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut D-A7, D-A80 D-A73C, D-A80C D-A7H, D-A80H D-A79W 20 D-F7, D-J79 D-F7V, D-J79C D-F7W, D-J79W D-F7WV, D-F7BA D-F7F, D-F7NTL BQ-1 32, 40, 50 63, 80, 100 BQ-2 [Stainless Steel Mounting Screw Kits] The following

ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Ejector mounting position U D U side D side U side Stations 321 D side [Example] ZZY-JC3N 1 SET ZYY35LZ-10S1-E15C ZYY35LZ-10S1 2 SETS 1 SET 3 Ejector Valve Unit Series ZYY/ZYX Ejector Valve Specifications Series SY3000/SX3000 DIN rail mount type can be mounted in manifold /split base combinations ZY3 07S ZY3 07L ZY3 10S ZY3 10L

Applicable series AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS-10D AS-20D AS-25D AS-30D AS-40D AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Prepare DIN rail by user. Bracket for AS1002F-02 is not available.

Applicable model AS-10L AS1002Fm AS-20L AS2002Fm AS-25L AS2052Fm AS-30L AS3002Fm AS-40L AS4002Fm Part no.

Applicable series AS-10D AS-20D AS-25D AS-30D AS-40D AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Bracket for AS1002F-02 is not available. Prepare DIN rail by user.

View A M12 connector r e y w Pin number q t Specific Product 24 VG342-X87 Dimensions Dual Residual Pressure Release Valve (-X87) VG342(R)-5DZ-10l-S1l-X87 75.3 75 Safety limit switch Made by Rockwell Automation 34 74 Port size: 1/8" (Without check valve) Applicable tube O.D.: 8, 5/16" (With check valve) (External pilot port) Channel 1 Channel 2 Safety limit switch (made by Rockwell Automation

Auto switch mounting Follow the procedures below to mount auto switches. 20 to 100/Direct mount 32 to 100/Rail mount Watchmakers screw driver Auto switch mounting screw (M3 x 0.5 x 10l) Auto switch mounting screw Auto switch spacer Auto switch Auto switch mounting nut Use a tightening torque of 0.5 to 0.7 Nm for auto switch mounting screws.