Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 300mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 3 (3), Controller Option: D (DIN
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 3 (3), Controller Option: D
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 3 (3), Controller Option: D
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 3 (3), Controller Option: D (DIN
Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: 1P (LECP1, Programless Type, PNP), I/O Cable Length for LEC: 3 (3), Controller Option
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Option: DIN Rail Mounting, Communication
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Option: DIN Rail Mounting, Communication
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Option: DIN Rail Mounting, Communication
Table Accuracy: High Precision, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller Type - LEC, JXC: LECP1, Programless Type, PNP, I/O Cable Length for LEC: 3, Controller Option: DIN Rail Mounting,
Oscillation Angle A: 320°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.8, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Standard cable, Actuator cable
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 6.65795 lb, Stroke Model30050060070080090010001200150018002000LEFB25???????????
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 150mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: C (w/1 pc, Included), Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: Housing B, Bottom,
Linear Guide Single Axis Slider, LEM, ELECTRIC ACTUATOR, 5.93000 lb
The LES series electric slide table actuator uses a compactly-integrated, recirculating linear guide for high rigidity and high precision. When the LES is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein.. Two types of built-in motors * are available. The series can be top or bottom mounted. In
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting