SMC Corporation of America
Elite Part Number Search
Search Results "MLUB25-25D-F"

Magnet: None, Mounting: B (Basic Style), Size: 25 (Pressure Receiving Area Equivalent to that of ø25 Type), Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 25mm, Rod End: Rod End Female Thread, Locking Direction: B (Retracting Stroke Lock)

Magnet: None, Mounting: Basic Style, Size: Pressure Receiving Area Equivalent to that of ø25 Type, Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 25mm, Rod End: Rod End Female Thread, Locking Direction: Retracting Stroke Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

F = One finger thrust. MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.6-2 Series MHC2 Double Acting 10, 16, 20, 25 MHC2-10l Note) When signal acting type is used, one side port is bleed port and adjusting needle for finger speed is not attached. When auto switch is used, through hole mounting type is not available.

Magnet: None, Mounting: B (Basic Style), Size: 25 (Pressure Receiving Area Equivalent to that of ø25 Type), Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 25mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock)

Magnet: None, Mounting: B (Basic Style), Size: 25 (Pressure Receiving Area Equivalent to that of ø25 Type), Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 125mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock)

Magnet: None, Mounting: B (Basic Style), Size: 25 (Pressure Receiving Area Equivalent to that of ø25 Type), Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 50mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock)

Magnet: None, Mounting: B (Basic Style), Size: 25 (Pressure Receiving Area Equivalent to that of ø25 Type), Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 15mm, Rod End: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock)

Magnet: None, Mounting: Basic Style, Size: Pressure Receiving Area Equivalent to that of ø25 Type, Thread: M Threads (ø25) Rc Threads (ø32, ø40, ø50), Stroke: 25mm, Rod End: Rod End Male Thread, Locking Direction: Forwarding Stroke Lock, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With fall prevention function / With Intermediate Stop Function / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking

MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.5 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M10 x 1.5 4.3 7.4 7.4 17.7 37.2 2.9 5.9 5.9 17.7 37.2 10 12 12 16 20 7 10 10 15 20 Model Applicable bolts Max. tightening torque (Nm) Max. screw-in depth (Lmm) MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D M5 x 0.8 M6 x 1 M6 x

J)3-40DA MHSH(J)3-40DB M50.8 3.2 10 MHSH(J)3-50DA MHSH(J)3-50DB M61 7.3 12 MHSH(J)3-63DA MHSH(J)3-63DB M81.25 18 16 MHSH(J)3-80DA MHSH(J)3-80DB M81.25 18 16 10 MHSJ3MHSH(J)3 MHS2 Nm MHSJ3-16D MHSH3-16D M30.5 0.88 Nm MHSJ3-20D MHSH3-20D M30.5 0.88 MHS2-16D M30.5 0.88 20D M30.5 0.88 MHSJ3-25D MHSH3-25D M30.5 0.88 25D M30.5 0.88 MHSJ3-32D MHSH(J)3-32D M40.7 2.1 32D M40.7 2.1 40D M50.8 4.3 MHSJ3

M8X1.25 12 7 MHL2-25D M8X1.25 17.7 16 MHL2-32D M8X1.25 12 11 MHL2-32D M8X1.25 18 16 MHL2-40D M0X1.5 24 12 MHL2-40D M10X1.5 36 20 Nm MHL2-10D M4X0.7 2.1 MHL2-16D M5X0.8 4.3 MHL2-20D M6X1 7.3 MHL2-25D M8X1.25 17.7 6 - 1. 2. 2 <> AS1200-M5AS2200-01 AS1000AS2000 AS1001FAS2051F 7 - 3-5 Nm MHL2-10D M4X0.7 1.4 MHL2-16D M5X0.8 2.8 MHL2-20D M6X1 4.8 MHL2-25D M8X1.25 12.0 MHL2-32D M10X1.5 24.0

D6 Applicable series AS-10D AS-20D AS-25D AS-30D AS-40D L18 L19 L20 18.2 18.6 22 27.2 28.1 L21 23.2 23.6 27 32.2 33.1 L22 11 12.6 17 22 28 L23 L24 18 19.6 25.8 30.8 36.8 L25 t2 Part no.

40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, IE, 25MM MHZ2, 1.22949 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalDouble actingDouble actingMHZ2-25D