(Approx.100L/min) 4.Handle 5.Sealant tape 6.Operation manual (For "-H") (This manual) 6) If air remains in the case, press air release button to *Use this handle only to loosen the discharge the air as necessary. case. Do not use to tighten the case. * When using the filter, the supply pressure should be 0.69 MPa (100 psi) or lower.
(Approx.100L/min) 5. Sealant tape 6. Operation manual 4. NPTxRc adapter x2pc. (This manual) 7) If air remains in the case, press air release button to discharge the air as necessary. * When using the filter, the supply pressure should be 0.65MPa 2.
(Approx.100L/min) 4. Hex nipple x2pc. 5. Sealant tape 6. Operation manual (This manual) 7) If air remains in the case, press air release button to discharge the air as necessary. * When using the filter, the supply pressure should be 0.5MPa 2.
Serial communication Temp: 0 to 40 C Humidity : 35 to 85%RH Altitude : up to 1000m Environment : No corrosive gas, solvent such as thinner and flammable gas Temp :-40 to 70 C (No dew condensation and icing) Humidity : 5 to 95%RH Environment : No corrosive gas, solvent such as thinner and flammable gas Cooling capacity Approx. 22W (Set temperature 23 C and ambient temperature 23 C, flow rate 100L
Air flow capacityNote 1) 100L/min(ANR) 500L/min(ANR) Filtration rating 0.0199.99 MAX Operating pressure 1.0MPa (0.99MPa for Nitrogenat 20 Operating temp. 5 to 45 Initial pressure oss 0.03MPa or less (at primary pressure of 0.7MPa and max. air flow capacity) Clean room (class 100) Note 1) The air flow capacity is the flow rate at a primary pressure of 0.7MPa.
Discharged flow rate: 100L/ min (ANR) or more. If multiple auto drains are used, confirm used compressor has capacity over the result of multiplying the above capacity and the number of used auto drains. {For example, in case of two auto drain, the compressor need the capacity over 1.5kW [200L/ min (ANR)].} Operating pressure: 0.1MPa or more at min..
Discharged flow rate: 100L/min (ANR) or more. If multiple auto drains are used, confirm used compressor has capacity over the result of multiplying the above capacity and the number of used auto drains. { For example, in case of two auto drain, the compressor need the capacity over 1.5kW [200L/min (ANR)]. } Operating pressure: 0.1MPa or more at min..
Discharged flow rate: 100L/ min (ANR) or more. If multiple auto drains are used, confirm used compressor has capacity over the result of multiplying the above capacity and the number of used auto drains. {For example, in case of two auto drain, the compressor need the capacity over 1.5kW [200L/ min (ANR)].} Operating pressure: 0.1MPa or more at min..
Discharged flow rate: 100L/min (ANR) or more. If multiple auto drains are used, confirm used compressor has capacity over the result of multiplying the above capacity and the number of used auto drains. {For example, in case of two auto drain, the compressor need the capacity over 1.5kW [200L/min (ANR)].} Operating pressure: 0.1MPa or more at min..
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L) AIR HYDRO UNITS, CC, CCT, CCV. AIR-HYDRO UNIT. 5.20000 lb. N67.
Discharged flow rate: 100L/min (ANR) or more. If multiple auto drains are used, confirm used compressor has capacity over the result of multiplying the above capacity and the number of used auto drains. { For example, in case of two auto drain, the compressor need the capacity over 1.5kW [200L/min (ANR)]. } Operating pressure: 0.1MPa or more at min..
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs)
Flow Range: 1 (PF2A511: 10-100l/min, PF2A521: 20-200l/min, PF2A551: 50-500l/min), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, OTHERS, CH HYDRAULIC CYLINDER, VD, 160MM CH DOUBLE-ACTING, 32.23486 lb
Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, OTHERS, CH HYDRAULIC CYLINDER, PD, 63MM CH DOUBLE-ACTING, 10.55767 lb