Accuracy: Basic, Motor Mounting Position: In-Line, Motor Type: T8 [AC Servo Motor, (Absolute Encoder), 400W], Lead: 10mm, Stroke: 400mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Cable Type: -, Cable Length: -, Driver Type: -, I/O Connector: -
Accuracy: Basic Type, Size: 63, Motor Mounting Position: Top Mounting, Motor Type: Mounting Type T, Lead Screw: B [LEY25, 6mm; LEY32, 8mm, (10); LEY63, 10mm], Stroke: 400mm, Dust/Drip Proof: Size 25, 32: w/o Enclosure; Size 63: IP5x, Dust Proof Specification, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange
Magnet: None, Mounting: Basic, Bore Size: 63mm, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Mounting: Basic, Bore Size: 80mm, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: NPT, Stroke: 400mm, Low Friction Direction: Pressure at Head Side, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Environment, Applications: Standard, Cushion: Air cushion, Specification: With built-in magnet and switch rail, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Magnet: None, Series: Standard, Mounting: Basic Style, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø40, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Basic Style, Low Friction: Low Friction, Tube Material: Steel Tube, Bore Size: Ø40, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Double Clevis, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø80, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: None, Series: Standard, Mounting: Axial Foot, Low Friction: Low Friction, Tube Material: Steel Tube, Bore Size: Ø50, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Series: Standard, Mounting: Rear Flange, Low Friction: Low Friction, Tube Material: Aluminum Tube, Bore Size: Ø63, Port Thread: Rc, Stroke: 400mm, Low Friction Direction: Head Side at Pressure, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
Table Accuracy: Basic Type, Max. Rotating Torque: K (High Torque, 10 N▪m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: R1 (1.5m), Controller: C91 (Ether Net/IP™), Mounting: 7 (Screw Mounting)