SMC Corporation of America
Elite Part Number Search
Search Results "LEY16DC-100-RA"

CL+ Stroke A + Stroke 44 22 0.1 0.3 Double Clevis Style Stroke range Without auto switch With auto switch Bore size (mm) A B CL A B 101.5 111.5 CL Rod end nut 33.5 125.5 30.5 40.5 115.5 125.5 10 to 50 75, 100 40.5 111.5 50 9-10-21 21 Series CLQ Dimensions: 63, 80, 100 Both ends tapped style: CLQA63/80/100 RA RB 2 x 4-O threads RA RB Basic style (Through-hole): CLQB63/80/100 Extension locking

115.5 125.5 10 to 50 75, 100 111.5 40.5 50 33.5 14 Series CLQ Dimensions/63, 80, 100 Double end tapped: CLQA63/80/100 RA RB 2 x 4-0 threads RA RB Standard type (through hole): CLQB63/80/100 Extension locking LOCK Approx.

115.5 125.5 10 to 50 75, 100 111.5 40.5 50 33.5 14 Series CLQ Dimensions/63, 80, 100 Double end tapped: CLQA63/80/100 RA RB 2 x 4-0 threads RA RB Standard type (through hole): CLQB63/80/100 Extension locking LOCK Approx.

Operating range and hysteresis How to change the auto switch detecting position Auto switch mounting Auto switch adjustment D53 CRB2 Series Volume [cm3] Vane type Single vane Double vane Size 10 15 20 30 40 10 15 20 30 40 Rotating angle 90 180 270 90 180 270 90 180 270 90 180 270 90 180 270 90 100 90 100 90 100 90 100 90 100 Volume 1 (0.6) 1.2 1.5 1.5 (1.0) 2.9 3.7 4.8 (3.6) 6.1 7.9 11.3

Standard type (through hole type)/RQB, RDQB Double end tapped type: RQA, RDQA Double end tapped RA RA mm OA threads Bore size (mm) RA OA 32 40 50 M6 x 1.0 10 M6 x 1.0 10 M8 x 1.25 14 H effective thread depth C 2-P (port size) 4-N through Approx.

Main shaft Double action actuator OUT2 Main shaft Single action actuator X OUT1 OUT2 OUT1 X SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.

Main shaft Double action actuator OUT2 Main shaft Single action actuator OUT1 OUT2 OUT1 SUP The cam of the positioner should be set on the RA surface. SUP SUP The cam of the positioner should be set on the RA surface. The cam of the positioner should be set on the RA surface. IN + IN + IN + OUT1 is plugged.

RB RA RC RF RE RD RJ SC SB SA Model MIS20-30 MIS20-20 MIS20-10 MIS12-30 MIS12-20 MIS12-10 8 6 6 M5 x 0.8 14 18 1.8 2.5 8 24 22.5 12 34 26 2.2 4 12 9 M8 x 1 10.5 11 12 Series MIW/MIS Auto Switch Mounting When mounting an auto switch, insert the switch in the switch mounting groove on the escapement from the bottom.

RB RA RC RF RE RD RJ SC SB SA Model MIS20-30 MIS20-20 MIS20-10 MIS12-30 MIS12-20 MIS12-10 8 6 6 M5 x 0.8 14 18 1.8 2.5 8 24 22.5 12 34 26 2.2 4 12 9 M8 x 1 10.5 11 Series MIW/MIS Auto Switch Mounting When mounting an auto switch, insert the switch in the switch mounting groove on the escapement from the bottom.

Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.

Specifications [Surface finish Ra] Surface finish of the inner surface (wetted parts). A standard for measuring surface roughness which averages the peak to valley of the surface profile over a given distance (stroke). Multiple readings on a part are also averaged for Ra, but for Ra max, the worst reading is the value for that part.

-080-24A 80 36 11 72 85 45 110 CG-100-24A 100 50 12 93 100 60 130 Courtesy of Steven Engineering, Inc. !

-080-24A 80 36 11 72 85 45 110 CG-100-24A 100 50 12 93 100 60 130 Courtesy of Steven Engineering, Inc. !

53.5 74.5 20 4.5 59 7 13 23.5 118 53.5 80 80 43.5 12 63 98 86 22 6 29 71 7 13 137 53.5 100 100 Double clevis (mm) Bore (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 Y LY LZ X W/o auto switch With auto switch A 88 98 109.5 119.5 132 142 Bore (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 CD CL CT CU CW CX CZ L 9 91.5 113 16.2 63 B 36 46

32, 40 5 10 30 51 50 100 101 300 200 5 10 30 51 50 100 101 300 200 Stroke [mm] Stroke [mm] MGPL80/100, MGPA80/100 MGPL80/100, MGPA80/100 50 50 100 100 100 80 100 100 Load mass m [kg] Load mass m [kg] 80 80 80 100 80 10 10 80 5 10 29 30 51 50 300 200 100 5 10 29 30 51 50 300 200 100 Stroke [mm] Stroke [mm] 444 Model Selection MGP Series L L m m Horizontal Mounting Ball Bushing (19) L = 50

40 32 32 32 32 32 32 5 10 20 30 50 40 51 100 101 300 200 5 10 20 30 50 40 51 100 101 300 200 Stroke (mm) Stroke (mm) MGPL80, 100 MGPL80, 100 50 50 100 100 100 80 80 80 100 100 Load weight m (kg) Load weight m (kg) 80 100 80 10 10 80 5 10 100 20 29 30 49 50 300 200 5 10 100 20 29 30 49 50 300 200 Stroke (mm) Stroke (mm) Note: 1 kg = 2.2046 lb 1 in = 25.4 mm 10 Compact Guide Cylinder Series

9 9 80 92 108 75, 100 74 56 M FV 80 10 to 50 73.5 53.5 83.5 63.5 11 11 99 116 134 75, 100 83.5 63.5 100 10 to 50 85 63 95 73 11 11 117 136 154 75, 100 95 73 FT L B + Stroke A + Stroke 4 x FD FX FZ Bore size (mm) Stroke range (mm) L L1 M 63 10 to 50 18 43.5 60 75, 100 80 10 to 50 20 53.5 77 75, 100 100 10 to 50 22 53.5 94 75, 100 L1 Flange bracket material: Carbon steel Surface treatment:

50 75 100 125 40 56 41 23 12.5 25 37.5 50 75 100 125 50 64 51 25 12.5 25 37.5 50 75 100 125 150 63 64 51 25 12.5 25 37.5 50 75 100 125 150 80 68 56 29 12.5 25 37.5 50 75 100 125 150 175 200 100 76 61 29 12.5 25 37.5 50 75 100 125 150 175 200 125 82 75 27 10 20 30 40 60 80 100 120 140 160 180 200 [mm] Rubber Bumper Bore size [mm] h 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301