SMC Corporation of America
Elite Part Number Search
Search Results "M-5N"

Passage: FJG (3-Position, Exhuast Center), Solenoid: D (Double), Voltage: 5 (110 VAC, 50/60Hz), Option: N (Indicator Light)

Passage: 3-Position, Closed Center, Solenoid: Double, Voltage: 110 VAC, 50/60Hz, Option: Indicator Light, Seal: -, Subplate: -, Thread: -, Connector: -

Passage: 3-Position, Exhuast Center, Solenoid: Double, Voltage: 110 VAC, 50/60Hz, Option: Indicator Light, Seal: -, Subplate: -, Thread: -, Connector: -

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.15~1

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: [Others] 3 positions perfect, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Exhaust, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.15~1, Driving Type

Type: Solenoid Valves, Application: Unit for Manifold Mounting, Mounting Orientation: Manifold Base, Voltage: AC110V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-PositionExhaust Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa)

A miniature pipe coupling from SMC Corporation.Features· Compact piping space.· Fitting-to-workpiece and fitting-to-fitting connection.

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces

The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces

The ISA series is a non-contact style air catch sensor for applications requiring confirmation of work present for machining operations. Due to the construction of the sensor, fluctuations in the supply pressure does not influence operations. The ISA series is IP66 rated and is dust proof and drip proof. Air catch sensor, Operating pressure: 0.05 to 0.2MPa, Enclosure IP66, Port size: 1/8

The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., Cylinder, Air,

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

The MXJ air slide tables integrated front mounting part and table result in a highly accurate, rigid top and front mounting surface. Clean specification styles are available with no dimensional changes. Several options are available for both the standard and the clean series MXJ. These options include a symmetric style, stroke adjusters, axial piping and auto switches., CYLINDER, ACTUATOR