SMC Corporation of America
Elite Part Number Search
Search Results "LEY32A-500B-AP"

AP: Number of pulses per motor revolution AL: Moving distance per motor revolution AM: Unit scale factor Driver QD75 Servo amplifier AP CMX Command Deviation value counter Command pulse AL AM Control CDV unit Electronic gear Feedback pulse Electronic gear Servo motor For example, if 100 (1000[pulse/rev]) is set to parameter No.

Cutout window View A-A' Mounting Standard Stroke GK BP A AA AB AG AH AI AJ AK AL AM AN AO AP B BZ GC GD Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 11 13 75 32 28 54 134 150 108 140 M 8 135 110 4 9 9 104 86.5 15 16 88 37 29 62 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 15 16 88 37 30 62

Note 4) Combination with pressure switch (AP and MP type) is not possible. Note 5) The release valve and the pressure switch on S kit are connected to another power supply. Cable length is 0.6 m.

When the pilot solenoid valves a and b are energized alternately (or when pilot pressure is applied to the P1 and P2 ports of the air operated style alternately), the supplied reduced pressure (RA) can be throttled and exhausted(AP).

Control unit type (see pages 13 and 14 for details) Control equipment Symbol A AP M MP F G C E Nil Air filter with auto drain Air filter with manual drain Regulator Air release valve Pressure switch Blank plate (air release valve) Blank plate (filter, regulator) Number of manifold blocks required for mounting (stations) 2 2 2 2 2 2 2 1 Manifold Specifications Piping specifications Ports 2

AP: Number of pulses per servo motor revolution AL: Moving distance per servo motor revolution AM: Unit scale factor Servo amplifier AP75P Driver Command value Control unit AP AM AL CMX CDV Deviation counter Command pulse Electronic gear Electronic gear Feedback pulse Servo motor The encoder resolution of the servo motor is 262144 pulses/rev.

Refer to the operation manual for used equipment for details. -54- Pr.2 No. of pulse(s) per rotation(AP) Set the number of pulses required for a complete rotation of the motor shaft. If you are using the LECSS, set the value given as the "resolution per servo motor rotation" in the speed/position detector specifications.

Refer to the operation manual for used equipment for details. -57- Pr.2 No. of pulse(s) per rotation(AP) Set the number of pulses required for a complete rotation of the motor shaft. If you are using the LECSS2-T, set the value given as the "resolution per servomotor rotation" in the speed/position detector specifications.

VAC, DC: 20 mA Plug-in type VVZS2000-14A Non plug-in type IS1000-00-X204 Pressure switch Max. operating current Non plug-in type VS4 Caution Operating voltage Air release valve (Single only) Operating pressure range 100 VAC, DC or less VQ7 When using an air filter with auto-drain or manual override drain, mount the filter vertically. 0.1 to 1.0 MPa EVS How to Order VFN VV5ZS2 1 08 01 5 AP

VQ7 0.1 to 1.0 MPa EVS How to Order VFN VV5ZS3 1 08 01 5 AP D 51F Coil voltage of air release valve Series VZS3000 Manifold Note) How to take out the lead wire of air release valve is the same method as the other valve equipped on the same manifold.

Standard Stroke Bore size (mm) Stroke range (mm) AA AB AC AD AE AF AP A B C D E F G H I J GC GK GL GQ GR 20 12 16 19 100 35 M6 x 1 depth 12 35 75, 100, 125, 150, 200 129 135 29 80 118 6.6 11 depth 8 M10 x 1.5 depth 18 40 73 27 5.5 6 8 4 25 16 19 19 120 40 45 M8 x 1.25 depth 16 75, 100, 125 149 170 29 100 150 9 50 93 14 depth 10 M12 x 1.75 depth 21 34 6.5 9 10 7 32 16 19 19 120 40 45 M8 x

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com AB V AP Y + Stroke Z + Stroke WH (Max.)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com BP Lock port for pressure lock (Plug with breathing hole for spring lock) Y + Stroke Z + Stroke AB AP V CNA CNS CLS CLQ MLGP WH (Max.)

Yes, the parts can be ordered with the part number “LEF-AP□□□-N□” on the bag that came with the LEFS series motorless type electric actuator.
The “Component Parts” table can be found in the “Motor Mounting Parts” section of the LEFS series motorless type electric actuator catalog.
Note 1) The same applies to the LEY-AP□ and LEJ-AP□ of the LEY and LEJ series motorless type.

Thread type Rc Nil Control equipment Symbol A Nil AP M MP F G C E NPTF T G F Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blanking plate (Air release valve) Note) It is not applicable to O n e t o u c h fittings.

www.stevenengineering.com I 5.23 AIR PREPARATION SERIES NAP100 PRESSURE CONTROL VALVE The (N)AP Series pressure relief regulator is an adjustable re l i e f v a l v e w i t h a c o n t ro l r a n g e o f 1 8 ~ 1 0 0 P S I .

Brown: 24 VDC +10%/5% (Valve power supply) 1 White: 0 V (Valve power supply) 2 Made to Order Black: 0 V (Power supply for control/input) (Power supply for input)1 Blue: 24 VDC10% (Power supply for control/input) (Power supply for input)1 3 4 Gray: Ground 5 Cable length 10 mm p. 247 Connections *1 For DeviceNet and CANopen For EtherNet/IP For PROFIBUS DP Straight connector type @6EX500-AP

3 Controller/Driver mounting Screw mounting DIN rail mounting Nil D Nil 6N 6P 1N 1P AN AP Nil 1 3 5 Without cable 1.5 32 Without controller/driver LECP6/LECA6 (Step data input type) NPN PNP NPN PNP NPN PNP DIN rail is not included. Order it separately.

Thread type Rc Nil Control equipment Symbol A Nil AP M MP F G C E NPTF T G F Air filter with auto-drain Air filter with manual drain Regulator Air release valve Pressure switch Blanking plate (Air release valve) Note) It is not applicable to O n e t o u c h fittings.

AP 1/4 INCH STANDARD (PT), AIRLINE EQUIPMENT, AP BP RELIEF REGULATOR, DB, AP 1/4 INCH STANDARD (PT), 0.44092 lb