M3 1 3 mn x g M1E mn x g mn x g M3E M3E x FE x Y FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated using the formulas above.
: Without lead wire D: With connector WO: Without connector cable + + + + H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector + + LN, MN type: with 2 sockets.
M3 1 3 mn x g M1E mn x g M3E x FE x Y M3E FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated using the formulas above.
(Wn) Weight (mn) Y-axis Yn Z-axis Zn X-axis Xn Z X Wa 5 mm 0.88 kg 0 mm 65 mm 111 Wb 42.5 mm 4.35 kg 0 mm 150 mm Y 210 Y Wc 42.5 mm 0.795 kg 111 mm 150 mm Wd 42.5 mm 1.0 kg 210 mm 150 mm n = a, b, c, d 3 Calculation of composite center of gravity m3 = mn = 0.88 + 4.35 + 0.795 + 1.0 = 7.025 kg 1 m3 X = x (mn x xn) 1 7.025 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 1.0 x 150) = 139.4 mm 1
ME M 1 3 mn x g ME mn x g ME x FE x Y ME FE FE Note) Regardless of the mounting orientation, dynamic moment is calculated using the formulas above.
Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.
DOZ is not available. 2 9 Other Option Electrical entry 3 position closed center G: Grommet Lead wire length: 300 mm L: L plug connector With lead wire LN: L plug connector Without lead wire LO: L plug connector Without connector D: DIN terminal 3 3 position exhaust center 4 M: M plug connector With lead wire MN: M plug connector Without lead wire MO: M plug connector Without connector
Cylinder Speed Chart Bore size Series MB, CA2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 500 mm Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 40 50 63 80 100 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 A 500 400 300 200 100 0 1000 900 800 700 600 B 500 400 300 200 100 0 1000
Calculation of Composite Center of Gravity m3 = mn = 0.88 + 4.35 + 0.795 + 0.5 = 6.525 kg 1 m3 X = x (mn x xn) 1 6.525 = (0.88 x 65 + 4.35 x 150 + 0.795 x 150 + 0.5 x 150) = 138.5 mm 1 m3 Y = x (mn x yn) 1 6.525 = (0.88 x 0 + 4.35 x 0 + 0.795 x 111 + 0.5 x 210) = 29.6 mm 1 m3 Z = x (mn x zn) 1 6.525 = (0.88 x 5 + 4.35 x 42.5 + 0.795 x 42.5 + 0.5 x 42.5) = 37.4 mm 4.
: Without lead wire D: With connector LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector H: Lead wire length 600 mm Type LN, MN: with 2 sockets.
: Without lead wire D: With connector WO: Without connector cable L: With lead wire (Length 300 mm) + + + 02: 1/4 With sub-plate + H: Lead wire length 600 mm LN: Without lead wire LO: Without connector MO: Without connector DO: Without connector + Note) R1, R2 port: 1/4 + LN, MN type: with 2 sockets.
150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325 2761 Stroke (In Inches and Hundredths of Inches) Bore 150 200 250 325 400 Note: Quantity is one piece.
, 275, 300 (CXWM16 to 25) 225, 250 (CXWM32) 225, 250, 275 (CXWL16 to 25) 225 (CXWL32) CXWM 16, 20, 25, 32 25 to 200 CXWL 16, 20, 25, 32 225, 250, 275 25 to 200 ML1 25, 32, 40 1001 to 2000 100 to 1000 CY3B 20, 25, 32, 40 2001 to 3000 100 to 1000 CY1B 50, 63 From 2001 200 to 2000 2001 to 4000 (25, 32) 2001 to 5000 (40) 2001 to 6000 (50, 63) REA 25, 32, 40, 50, 63 200 to 1000 (5), 10, 15, 20
300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Applicable auto switches Lead wire length (m) Auto switch model no.
197.9 17 13 260.5 250 208.4 11.5 14 273 262.5 218.9 12.5 15 285.5 275 229.4 13.5 16 298 287.5 239.9 14.5 L1 L2 L3 L4 Note) The width of type E (Matsushita Electric Works) and type G (Rockwell Automation) SI units is 24.3mm greater.
The intermediate strokes that do not use a spacer are made to order "XB10" shown on p.5.4-1. 125, 150, 175, 200, 250 MGP 10, 20, 30, 40, 50, 75, 100 12 16 M L MXS 20 25 MGP 20, 30, 40, 50, 75,100, 125, 150, 175, 200 M L 250, 300, 350, 400 MXQ 32 40 50 63 80 100 MXF MGP 25, 50, 75, 100, 125, 150, 175, 200 M L 250, 300, 350, 400 MXW OUT IN MXP Theoretical Force (N) MG Rod diameter (mm) Operating
Standard Stroke Bore size (mm) Standard stroke (mm) 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Max.
KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 O.D.
, 320, 400, 500 40 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 100 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Intermediate strokes are available.
(Mnpls.) 990 Lone Oak Road, Suite 162 Eagan, MN 55121 Tel: (651) 688-3490 FAX: (651) 688-9013 SMC Pneumatics lnc. (Columbus) 3687 Corporate Drive Columbus, OH 43231 Tel: (614) 895-9765 FAX: (614) 895-9780 SMC Pneumatics Inc. (Rochester) 245 Summit Point Drive Henrietta, NY 14467 Tel: (716) 321-1300 FAX: (716) 321-1865 SMC Pneumatics lnc.